second while the button is being pushed and the alarm is sounding.
The smoke alarm will stop sounding when you release the button.

2. If your smoke alarm has the False Alarm Control or Safety Light

feature see “SPECIAL SMOKE ALARM FEATURES” for further 
testing information.

3.

IMPORTANT: 

Always test your smoke alarm upon returning from

vacation, or any other time when no one has been in your household
or residence for several days.

4. If a smoke alarm is installed in a mobile home, test the smoke alarm

after you remove the vehicle from storage and before each trip.

!WARNING: 

I

F YOUR SMOKE ALARM DOES NOT RESPOND AS DESCRIBED IN ANY OF THE

ABOVE TESTS

CHECK THAT A GOOD BATTERY IS PROPERLY INSTALLED

. I

F A GOOD BATTERY

IS PROPERLY INSTALLED

PROMPTLY REMOVE THE UNIT

REPACK IT AND RETURN IT FOR REPAIR

OR REPLACEMENT

(

SEE SECTION

“WHERE TO SEND YOUR SMOKE ALARM IF IT

NEEDS SERVICE”).

TAKING CARE OF YOUR SMOKE ALARM

Your smoke alarm has been designed and manufactured to be as main-
tenance-free as possible. Here are a few simple steps you must perform,
in addition to the weekly tests described in the section “WEEKLY TESTING
OF YOUR SMOKE ALARM,” to keep your unit in good working order.

• The smoke alarm should be vacuumed monthly or more often if there

is dust, dirt or kitchen grease that can accumulate. Use a soft brush
or wand attachment and vacuum all slots in the cover and side. FOR
YOUR SAFETY, you must properly clean and maintain your smoke
alarm, since a dirty or malfunctioning unit may fail to alarm or cause
unwanted nuisance alarms.

• If the unit is damaged or fails to operate properly, and you have

checked that a good battery is installed correctly, follow the
directions in the section “WHERE TO SEND YOUR SMOKE ALARM IF
IT NEEDS SERVICE” for return. FOR YOUR SAFETY, DO NOT OPEN
THE SMOKE ALARM AND TRY TO REPAIR IT YOURSELF. While smoke
alarms are economical devices, they contain precision electronic
components that are precisely calibrated. Repair must be done by
the manufacturer.

REPLACING THE BATTERY

The smoke alarm will “beep” once a minute for at least 30 days when the
battery is weak. The battery must 

immediately 

be replaced with a fresh one.

The battery should also be changed if it does not sound an alarm when
tested.

TO REPLACE THE BATTERY:

1. Check if the tamper resist locking pin is installed in the smoke alarm

(see “USING THE TAMPER RESIST LOCKING MECHANISM” section).
If so, pull the pin completely out of the smoke alarm using long-nose
pliers.

2. Remove the smoke alarm from the mounting bracket by twisting

counterclockwise.

3. Replace old battery with a fresh one. If your smoke alarm has a

safety light, the miniature lamp operates on two AA batteries. 
(See recommended batteries below.)

4. Check that battery connections are secure and the battery is

secured in its compartment.

7

110-644  10/5/00  2:17 PM  Page 9

Содержание A

Страница 1: ... 7 8 REPLACING THE BATTERY p 8 USING THE TAMPER RESIST LOCKING MECHANISM p 9 SPECIAL SMOKE ALARM FEATURES p 10 WARRANTY INFORMATION p 10 WHERE TO SEND YOUR SMOKE ALARM FOR SERVICE IMPORTANT INFORMATION ABOUT YOUR SMOKE ALARM Before installing your smoke alarm you must read this entire Owner s Manual This alarm incorporates the internationally recognized horn signal for evacuation During alarm mode...

Страница 2: ... missing dead or put in wrong A SMOKE ALARM WILL NOT SENSE A FIRE WHEN THE SMOKE CANNOT REACH THE ALARM If a fire starts in a chimney wall roof the other side of a closed door or any other isolated area the smoke alarm may not sense the smoke and will not give a warning If you do not have an alarm in the bedroom and sleep with the door closed a fire inside the bedroom may not sound the alarm locat...

Страница 3: ...uired within the family unit Section 2 1 1 1 reads as follows Smoke detectors shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each additional story of the family living unit including basements and excluding crawl spaces and unfinished attics The provisions of 2 1 1 1 represent the minimum number of detectors required by this standard It i...

Страница 4: ...cks the path of the smoke to the alarm Do install a smoke alarm in a room where flammable household chemicals or solvents are stored For example if you keep kerosene paint thinner or certain types of contact cements within your resi dence install a smoke alarm in that room unless not recommended by a situation described in the section WHERE YOU SHOULD NOT INSTALL SMOKE ALARMS Do install smoke alar...

Страница 5: ... you notice the outside walls or ceiling are unusually hot or cold put the smoke alarm on an inside wall WHERE YOU SHOULD NOT INSTALL SMOKE ALARMS Do not install a smoke alarm within close proximity of heating and cooling supply vents or within close proximity of return or fresh air vents Smoke may be blown away from the smoke alarm by the supply vents or could be diffused or reduced by being dive...

Страница 6: ...nd vacuum the openings on your smoke alarm once a month 4 Do not open the smoke alarm or try to repair it For replacement information see the WARRANTY in the Owner s Manual 5 Verify you have the proper number of smoke alarms in your home and the correct location for each one A smoke alarm will not respond well in an incorrect location 6 If your smoke alarm has one or more of these special features...

Страница 7: ...to stay close to the floor and crawl and how to use the alternate exit if a door is hot and should not be opened Decide on a meeting place a safe distance from your house and make sure all your children understand they should go and wait for you there if there is a fire Hold fire drills every six 6 months to make sure everyone even small children know what to do to escape safely Know where to go t...

Страница 8: ...SMOKE ALARM PLEASE FOLLOW THESE DIRECTIONS 1 Unlock and remove mounting bracket from smoke alarm with a counterclockwise twist 2 Place mounting bracket on ceiling or wall in prearranged location and use pencil to trace two opposing hole positions for mounting screws Drill two 1 16 inch holes 3 Use mounting screws provided for attaching to studs or woodwork For plaster or plasterboard you may wish ...

Страница 9: ...e Use a soft brush or wand attachment and vacuum all slots in the cover and side FOR YOUR SAFETY you must properly clean and maintain your smoke alarm since a dirty or malfunctioning unit may fail to alarm or cause unwanted nuisance alarms If the unit is damaged or fails to operate properly and you have checked that a good battery is installed correctly follow the directions in the section WHERE T...

Страница 10: ...or Duracell M15HD MN1500 CAUTION DO NOT USE ANY TYPE OF RECHARGEABLE BATTERIES USING THE TAMPER RESIST LOCKING MECHANISM To make the smoke alarm somewhat tamper resistant a locking pin has been provided in the base of the unit It will help deter a child or other individual from removing the smoke alarm from the bracket See Figure 7 This can be installed by the following directions 1 Remove the bre...

Страница 11: ...ull normal sensitivity If a real fire occurs however and the quantity of smoke reaching the smoke alarm is sufficiently great the unit will sound an alarm The Reduced Sensitivity level is only intended to eliminate nuisance alarms caused by light concentra tions of smoke If additional Reduced Sensitivity time is required push the button again Every time the smoke alarm is tested it will enter the ...

Страница 12: ...OKE ALARM AND TEN 10 YEARS FOR THE ULTRALIFE LITHIUM U9VL J 9 VOLT BATTERY WHEN SOLD WITH MAPLE CHASE SMOKE ALARM FROM PURCHASE DATE Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you IN NO CASE SHALL MAPLE CHASE COMPANY BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMP...