2581 Installation Instructions
4
PLANNING THE INSTALL
THESE PLANNING STEPS WILL HELP YOU SAVE TIME AND WILL MAKE THE INSTALLATION EASIER.
DETERMINE THE MOUNTING LOCATION FOR THE AIR COMPRESSOR
- Provides ample air flow and is protected from airborne debris and moisture.
- Mount close enough to the ECU to allow Wire Harness connections to reach.
- If using the optional Firestone Air Accessory Mounting Kit, consider the
guidelines above, and follow the kit’s instructions.
DETERMINE THE MOUNTING LOCATION FOR THE ECU
- Mount close enough to the Air Compressor to allow Wire Harness
connections to reach.
- Allow room for Air Line Tubes to connect to the air fittings on the ECU.
- Allow room for the 14-pin ECU connector to connect to the ECU.
- Allow room for the Air Line Tube to run without sharp curves or bends.
- Using supplied fasteners shown in Step 3 is recommended. If no other mounting option is available,
see the sidebar on Step 2 for using the Large Nylon Ties.
- Select a location that is solid and secure on the body or frame of the vehicle, away from any moving parts,
electrical or any other lines.
PLAN INSTALLATION ROUTES FOR WIRING AND AIR LINES
- Make sure the Wire Harness and Air Line Tubes are not exposed to sharp metal edges that can damage them.
- Use supplied Thermal Sleeves on Air Line Tubes when routing near heat sources.
- Use supplied Nylon Ties to secure Air Line Tubes and Wire Harness to the vehicle.
- Make a loop in the Air Line Tube where shown. This creates a water/debris trap that protects the Air Compressor.
- Measure twice, cut once!
TAPE ALL ELECTRICAL CONNECTIONS
- Use electrical tape to appropriately secure and protect all electrical connections.
USING PUSH-TO-CONNECT FITTINGS FOR AIR LINES
Your kit includes Push-to-Connect fittings to connect the Air Line Tubes to hardware.
Use the instructions below when using the Air Line Tubes.
1
Insert end of Air
Line Tube into
air fitting.
2
Push Air Line Tube
into air fitting as
far as possible.
3
Gently pull on
the Air Line Tube
to check for a
secure fit.
4
To remove, push
down collar and
gently pull Air Line
Tube away.
SUP
AS-1
AS-2
EXH
SUP
AS-1
AS-2
EXH
Removal Tip: Use a 1/4
ʺ
, 5/16
ʺ
,
or 6mm open-ended wrench
to push the collar down.