INSTALLATION

3-6

Manual 0-2846

welded end to end for greater lengths.  Locate the rod
as close as possible to the work table.   Install a ground
wire, 1/0 (53,5 mm

2

) or greater, between the ground

rod and the star ground point on the cutting table.

NOTE

Ideally, a properly installed ground rod will have a
resistance of three ohms or less.

To test for a proper earth ground using 115 VAC, refer
to the following diagram.  Ideally, the reading on the
multimeter should be 3.0 VAC or less.

A-02971

+

_

Meter set to
VAC setting

Machine

Earth Ground

Neutral

Line (Hot)

100W

Light Bulb

115 or 230VAC 

WARNING

Use extreme caution. This

test uses live voltage.

115VAC:  3.0 VAC
230VAC:  1.5 VAC

V

~

V

~

VR   COM    A

 Figure 3-6  Ground Testing

2. Increasing the ground rod length beyond 20 - 30 ft

(6,1 – 9,1 m) does not generally increase the effective-
ness of the ground rod.  A larger diameter rod which
has more surface area may help.  Sometimes keeping
the soil around the ground rod moist by continuously
running a small amount of water into it will work.
Adding salt to the soil by soaking it in salt water may
also reduce its resistance.  When these methods are
used, periodic checking of the ground resistance is re-
quired to make sure the ground is still good.

D. Routing Of Torch Leads

1. To minimize RF interference, position torch leads as

far as possible from any CNC components, drive mo-
tors, control cables, or primary power lines.  If cables
have to pass over torch leads, do so at an angle.  Do
not run the plasma control or other control cables in
parallel with the torch leads in power tracts.

2. Keep torch leads clean.  Dirt and metal particles bleed

off energy, which causes difficult starting and in-
creased chance of RF interference.

Содержание Firepower FP-55

Страница 1: ...Operating Manual A 02766 PlasmaCutting PowerSupply Firepower FP 55 April 4 2003 Manual No 0 2846...

Страница 2: ......

Страница 3: ...in this Manual whether such error results from negligence accident or any other cause Printed in the United States of America Publication Date April 4 2003 Record the following information for Warrant...

Страница 4: ...Scope of Manual 2 1 2 02 General Description 2 1 2 03 Specifications Design Features 2 1 2 04 Power Supply Options 2 2 SECTION 3 INSTALLATION PROCEDURES 3 1 3 01 Introduction 3 1 3 02 Site Selection 3...

Страница 5: ...3 5 05 Power Supply Basic Parts Replacement 5 5 SECTION 6 PARTS LISTS 6 1 6 01 Introduction 6 1 6 02 Ordering Information 6 1 6 03 Power Supply Replacement 6 2 6 04 Replacement Parts 6 2 6 05 Optiona...

Страница 6: ......

Страница 7: ...your head out of the welding fume plume Use an air supplied respirator if ventilation is not adequate to remove all fumes and gases The kinds of fumes and gases from the plasma arc depend on the kind...

Страница 8: ...information on how to test for noise see item 1 in Subsection 1 03 Publications in this manual PLASMAARC RAYS PlasmaArc Rays can injure your eyes and burn your skin The plasma arc process produces ver...

Страница 9: ...FOR WELDINGAND CUTTING OF CONTAINERS AND PIPING THAT HAVE HELD HAZARDOUS SUBSTANCES obtainable from the American Welding Society 550 N W LeJeune Rd Miami FL 33126 15 ANSI Standard Z88 2 PRACTICE FOR...

Страница 10: ...z pouvant contenir des l ments reconnu dans L tat de la Californie qui peuvent causer des d fauts de naissance et le cancer La s curit de sant en Californie et la code s curit Sec 25249 5 et seq CHOC...

Страница 11: ...onnes se trouvant sur le lieu de travail Il faut mesurer les niveaux sonores afin d assurer que les d cibels le bruit ne d passent pas les niveaux s rs Pour des renseignements sur la mani re de tester...

Страница 12: ...URIT POUR LE SOUDAGE ET LA COUPE disponible aupr s de l Association des Normes Canadiennes Standards Sales 178 Rexdale Bou levard Rexdale Ontario Canada M9W 1R3 13 Livret NWSA BIBLIOGRAPHIE SUR LA S C...

Страница 13: ...tion standard C22 2 number 60 forArc welding equipment UL Underwriters Laboratory rating 94VO flammability testing for all printed circuit boards used ISO IEC 60974 1 BS 638 PT10 EN 60 974 1 EN50192 E...

Страница 14: ...Firepower whether arising out of contract negligence strict tort or under any warranty or otherwise shall not except as expressly provided herein exceed the price of the goods upon which such liabilit...

Страница 15: ...ed plug and work cable clamp Refer to Section 2 04 for power supply options and ac cessories A 02766 Figure 2 1 Firepower FP 55 Power Supply 2 03 Specifications Design Features A Power Supply Technica...

Страница 16: ...standard Gas Regulator Filter Assembly only 1 Operating Pressure Output 70 psi 4 8 bar 2 Maximum input gas pressure 125 psi 8 6 bar 3 Filter Particulate Type Filter to 20 microns 2 04 Power Supply Opt...

Страница 17: ...in the rear and at least 6 inches 150 mm on each side for clearance Provide sufficient clearance in front of the unit to allow access to the front panel controls min 6 inches or 150 mm CAUTION Operat...

Страница 18: ...may cause double arcing rapid tip wear or even com plete torch failure Contaminants may cause poor cutting performance and rapid electrode wear C Connecting Gas Supply to Unit The gas supply is connec...

Страница 19: ...s Supply Hose Regulator Filter Assembly Bracket Inlet Port Hose Clamp Filter Hose Figure 3 2a Optional Single Stage Air Filter Installation units with type A Regulator Filter A 03000 Regulator Filter...

Страница 20: ...nit 4 Secure the Strain Relief with the retaining nut re moved earlier 5 Connect the torch Negative Plasma Lead to the bulkhead connection inside the Power Supply Adapter Plug Pilot Lead Torch Lead As...

Страница 21: ...4 The plasma power supply work cable see NOTE is connected to the cutting table at the single point Star ground NOTE Do Not connect the work cable directly to the ground rod 5 Make sure work cable an...

Страница 22: ...20 30 ft 6 1 9 1 m does not generally increase the effective ness of the ground rod A larger diameter rod which has more surface area may help Sometimes keeping the soil around the ground rod moist b...

Страница 23: ...put Hole in the front panel to feed the torch leads through to the internal bulkhead connections 3 Work Cable and Clamp 20 ft 6 1 m work cable with clamp factory installed 4 Roll Handle Torch Leads Wr...

Страница 24: ...or Filter A 03042 1 2 3 Figure4 3b RearPanel unitswithtypeBRegulator Filter 2 PrimaryInputPowerCable StrainRelief Factoryinstalledprimaryinputpowercablestrainrelieffor theprimarypowercable capableofha...

Страница 25: ...ource disconnect switch a AC power is available at the Power Supply 2 Place RUN SET switch to RUN mode 3 Place the ON OFF power switch on the front panel of the Power Supply to ON position a AC Power...

Страница 26: ...r switch on the front panel of the unit to OFF a AC Power indicator turns OFF Fan turns OFF 14 Place the main power disconnect to open a Main AC power is removed from the system NOTE For information o...

Страница 27: ...so be wiped clean If necessary solvents for cleaning electrical apparatus may be used Perform routine maintenance according to the schedule in Appendix 3 The actual frequency of maintenance may need t...

Страница 28: ...be removed from its hous ing dried and reused Allow 24 hours for Element to dry 1 Remove power from power supply 2 Shut off air supply and bleed down system before disassembling Filter to change Filte...

Страница 29: ...replacement proce dures refer to Firepower FP 55 Power Supply Service Manual 0 2847 B How to Use This Guide ThefollowinginformationisaguidetohelptheCustomer Operator determine the most likely causes f...

Страница 30: ...ng of CURRENT control a Check and adjust to proper setting 2 Faulty components in unit a Return for repair or have qualified technician repair per Service Manual F Limited output with no control 1 Poo...

Страница 31: ...ction describes procedures for basic parts replace ment For more detailed parts replacement procedures refer to the Firepower 55 Power Supply Service Manual A Cover Removal 1 Remove the upper screws w...

Страница 32: ...above 2 Locate the internal fuse on the left side of the center chassis 3 Replace the fuse Refer to Section 6 for replacement fuse catalog number 4 Reinstall the cover per paragraph A above A 02957 F...

Страница 33: ...Parts listed without item numbers are not shown but may be ordered by the catalog number shown B Returns If a product must be returned for service contact your distributor Materials returned without p...

Страница 34: ...ilter Assembly Element Replacement 9 8534 for Type A Regulator Filter 1 Regulator Filter Assembly Element Replacement 9 4414 for Type B Regulator Filter 6 05 Optional Equipment Qty Description Catalog...

Страница 35: ...or national codes Cable conductor temperature used is 167 F 75 C An energy limiting fuse UL Class RK 1 examples BUSS LPS LPN RK or Gould Shawmut AZK A6K should be used to minimize damage to Plasma Cu...

Страница 36: ...h is within transfer distance 1 4 in 6 4mm of workpiece main arc will transfer After post flow Gas solenoid closes gas flow stops GAS indicator off ACTION Close external disconnect switch RESULT Power...

Страница 37: ...supply and pressure flow 4 Purge plasma gas line to remove any moisture build up 5 Inspect input power cable for damage or exposed wires replace if necessary Weekly or Every 30 Cutting Hours 1 Check f...

Страница 38: ...APPENDIX A 4 Manual 0 2846 APPENDIX 4 SYSTEM SCHEMATIC A 03269...

Страница 39: ...Manual 0 2846 A 5 APPENDIX A 03269...

Страница 40: ......

Отзывы: