FireRock 30 inch Outdoor Скачать руководство пользователя страница 3

Framing

 

This

 

product

 

is

 

designed

 

to

 

be

 

either

 

freestanding

 

or,

 

in

 

the

 

event

 

additional

 

dimension

 

is

 

required

 

built

 

out

 

with

 

concrete

 

masonry

 

units

 

(C.M.U.’s)

 

or

 

metal

 

framing

 

material.

  

There

 

is

 

no

 

airspace

 

or

 

clearance

 

distance

 

to

 

C.M.U.’s

 

or

 

metal

 

framing

 

material

 

required.

 

Height

 

Chart

 

 

FIREBOX

 

and

 

SMOKE

 

CHAMBER

  

HEIGHT

             

MINIMUM

 

CHIMNEY

 

HEIGHT

 

MAXIMUM

 

CHIMNEY

 

HEIGHT

 

OVERALL

 

MINIMUM

 

HEIGHT

 

OVERALL

 

MAXIMUM

 

HEIGHT

 

30”

 

52

 

IN

 

2

 

FT

 

12

 

FT

 

6

 

FT

 

4

 

IN

 

16

 

FT

 

4

 

IN

 

36”

 

61

 

IN

 

2

 

FT

 

12

 

FT

 

7

 

FT

 

3

 

IN

 

17

 

FT

 

3

 

IN

 

42”

 

70

 

IN

 

3

 

FT

 

12

 

FT

 

8

 

FT

 

10

 

IN

 

17

 

FT

 

10

 

IN

 

 

Chimney

 

Requirements

 

The

 

chimney

 

included

 

in

 

the

 

fireplace

 

package

 

represents

 

the

 

minimum

 

amount

 

necessary

 

for

 

positive

 

draw

 

characteristics.

  

Due

 

to

 

the

 

conditions

 

surrounding

 

your

 

installation

 

additional

 

chimney

 

may

 

be

 

required

 

to

 

achieve

 

proper

 

drafting.

  

This

 

additional

 

chimney

 

height

 

may

 

be

 

achieved

 

by

 

adding

 

additional

 

chimney

 

blocks

 

from

 

your

 

distributor/dealer

 

or

 

by

 

adding

 

14”

 

I.D.

 

prefabricated

 

metal

 

chimney.

 

In

 

the

 

event

 

prefabricated

 

metal

 

chimney

 

is

 

chosen

 

it

 

must

 

be

 

tested

 

and

 

found

 

compliant

 

with

 

UL

103.

  

It

 

must

 

be

 

installed

 

in

 

accordance

 

with

 

the

 

chimney

 

manufacturer’s

 

instructions

 

and

 

use

 

all

 

necessary

 

parts

 

specified

 

for

 

use

 

with

 

the

 

listed

 

chimney

 

system.

 

Chimney

 

termination

 

must

 

be

 

a

 

minimum

 

of

 

2

 

feet

 

above

 

any

 

combustible

 

structure

 

within

 

10

 

feet

 

of

 

the

 

chimney

 

termination.

 

***WARNING***

 

THIS

 

PRODUCT

 

HAS

 

NOT

 

BEEN

 

TESTED

 

FOR

 

USE

 

WITH

 

A

 

CHASE.

  

TO

 

REDUCE

 

THE

 

RISK

 

OF

 

FIRE,

 

DO

 

NOT

 

INSTALL

 

A

 

CHASE.

 

 

 

Insulation

 

This

 

product

 

is

 

not

 

designed

 

to

 

be

 

“packed”

 

by

 

insulation.

  

In

 

the

 

event

 

air

 

spaces

 

exist

 

between

 

this

 

product

 

and

 

C.M.U.

 

or

 

metal

 

framing

 

construction,

 

do

 

NOT

 

fill

 

these

 

voids

 

with

 

an

 

insulating

 

product.

 

***WARNING***

 

DO

 

NOT

 

PACK

 

AIR

 

SPACES

 

WITH

 

INSULATION

 

OR

 

OTHER

 

MATERIALS

 

Ventilation

 

In

 

that

 

the

 

intended

 

use

 

of

 

this

 

product

 

is

 

outdoors,

 

no

 

additional

 

ventilation

 

or

 

air

 

circulation

 

is

 

required.

 

Отзывы: