hazards. In these circumstances, smoke may not reach the 

unit alarm QUICKLY ENOUGH to ensure safe escape.

8:  Smoke alarms have limitations. This smoke alarm is not 

foolproof and is not warranted to protect lives or property 

from fire. Smoke alarms are not a substitute for insurance. 

Homeowners and renters should insure their lives and 

property. In addition, it is possible for the smoke alarm to 

fail at any time. For this reason, you must test the smoke 

alarm weekly and replace unit every 10 years.

Battery Connections:

Battery Specification:

Rating voltage: DC9V (Carbon Zinc, Alkaline, Lithium 

Battery
Carbon Zinc Battery 

Gold Peak: GP1604S by GPI International (Shenzhen). LTD
Alkaline Battery 

Raymax: 6LR61 by Zhejiang Mustang Battery Co., Ltd; 

Duracell: 6LR61 or MN1604 by Duracell/P&G company; 

Gold Peak: GP1604A by GPI International (Shenzhen). LTD 
Lithium Battery 

EVE: CR9V/P by EVE Energy Co., Ltd.

Replace Battery:

1:  Turn the alarm body counterclockwise and take out the 

alarm body from the bracket (see Diagram 5).

2:  Take out the old battery, connect the new battery to power 

connector, according to Diagram 1.

3:  Fix the battery into battery box, fit alarm body on bracket 

and turn the alarm body clockwise (see Diagram 2). 

4:  Test smoke alarm using test button. The sound pattern is 

3 short beeps - pause 1.5 seconds, repeat it. If there’s no 

sound output, it means that the smoke alarm is faulty or the 

installing operation is wrong, see “troubleshooting” section 

for more information.

Do Not Install Smoke Alarms in the 

Following Places:

1:  Near appliances or areas where normal combustion 

regularly occurs (kitchens, near furnaces, hotwater heaters). 

Use specialised smoke alarms with unwanted alarm control 

for these areas.

2:  In areas with high humidity, like bathrooms or areas near 

dishwashers or washing machines. Install at least 3m away 

from these areas.

3:  Near air returns or heating and cooling supply vents. Install 

at least 1m away from these areas. The air could blow 

smoke away from the detector, interrupting its alarm.

4:  In rooms where temperatures may fall below 5°C or 

rise above 45°C, or in humidity higher than 85%. These 

conditions will reduce battery life or cause a fault with the 

alarm.

5:  In extremely dusty, dirty, or insect-infested areas particles 

may interfere with smoke alarm operation.

Operation:

Testing

Test the unit to ensure proper operation by pressing the Test 

button for at least 5 seconds, this will sound the alarm if the 

electronic circuitry, horn and battery are working. If no alarm 

sounds, the unit has a defective battery or other failure. DO 

NOT use an open flame to test your alarm, you could damage 

the alarm or ignite combustible materials and start a fire.

Diagram 1

Diagram 2

- 2 -