Firesense 60404 Скачать руководство пользователя страница 2

 

 
MAKE SURE THE HEATER PANELS ARE 
FOLDED DOWN BEFORE MOUNTING THE HEATER ON THE UMBRELLA. 
 
1. Remove the heater brace from the heater body by sliding it downward. (Fig. 1) 
 
 
  2.    Place the heater onto an umbrella pole between 
1 inch (25mm) – 2 inches (48mm) in diameter by inserting the pole into the slot. 
(Fig. 2) 
   
3.    Place the heater brace back on by sliding it upward.(Fig. 3) 
4.    Secure the heater to the umbrella pole by turning the tightening screw 
clockwise until the heater is secure on the umbrella pole. 
 
 
5.    Using the wire loop at the end of the heater panel, pull the heater panel up 
until a click is heard. This means that the panel is now locked into position. 

 

NOTE

DO NOT FOLD THE PANELS 

DOWN WITHOUT FIRST PUSHING THE   
LOCKING PIN IN. 
 

 

6

To fold any of the panels down, press   

      the metal locking pin at the hinge of   
      the heater panel, then holding onto the 
      wire loop at the front end of the heater, 
      fold the heater panel down. 
 
 

NOTE: WAIT UNTIL THE HEATER PANELS HAVE ALL COOLED DOWN BEFORE FOLDING THE HEATER 
PANELS DOWN. 
 

7. When any of the heater panels are folded down while the 
unit is on, that panel will shut-off, because on the back of the panel is a shut –off switch so that only two or even 
one heater panel can be used instead of all three panels. 

 
 
 
 
 
 

 
 
 
 
 
 
 
 
 

 
 
 

1.

 

Connect the plug to a 120V/60Hz outlet. 

2.

 

Press the Toggle switch on the unit with the

for 500W of heat. Only one heater 

panel will activate. Press the

●  ●

toggle switch only and two heater panels will 

activate producing 1000W of heat. Press the two toggle switches together to produce 1500W of heat. 

3.

 

To turn off the heater, press both toggle switches downward. 

REMEMBER, portable electric heaters are designed for spot heating or as a supplementary heat source. 
They are not intended to be the main source of heat during the cold months. 
 
Overheat protection shut –off 

If an overheat temperature is reached, the heater will automatically shut off. 
It can only resume operation when the user resets the unit. Inspect and remove any objects on or adjacent to 
the heater that may cause high temperature. 
 
To reset the heater: 
1.

 

Turn the heater off. 

2.

 

Unplug the heater. 

3.

 

After 5-10 minutes, plug the unit in again and operate normally. 

 

Caution:

 You must always take care that there is sufficient distance for safety (at least 3 ft/50cm) 

between the apparatus and the wall or other objects or combustible materials. 
 

Avoid the use of an extension cord. However, if you must use an extension cord, 
the cord should be NO.14 AWG minimum size and rated not less than 1875 W 
 

 
 

IMPORTANT INSTRUCTIONS 

ONLY USE THE UNIT ON A SECURED VERTICAL POLE THAT IS FIRMLY IN PLACE. 
1.

 

READ ALL INSTRUCTIONS BEFORE OPERATING THIS HEATER. 

2.

 

This heater is not intended for use in bathrooms, laundry areas or similar indoor locations where there may 
be moisture. Never place heater where it may fall into a bathtub, swimming pool, or other water receptacle. 

ASSEMBLY

 

OPERATION INSTRUCTIONS

 

FOR YOUR 

SAFETY 

FIG.

 

1

 

Fig. 2 

Fig. 3 

Locking Pin 

4

Отзывы: