  36E - ZC Builder Booklet

Page 2

Part # 17601184

© 2001, Travis Industries, Inc.

Printed 9/24/04

Di mension s

A

A

AA

A

AA

AA

A

A

A

AA

A

AA

A

A

A

A

A

A

AA

AA

AA

AA

A

A

A

A

A

A

AA

A

AA

AA

A

A

A

A

A

6-1/2"

41"

26"*

42"*

28"

24"

* Includes the 
1/2" stand-offs

36"

The set-up face shipped on the 
fireplace is 36-1/8" wide and 
28-1/16" tall (dimensions 
shown are for the finished face)

Cooling vents 
have an external 
diameter of 6"

Weight: 590 Lbs.

4"

11"

1/2" 
Stand-offs

1"

26-1/2"*

4"

4"

20-1/2"

See "Chimney 
Requirements"

6" Blower hook-ups are on both sides and on the bottom 
(centered 7-5/8" from the rear edge).  Remove the cover 
plate to access the blower hook-up.

Optional Electrical 
Conduit Exit Location

Electrical 
Conduit 
Location

7-5/8"

3-1/4"

1-1/2" Wide Nail 
Down Flange

Packing List

Shipped with the Fireplace:

Installation Manual

Grate

Baffle

Blower Assembly

Ember Strip

Log Retainer (includes allen wrench & instructions)

Flex Duct w/ start collar – 3' Length, 6" Dia (For
Blower)

Two 10' Flex Ducts, 6" Diameter (For Cooling
Vents)

Two Vent Hoods (For Cooling Vents)

Two Vent Hood Storm Collars (For Cooling Vents)

Shipped with the Faceplate:

Faceplate (two switch plate screws are

attached)

Switch Plate (includes blower rheostat)

10 Faceplate Screws

Shipped with the Door(s):

Owner's Manual

Installation Hardware Pack

Pair of Gloves

Efficiency and Registration Cards

Touch-up Paint

Содержание 36E - ZC

Страница 1: ...Flush Floor Hearth Internal or External Chase 8 leads for the power source and the blower 120 Volts A C Set up face is included to ease facing installation 3 blower duct locations for a wide selection...

Страница 2: ...ear edge Remove the cover plate to access the blower hook up Optional Electrical Conduit Exit Location Electrical Conduit Location 7 5 8 3 1 4 1 1 2 Wide Nail Down Flange Packing List Shipped with the...

Страница 3: ...1 Do not build into this area Do not slope the walls inward Framing Dimensions at 45 AAA AAA AAA AAA AAA AAA A A A A A A A A A A AAAAAAAAA 25 1 2 66 1 2 43 26 Fireplace includes 1 2 standoffs 22 1 4 2...

Страница 4: ...d the faceplate NOTE the faceplate protrudes 1 from the front of the fireplace has a 1 8 overlap on the sides and 1 4 overlap on top To achieve a facing that is flush with the drywall to the side of t...

Страница 5: ...ted above this point 15 Raised hearth 3 4 Plywood AAAAAAAAA AAAAAAAAA A A A Fireplace 2 x 8 Framing Faceplate Ember Strip 15 Raised hearth Elevated hearths must be constructed of non combustible mater...

Страница 6: ...25 Included with the fireplace are two 12 lengths of vent use a connector and seal if adding more length The duct terminations must be located so they can not be blocked e g snow drifts Included with...

Страница 7: ...e placed in a ventilated crawl space if approved by the local building department AAAAAAAAAA NOTE The blower may be placed with the grill facing down Do not place the blower on its side The maximum le...

Страница 8: ...s may be used to offset the chimney to align the chimney or gain clearance to combustibles A maximum four 30 elbows may be used Each elbow must be used in conjunction with a return elbow so the chimne...

Страница 9: ...e the chimney penetrates the ceiling use a firestop the chimney must maintain the clearances listed below 5 to the rear of the chimney 4 1 2 to the front of the chimney 2 to the side of the chimney Mi...

Страница 10: ...roof and 2 above any portion within 10 measured horizontally This applies to flat and sloped roofs The chimney must have a chimney cap When using a chase to enclose a chimney the chimney termination...

Отзывы: