TO TURN OFF GAS
TO APPLIANCE
1. Push switch into OFF position. The pilot
will remain lit for normal service.
2. Access control knobs.
3. Depress gas control knob slightly and turn
clockwise to OFF. Do not force.
4. Close equipment shutoff valve (see Figure
8, page 9).
OPTIONAL HAND-HELD
REMOTE OPERATION
Note:
Remote control accessory must be pur-
chased separately (see
Accessories
, page 17).
Follow instructions included with the remote
control.
NOTICE: You must light the pilot
before using the hand-held re-
mote control unit. See
Lighting
Instructions
on page 10.
After lighting, let pilot flame burn for about
one minute. Turn control knob to ON posi-
tion. Adjust flame adjustment knob anywhere
between HI and LO. Flip AUTO/OFF/ON
switch to AUTO. Slide the selector switch
to the REMOTE position (see Figure 13).
Note:
The burner may light if hand-held
remote was on when selector switch was last
turned off. You can now turn the burner on and
off with the hand-held remote control unit.
IMPORTANT:
Do not leave the selector switch
in the REMOTE or ON position when the pilot
is not lit. This will drain the battery.
OPERATING APPLIANCE
Continued
Figure 13 - Setting the Selector Switch,
Control Knob and Flame Adjustment
Knob for Remote Operation
Selector Switch in
REMOTE Position
REMOTE
OFF
ON
Piezo
Ignitor
Control Knob
Flame
Adjustment
Knob
Figure 14 - On/Off Hand-Held Remote
Control Unit (HRC100)
Control Button
Turns Burner
On and Off
SPECIFICATIONS
This appliance has been design certified to ANSI
ZZ1.60-2003. CSA 2.26-2003 Decorative Gas
Appliances for Installation in Solid Fuel Burning
Fireplaces by OMNI Test Laboratories.
MVO18VNA AND MVO24VNA
• Variable Rating: 36,000/53,000 Btu/hr
• Gas Type: Natural Gas Only
• Ignition: Piezo
• Manifold Pressure: 3.5" W.C.
• Inlet Gas Pressure (in. of water):
Maximum - 10.5", Minimum* - 5.0"
* For purpose of input adjustment
MVO18VPA AND MVO24VPA
• Variable Rating: 35,000/45,000 Btu/hr
• Gas Type: Propane/LP Gas Only
• Ignition: Piezo
• Manifold Pressure: 10" W.C.
• Inlet Gas Pressure (in. of water):
Maximum - 14", Minimum* - 11"
* For purpose of input adjustment
WIRING DIAGRAM
When Using Remote
Thermopile
To Remote
Receiver
ON/OFF SERIES (MODEL HRC100)
Hold the control button on the hand-held remote
until burner turns on. Hold the control button
again until burner turns off (see Figure 14).
To Lock
press both buttons on hand-held
remote control until light stops flashing. Hand-
held remote control is now locked. If the fire is
on it will be turned off automatically. In the
locked state, the light will not light up when