GLADIUS SMART System manual version 1.4
VFD Display is not functioning properly
A)
Ensure that COM4 is enabled in the CMOS setup, and data is written to COM4 in the
application.
B)
Check if there is any display when system power is ON, if the screen is blank, please
follow the steps below.
B-1)
Make sure the power switch on the VFD display is on before powering the main
system.
C)
Check RJ-45 cable is properly connected to I/O
D)
Check the cable is properly connected to main board
E)
The on-board COM4 I/O chips could be defective.
LAN is not functioning properly
A)
Check if the LAN driver is installed properly. (Please refer to the LAN driver installation)
B)
Check if there are any IRQ conflicts.
C)
Check if the RJ45 cable is properly connected.
D)
The on board LAN chip could be defective.
COM1 and COM2 are not functioning properly
A)
Check if the I/O ports are enabled in the CMOS setup.
B)
Check if there are any IRQ conflicts.
C)
The motherboard could be defective.
Cash Drawer Port is not functioning Properly
A)
Make sure the pin assignment matches between the cash drawer and the RJ11 cash
drawer port.
B)
Verify the digit I/O port address is 284
C)
The motherboard could be defective.
Содержание Gladius Smart
Страница 10: ...GLADIUS SMART System manual version 1 4 GLADIUS SMART Dimension...
Страница 23: ...GLADIUS SMART System manual version 1 4 Step 5 Click Next to continue Step 6 Click Finish to complete setup...
Страница 25: ...GLADIUS SMART System manual version 1 4 Step 4 Click Next to continue Step 5 Click Next to continue...
Страница 28: ...GLADIUS SMART System manual version 1 4 Step 3 Click Next to continue Step 4 Click Finish to complete setup...
Страница 37: ...GLADIUS SMART System manual version 1 4 6 Select Install 7 Click Finish...
Страница 38: ...GLADIUS SMART System manual version 1 4...