MAINTENANCE AND CLEANING 

In addition to weekly testing, this smoke alarm requires yearly battery
replacement and periodic cleaning to remove dust, dirt, and debris.

DANGER: ELECTRICAL SHOCK HAZARD. Turn off

power at main service panel by removing
fuse or switching appropriate circuit
breaker to OFF position before replacing
battery or cleaning smoke alarm.

BATTERY REPLACEMENT 

Always turn off power to smoke alarm before replacing battery.
Replace battery at least once a year or immediately when the low
battery signal sounds once a minute, even though the smoke
alarm is receiving AC power.

Use only the following batteries as replacements in this smoke alarm:

Eveready 216, 522, 1222, Duracell MN 1604 or Ultralife U9VL-J.

WARNING: DO NOT USE ANY OTHER TYPE OF 

BATTERY, EXCEPT AS SPECIFIED IN THIS
MANUAL. DO NOT USE RECHARGEABLE
BATTERIES.

For Models AD, ADC and PAD:

1. Turn off power to smoke alarm at main service panel.

2. Turn smoke alarm counterclockwise to detach from mounting

plate.

3. Gently pull down smoke alarm. Be careful not to separate wire

connections.

4. Pull out power plug from back of smoke alarm.

5. From back of smoke alarm, lift tab to open battery pocket door.

6. Remove battery from pocket. Disconnect and discard drained

battery from battery connector.

7. Connect a fresh, 9-volt battery to connector. The battery will fit

only one way. Be sure battery connector is securely attached
to battery terminals.

8. Place battery into battery pocket.

9. Close battery pocket door.

Push down until it snaps into place.

10. Replace connector plug. Connector will “snap” into place.

Gently tug connector to be sure it is attached properly.

11. Reattach smoke alarm to mounting plate by turning smoke

alarm clockwise until it snaps into plate.

12. Turn on power and test smoke alarm using Push-to-Test button.

For Model FADC:

1. Turn off power to smoke alarm at main service panel.

2. Slide battery door open as shown on page 6 in the installation

section.

3. Remove drained battery from compartment and discard.

4. Install a fresh 9-volt battery.

5. Slide battery door closed.

6. Turn on power and test smoke alarm using Push-to-Test button.

7. Confirm that Red LED is extinguished. If not repeat testing pro-

cedure until it does.

!

9

!

110-658C  3/8/06  1:21 PM  Page 9

Содержание AD

Страница 1: ...ery is weak or improp erly connected Green and red LED indicator s show when the smoke alarm is receiving AC power working under normal operation in alarm or under false alarm control Loud alarm horn 85 decibels at 10 feet sounds to alert you of an emergency This alarm incorporates the internationally recognized horn signal for evacuation During alarm mode the horn produces three short beeps fol l...

Страница 2: ...every level of the home Smoke may not reach the smoke alarm for many reasons For example if a fire starts in a remote part of the home on another level in a chimney wall roof or on the other side of a closed door smoke may not reach the smoke alarm in time to alert household members A smoke alarm will not promptly detect a fire EXCEPT in the area or room in which it is installed Interconnected smo...

Страница 3: ...struction where more than one smoke detector is required by 2 2 1 they shall be so arranged that operation of any smoke detector shall cause the alarm in all smoke detectors within the dwelling to sound The NFPA 1993 Edition Appendix A further states The required number of smoke detectors may not provide reliable early warning protection for those areas separated by a door from the areas protected...

Страница 4: ...eep ing area If a bedroom area hallway is more than 30 feet long install a smoke alarm at each end If there is a basement Install a smoke alarm on the basement ceiling at the bottom of the stairwell Typical Two Story or Split Level Home Install a smoke alarm on the ceiling or wall inside each bedroom and in the hallway outside each sepa rate sleeping area If a bed room area hallway is more than 30...

Страница 5: ...ics or attics which house electri cal equipment like furnaces air conditioners or heaters DO NOT install smoke alarm Near appliances or areas where normal combustion regularly occurs kitchens near furnaces hot water heaters Use specialized smoke alarms with unwanted alarm control for these areas In areas with high humidity like bathrooms or areas near dishwashers or washing machines install at lea...

Страница 6: ...ull household wires through center hole of plate 4 Secure plate to junction box using mounting screws 5 With a small wire connector connect white wire from connec tor plug to white household wire 6 Connect black wire from connector plug to black household wire 7 If interconnection is desired connect yellow wire from connec tor to interconnect wire between smoke alarms See section Interconnecting S...

Страница 7: ...e than 18 interconnected devices DO NOT connect to any other type or model smoke alarm Connect smoke alarms to a single AC branch circuit If local codes do not permit be sure the neutral wire is common to both phases LED INDICATOR S Models AD ADC and PAD feature two separate LED indicators Model FADC features one combined LED indicator The following section explains what condition the LED indicato...

Страница 8: ...oke alarm You may ignite and damage the smoke alarm or your home Test smoke alarms weekly and upon returning from vacation or when no one has been in the household for several days Stand at arm s length from the smoke alarm when testing The alarm horn is loud to alert you to an emergency and can be harmful to hearing Test all smoke alarms weekly by doing the following 1 Observe the green LED A con...

Страница 9: ... careful not to separate wire connections 4 Pull out power plug from back of smoke alarm 5 From back of smoke alarm lift tab to open battery pocket door 6 Remove battery from pocket Disconnect and discard drained battery from battery connector 7 Connect a fresh 9 volt battery to connector The battery will fit only one way Be sure battery connector is securely attached to battery terminals 8 Place ...

Страница 10: ...smoke alarm PRACTICE FIRE SAFETY If the smoke alarm sounds its alarm horn and you have not pushed the test button it is warning of a dangerous situation Your immediate response is necessary To prepare for such occurrences develop family escape plans discuss them with ALL household members and practice them regularly Expose everyone to the sound of a smoke alarm and explain what the sound means Det...

Страница 11: ... sound when button for at least system is tested three seconds after the first unit sounds The alarm sounds different The alarm is operating cor than I m used to It starts and rectly This alarm features stops the internationally recog nized horn signal for evacu ation The horn pattern is 3 short beeps followed by a 2 second pause and then repeats TROUBLESHOOTING DANGER Always turn off power at mai...

Страница 12: ...9 volt bat tery when sold with Maple Chase smoke alarm provided that it is returned with postage prepaid and with proof of purchase date to Maple Chase Company This warranty does not cover damage resulting from accident misuse or abuse or lack of reasonable care of the product This warranty is in lieu of all other express warranties obligations or liabilities THE IMPLIED WARRANTIES OF MERCHANTABIL...

Отзывы: