Smoke Alarm
Hearing
Impaired Kit
Technical Specifications
Installation
Ordering Data
191 E. North Avenue
Carol Stream Illinois 60188 USA
Customer Service Telephone 1.800.951.5526
Customer Service Facsimile 1.630.260.7299
[email protected]
www.FireXsafety.com
©2007 Invensys Controls
For Technical Service
Telephone 1.800.445.8299
Facsimile 1.630.260.7243
[email protected]
3505 Laird Road Unit #14
Mississauga Ontario L5L 5Y7 Canada
Customer Service Telephone 1.800.387.7978
Customer Service Facsimile 1.905.828.1265
[email protected]
Invensys
®
, FireX
®
and Quick Connect™ are
trademarks of Invensys plc., its subsidiaries or
affiliated companies.
Side
Views
Mounting
Brackets
Item No.
Kit Includes
Agency Listing
Packaging
41216 Smoke Alarm-
242
Model GC, 499 Relay,
UL
carton
and 240 Strobe
Individual Carton Dimensions
6-5/16" x 5-1/4" x 6-1/2"
Master Carton Quantity
1
Master Carton Dimensions
6-5/16" x 5-1/4" x 6-1/2"
Master Carton Weight
1.30 lbs.
This smoke alarm should be installed in accordance with the NFPA’s
Standard 72 (National Fire Protection Association, Batterymarch
Park, Quincy, MA 02269) and any local codes that apply.
For the AC and AC/DC direct wire smoke alarms, use #18 AWG
minimum solid or stranded wire. When interconnecting, maximum
wire length between any two is 1,500 feet for #18 AWG or 4,000
feet for #14 AWG (20 OHMS loop resistance).
DO NOT connect to any other type or model of heat or smoke alarm.
Connect smoke to a single AC branch circuit. If local codes do not
permit, be sure the neutral wire is common to both phases.
6/07 – 150-1499E
Product Weight
1.3 lbs.
Operating Temperature
40°F to 100°F (4°C to 38°C)
Interconnect Qty.
Up to 6 accessories in addition to 18
alarms. This signaling device can be
used only with the following FireX
smoke, Smoke/CO, and CO alarms: 406
(model G-6), 418 (model G-18), 484
(model PG-40), 5000 and 4618 (model
FADC), 4518 (model ADC), 4418 and
1018 (model AD), 4121 (model GC),
4480 (model PAD), 12000 (model
FADCM), 12400 (model GCM), 10000
(model COE), 10400 (model COEA).
These are low-voltage interconnect
alarms with a yellow interconnect wire.
Electrical Rating
120V AC, 60Hz, 264mA max.
Alarm Point
1.1±0.47%/ft. obscuration
Horn Output
85 decibels at 10 feet
Listing
UL 217
Detection Type
Ionization
Humidity Range
10% to 93% relative humidity
120V AC
Direct Wire
F
I
R
E
4.5"
2.375"
4.5"
4.5"
Smoke Alarm
Strobe
WHITE
WHITE
RELAY
N.C. (RED)
STROBE
COMMON (GRAY)
N.O. (BLUE)
YELLOW
BLACK
WHITE
SMOKE
ALARM
120 V
INPUT
BLACK
WHITE
YELLOW
BLACK
BLACK
WHITE
Shipping Specifications