8
A. COMBUSTION AIR + SMOKE DRAW
In that the intended use of this product is outdoors, no additional ventilation or air circulation is required.
B. TERMINATIONS
The FireRock Solid Chimney Block system is approved for use with properly sized rain caps, chimney pots, and other decorative
features.
The chimney included in the fireplace package represents the minimum amount necessary for positive draw characteristics.
Due to the conditions surrounding your installation, additional chimney may be required to achieve proper drafting. This
additional chimney height may be achieved by adding additional chimney blocks from your distributor/dealer or by adding 14” ID
prefabricated metal chimney.
This fireplace is designed to work any appropriately sized, UL 103 compliant, metal prefabricated flue system. The metal flue
system manufacturer must offer an Anchor Plate specifically designed for the purposes of attaching the metal flue to the masonry
fireplace. Installation of the chimney must conform to the manufacturer’s installation instructions.
If using a UL 103 listed metal chimney, refer to the metal flue manufacturer for approved chimney caps, shrouds and covers and
rain caps. FireRock does not manufacture these components and therefore defers to the manufacturer’s instructions.
C. BROKEN COMPONENTS
Components that become broken due to poor handling or shipping should be mortared back together providing the breaks or
cracks are clean and original alignment and dimension can be maintained. Components broken into multiple pieces or fragments
must be discarded and replaced. When in doubt about a component’s usability, consult your FireRock distributor or authorized
FireRock representative for advice. You may also call the FireRock Technical Support Desk toll-free at 888.876.1025.
D. GAS LINE APPLICATIONS
The FireRock fireplace may be drilled through with an ordinary masonry drill bit to accommodate a natural gas connection.
This natural gas connection may be used to 1) incorporate an automatic shut-off device and/or 2) comply with the Standard for
Decorative gas appliances for installation in Vented Fireplaces, ANSI Z21.60. The decorative gas appliance should be installed in
accordance with the National Fuel Gas Code, ANSI Z223.
E. LOG LIGHTER
A log lighter can be used with your FireRock fireplace as either a flush mount (installed before the firebrick) or top mount.
FireRock recommends the log lighter be installed by a professional plumber. See manufacturer’s instructions for directions on how
to install.
INSTALLATION CONSIDERATIONS
Only vented gas logs that are listed by ANSI Z21.60 can be used in this fireplace. This fireplace has not been tested with an
unvented gas log set. To reduce the risk of fire or injury, do not install an unvented gas log set into this fireplace.