background image

www.ride-rite.com

TROUBLE SHOOTING THE SYSTEM

Display powers up but it will not inflate or deflate

— The red power wire in the wire harness is not connected 

to the battery.

Both sides blink “Hi” & “150” repeatedly and will not inflate or deflate

— Two of the wires for the pressure 

senders are switched. Gray and Violet go to the LF/LR sender. Brown and Green go to the RF/RR sender.

One side blinks “Hi” & “150” repeatedly and will not inflate or deflate but the other side works

— One of the 

wires for the pressure sender on that side is not connected/making contact with the pressure sender.

The compressor runs continuously, while one side deflates and the other side does nothing, and the but-

tons on the controller do not respond

— The colored wires on the pressure senders are connected to the wrong 

pressure sender. Gray and Violet go to the LF/LR sender. Brown and Green go to the RF/RR sender.

Содержание 2491

Страница 1: ...ngs as stated in the sus pension system instruction manual If you are add ing the Light Duty Electronic Air Command kit to an existing air suspension system you will need to deflate the air springs and remove the air line tubing NOTE ON CONNECTING AIR LINE TUBING Cut the air line tubing as squarely as possible To con nect the air line tubing to the fittings push the tubing into the fittings as far...

Страница 2: ...After the button is released the system will inflate or deflate to the set pressure The system may make periodic adjustments to maintain the set pressure The system will not deflate below 5 PSI and will not inflate past 120 PSI If the system pressure is above or below these levels a warning will be displayed To change the display values from PSI to BAR or BAR to PSI press and hold both the up and ...

Страница 3: ...gure A STEP 4 MOUNT THE GAUGE PANEL The gauge panel must be mounted in a dry protected location with a flat mounting surface Install the four Velcro tabs ontp the back of the gauge panel and then firmly place the gauge panel onto the mounting location STEP 5 WIRE HARNESS FOR THE GAUGE PANEL Connect the black wire from the gauge panel wire harness to a suitable ground and the red wire to 12V igniti...

Страница 4: ... and Green go to the RF RR sender One side blinks Hi 150 repeatedly and will not inflate or deflate but the other side works One of the wires for the pressure sender on that side is not connected making contact with the pressure sender The compressor runs continuously while one side deflates and the other side does nothing and the but tons on the controller do not respond The colored wires on the ...

Страница 5: ...tion of the situation a photo s of the issue and your contact information including ship to address WARRANTY COVERAGE The Ride Rite kits components and accessories are warranted against defects in workmanship and materials This warranty does not cover service or labor charges neglect to the product PERIOD OF COVERAGE Ride Rite air springs Lifetime Limited Work Rite load assists 2 Years Limited Spo...

Страница 6: ...improperly applied improperly installed used in racing or off road applications or used for commercial purposes In addition the warranty will not apply to products which have not been maintained and serviced according to the instructions that accompany the air spring assembly The consumer will be responsible for any costs incurred in removing the product from the vehicle and the cost to return the...

Отзывы: