nursing homes, and group homes. This is true even if they were once
single family homes.

However, this smoke alarm MAY be used

inside individual rooms as SUPPLEMENTAL protection.

Install a smoke alarm in every room and on every level of the
home.

Smoke may not reach the smoke alarm for many reasons. For

example, if a fire starts in a remote part of the home, on another
level, in a chimney, wall, roof, or on the other side of a closed door,
smoke may not reach the smoke alarm in time to alert household
members. A smoke alarm will not promptly detect a fire EXCEPT in
the area or room in which it is installed.

Interconnected smoke alarms installed in every room and on
every level of the household offers maximum protection.

The

National Fire Protection Agency (NFPA) recommends interconnecting
smoke alarms so that when one smoke alarm senses smoke and
sounds its alarm, all others will sound as well. Do not interconnect
smoke alarms from one individual family living unit to another. Do not
connect this smoke alarm to any other type of alarm or auxiliary device.

Smoke alarms may not alert every household member every
time. 

There may be limiting circumstances where a household

member may not hear the alarm (e.g., outdoor or indoor noise,
sound sleepers, drug or alcohol usage, the hard of hearing, etc.). If
you suspect that this smoke alarm may not alert a household mem-
ber, install and maintain specialty smoke alarms. Current studies
have shown smoke alarms may not awaken all sleeping individuals,
and that it is the responsibility of individuals in the household that
are capable of assisting others to provide assistance to those who
may not be awakened by the alarm sound, or to those who may be
incapable of safely evacuating the area unassisted.

Smoke alarms must not be used with detector guards 

unless

the combination of alarm and guard has been evaluated and found
suitable for that purpose.

Smoke alarms can only sound their alarms when they detect
smoke.

Smoke alarms detect combustion particles in the air. They

do not sense heat, flame, or gas. This smoke alarm is designed to
give audible warning of a developing fire. However, many fires are
fast-burning, explosive, or intentional. Others are caused by care-
lessness or safety hazards. Smoke may not reach the smoke alarm
QUICKLY ENOUGH to ensure safe escape.

Smoke alarms have limitations.

This smoke alarm is not fool-

proof and is not warranted to protect lives or property from fire.
Smoke alarms are not a substitute for insurance. Homeowners and
renters should insure their life and property. In addition, it is possi-
ble for the smoke alarm to fail at any time.

For this reason, you

must test the smoke alarm weekly and replace every 10 years.

SMOKE ALARM PLACEMENT

Invensys Controls Americas recommends complete coverage pro-
tection achieved by installing a smoke alarm in every room of your
home. The National Fire Protection Association’s (NFPA) minimum
requirement, as stated in Standard 72, Chapter 2, reads as follows:

“2-2.1.1.1 Smoke detectors shall be
installed outside of each separate sleep-
ing area in the immediate vicinity of the
bedrooms and on each additional story of
the family living unit including basements
and excluding crawl spaces and unfin-
ished attics. In new construction a smoke detector
also shall be installed in each sleeping room.”

Chapter 2, also reads as follows:

“2-2.2.1 In new construction, where more than
one smoke detector is required by 2-2.1, they
shall be so arranged that operation of any smoke
detector shall cause the alarm in all smoke detec-
tors within the dwelling to sound.”

The NFPA, 1993 Edition, Appendix
A further states:

“The required number of smoke
detectors may not provide reliable
early warning protection for those areas separated by a door from
the areas protected by the required smoke detectors. For this rea-
son, it is recommended that the householder consider the use of
additional smoke detectors for those areas for increased protec-
tion. The additional areas include: basement, bedrooms, dining
room, furnace room, utility room, and hallways not protected by
the required smoke detectors.”

Also, as required by the California State Fire Marshal:

“Early warning fire detection is best achieved by the installation of
fire detection equipment in all rooms and areas of the household
as follows: A smoke detector installed in each separate sleeping
area (in the vicinity, but outside the bedrooms), and heat or
smoke detectors in the living rooms, dining rooms, bedrooms,
kitchens, hallways, attics, furnace rooms, closets, utility and 
storage rooms, basements and attached garages.”

TV ROOM

DINING 
ROOM

KITCHEN

BEDROOM

BEDROOM

BEDROOM

LIVING ROOM

KITCHEN

DINING 
ROOM

BEDROOM

BEDROOM

BEDROOM

LIVING ROOM

BEDROOM

BEDROOM

LIVING
ROOM

DINING
ROOM

BASEMENT

HALL

110-762F English  12/12/06  4:06 PM  Page 2

Содержание ADC

Страница 1: ... removed drained a beep once per minute indicates a drained battery or improperly connected DO NOT use any other kind of battery except as specified in this manual DO NOT con nect this smoke alarm to any other type of smoke alarm or auxiliary device except those listed in this manual DO NOT remove or disconnect battery or turn off AC power to quiet unwanted alarms This will remove your protection ...

Страница 2: ...alarm QUICKLY ENOUGH to ensure safe escape Smoke alarms have limitations This smoke alarm is not fool proof and is not warranted to protect lives or property from fire Smoke alarms are not a substitute for insurance Homeowners and renters should insure their life and property In addition it is possi ble for the smoke alarm to fail at any time For this reason you must test the smoke alarm weekly an...

Страница 3: ... smoke alarm on the basement ceiling at the bottom of the stairwell IMPORTANT SMOKE ALARM PLACEMENT AND EXCEPTION INFORMATION Install a smoke alarm as close to the center of the ceiling as possible If this is not practical mount no closer than 4 inches from a wall or corner Also if local codes allow install smoke alarms on walls between 4 and 12 inches from ceiling wall inter sections Install a mi...

Страница 4: ... National Fire Protection Association Batterymarch Park Quincy MA 02269 Install smoke alarm on a 4 inch octagon or single gang junction box only 1 From back of smoke alarm remove mounting plate To later engage tamper resist feature twist out and set aside one of the pins molded into the plate Both pins are exactly the same 2 Align recessed slots on plate with mounting holes of a 4 inch octagon or ...

Страница 5: ...arm senses smoke and simultaneously sounds an audi ble alarm Blinks once every 10 seconds smoke alarm is quieting an unwanted alarm Blinks 3 times per minute Indicates this unit initiated an alarm in an interconnected system press the TEST button to reset Blinks 4 times per minute Indicates weak or improperly connected battery Interconnected system only OFF another smoke alarm in the network has s...

Страница 6: ...ld sound an alarm within three seconds after any test button is pushed and the tested smoke alarm sounds 3 If smoke alarm does not sound turn off power at main fuse box or circuit breaker and check wiring Retest smoke alarm REPLACE OR RETURN THE ALARM IF THE PUSH TO TEST FUNCTION DOES NOT OPERATE PROPERLY AFTER FOL LOWING THE PROCEDURES OUTLINED ABOVE see REPAIRS on page 7 DANGER If alarm horn sou...

Страница 7: ...longer under warranty have a licensed electrician replace the smoke alarm immediately with a compara ble Firex brand smoke alarm PRACTICE FIRE SAFETY If the smoke alarm sounds its alarm horn and you have not pushed the test button it is warning of a dangerous situation Your immediate response is necessary To prepare for such occurrences develop family escape plans discuss them with ALL household m...

Страница 8: ... WHEN SOLD WITH INVENSYS CONTROLS AMERICAS SMOKE ALARM Invensys Controls Americas warrants to the original consumer purchaser each new smoke alarm to be free from defects in material and workmanship under nor mal use and service for a period of five 5 years from the date of purchase For Invensys Controls Americas smoke alarms sold with an Ultralife U9VL J 9 volt bat tery Invensys Controls Americas...

Отзывы: