Viking RU  Wet 

2.   INSTALLATION RESPONSIBILITIES 

 

WARNING:

 THE APPLIANCE AND FLUE SYSTEM SHALL BE INSTALLED 

IN ACCORDANCE WITH AS/NZ 2918 AND THE APPROPRIATE 
REQUIREMENTS OF THE RELEVANT BUILDING CODE OR CODES. 
 
ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN 
APPROVED IN WRITING BY THE TESTING AUTHORITY IS 
CONSIDERED 
TO BE IN BREACH OF THE APPROVAL GRANTED FOR COMPLIANCE 
WITH AS/NZS 4013. 

 

CAUTION:

  MIXING OF APPLIANCE OR FLUE-SYSTEM COMPONENTS FROM 

DIFFERENT SOURCES OR MODIFYING THE DIMENSIONAL SPECIFICATION 
OF COMPONENTS MAY RESULT IN HAZARDOUS CONDITIONS.  WHERE 
SUCH ACTION IS CONSIDERED, THE MANUFACTURER SHOULD BE 
CONSULTED IN THE FIRST INSTANCE. 
 
Strict adherence to these instructions will meet these standards. 
Any variation from these installation instructions or any doubt about them must be 
checked against the requirements of the Standards. 
 

Please leave this manual with the owner when installation is complete

 
 
 

3.   FLOOR PROTECTOR REQUIREMENTS 

 
The heater should always be installed on top of its base due to high temperatures 
sustained over long periods.  The base must be anchored to both the floor protector and 
the floor for seismic restraint.  Anchor points are provided in the base.  
 
If the heater is installed on or within 500mm of a heat sensitive floor, 

then an ash 

floor

 

protector using a minimum of 6mm thick tiles will be required

.

  This 

floor protector shall extend under the appliance and not less than 300mm beyond the 
front of the fuel loading or ash removal openings.  The width of the floor protector 
shall be not less than the width of the appliance, and shall extend not less than 200mm 
from each side of the fuel loading or ash removal openings unless it forms an abutment 
with a wall or heat shield at a lesser distance. 
 
Where the floor protector consists of a number of components, it shall include a 
continuous layer of heat-resistant material extending under the appliance to the 
perimeter of the floor protector.  All joints shall be fixed to prevent accidental 
separation, and shall be sealed to prevent any spilt ash or embers contacting any heat 
sensitive material. 
 
 
 
 

Содержание Viking RU WET

Страница 1: ...DBURNER This fire is for installing on a property of 2 hectares or more All installations must be in accordance with these instructions Consult with the building authority having jurisdiction to determine the need for a permit prior to commencing the installation Failure to follow these instructions may also void your fire insurance and warranty ...

Страница 2: ...Clearances 6 5 Assembly Instructions 7 6 Wetback 8 7 Flue Installation 9 Minimum Height of Flue System Exit Please complete and return your warranty registration card which is enclosed Edited 22 3 13 Please complete for your future reference Model ___________________________________ Serial No _________________________________ Date of Purchase ___________________________ Purchased from ____________...

Страница 3: ...R AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHEN IT IS OPERATING Use caution when reloading with fuel Do NOT attempt to load fuel into the heater when the fire inside the stove is at or near its peak Do NOT burn large quantities of paper or combustible material that would create an extremely hot quick fire Do NOT burn highly coloured paper or brochures junk mail USE ONLY DRY WOOD AVOID BURNING WE...

Страница 4: ...UIREMENTS The heater should always be installed on top of its base due to high temperatures sustained over long periods The base must be anchored to both the floor protector and the floor for seismic restraint Anchor points are provided in the base If the heater is installed on or within 500mm of a heat sensitive floor then an ash floor protector using a minimum of 6mm thick tiles will be required...

Страница 5: ... 340 mm Width 320 mm Depth 500 mm Flue Size 150mm Heating Area approx 200sqm CLEARANCES A B C D E F G H J K L M N O WITH FLUE SHIELD 100 320 300 120 50 260 590 350 780 1040 1280 1060 780 410 Clearances are shown with an ash floor protector using 6mm ceramic tiles ...

Страница 6: ...ifting lugs are positioned onto the sides of the casting taking care not to catch fingers under the plates 6 Assemble and install the flue as per instructions page 8 9 7 A flue shield must be fitted the minimum requirement is for a single skin semi circular stainless steel flue shield with a reflective inner surface 1200mm high This should be installed so that the bottom edge of the flue shield is...

Страница 7: ...with the shortest and straightest possible pipe run 2 The heater should be within 6 metres of the hot water cylinder the closer the better 3 The flow pipe from the heater to the cylinder must rise the cylinder should be at least 300 mm above the water booster outlet 4 Use only 25mm supply and return pipes 5 Where possible the pipes should be insulated WARNING Care must be taken to protect the wetb...

Страница 8: ...ng screws 8 Place ceiling plate with folded edges upwards over heater spigot 9 Position the flue pipe into the heater spigot The flue pipe can either lowered from the top as a single unit or fed up from the room a length at a time ensuring that all joints are fixed properly 10 Slide the inner casing into place between the outer casing and the flue pipe 11 The flue pipe must extend 200mm above the ...

Страница 9: ...Viking RU Wet 9 ...

Страница 10: ...Hewitsons Limited Manufacturers of Lady Kitchener Bronte Coaster Contessa Dante Encore Zealandia Royale Athena Forte Plaza Deco Aqualux 98 Niven Street PO Box 3231 Onekawa Napier Phone 06 8438260 Fax 06 8430505 Email hothouse firenzo co nz ...

Страница 11: ...Viking RU Wet 11 Web www firenzo co nz ...

Отзывы: