Firenzo Viking AG Скачать руководство пользователя страница 6

Viking AG Wet 

5.  ASSEMBLY INSTRUCTIONS 

 

1.   Remove all outer packaging and timber. 
2.   Remove slotted steel top plates from rear of heater and cast iron top 
plates from inside the heater and carefully set aside, taking care not to 
scratch or damage the paint finishes. 
3.   Position unit onto floor protector ensuring it complies with the 
clearances as shown in section 4 on page 5. 
DO NOT ATTEMPT TO LIFT THE HEATER BY THE GRANITE 
ASHLIP. 
4.   Plumb in the wetback in accordance with accepted plumbing practises 
refer to section 6 page 7.  Ensure the wetback is not pushed down or 
comes into contact with the baffle bricks or flue gas deflectors.  This will 
cause premature wear to the wetback and will not be covered by the 
manufacturer’s warranty. 
5.   Make sure the flat and triangular baffle bricks and the stainless steel 
flue gas deflectors are correctly sited as per diagram on page 10. 
6.   Install the rear cast iron plate and then the front cast iron plate onto the 
rope seals around the top of the firebox and ensure they are bedded down 
well. Lifting lugs are positioned onto the sides of the casting, taking care 
not to catch fingers under the plates. 
7.   Assemble and install the flue as per instructions (page 8 & 9). 
8.  A flue shield must be fitted; the minimum requirement is for a single 
skin, semi-circular, stainless steel flue shield with a reflective inner 
surface 1200mm high.  This should be installed so that the bottom edge of 
the flue shield is 20mm from the top surface of the heater and spaced off 
the flue pipe by approximately 35mm. 
9.   Secure both fire and floor protector to floor by using appropriate 
fastenings through the holes provided in the rear of the base plate.  This is 
a New Zealand Standard 2918 requirement due to NZ being earthquake 
prone. 
10.  Carefully position the main slotted steel painted top panel onto the 
heater, there are locating lugs on the underside that fit into the indents on 
the cast iron tops that ensure it is correctly positioned.  Slide in the rear 
infill top plate behind the flue and the curved top plate locates into the lugs 
onto the back edge. 
11.  Fit door knob with spacer  
as per drawing shown herewith. - 

 
 
 
 
 
 

Содержание Viking AG

Страница 1: ...WET WET AG Clean Air FREESTANDING WOODBURNER All installations must be in accordance with these instructions Consult with the building authority having jurisdiction to determine the need for a permit...

Страница 2: ...llation is complete INDEX Page No Item No Topic 3 1 Warnings 4 2 Installation Responsibilities 4 3 Floor Protector Requirements 5 4 Installation Clearances 6 5 Assembly Instructions 7 6 Wetback 8 7 Fl...

Страница 3: ...AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHEN IT IS OPERATING Use caution when reloading with fuel Do NOT attempt to load fuel into the heater when the fire inside the stove is at or near its peak...

Страница 4: ...IREMENTS The heater should always be installed on top of its base due to high temperatures sustained over long periods The base must be anchored to both the floor protector and the floor for seismic r...

Страница 5: ...340 mm Width 320 mm Depth 500 mm Flue Size 150mm Heating Area approx 200sqm CLEARANCES A B C D E F G H J K L M N O WITH FLUE SHIELD 100 320 300 120 50 260 590 350 780 1040 1280 1060 780 410 Clearances...

Страница 6: ...around the top of the firebox and ensure they are bedded down well Lifting lugs are positioned onto the sides of the casting taking care not to catch fingers under the plates 7 Assemble and install th...

Страница 7: ...ith the shortest and straightest possible pipe run 2 The heater should be within 6 metres of the hot water cylinder the closer the better 3 The flow pipe from the heater to the cylinder must rise the...

Страница 8: ...g screws 8 Place ceiling plate with folded edges upwards over heater spigot 9 Position the flue pipe into the heater spigot The flue pipe can either lowered from the top as a single unit or fed up fro...

Страница 9: ...Viking AG Wet 9...

Страница 10: ...Viking AG Wet 10 IMPORTANT UPON INSTALLATION CHECK THAT THE TRIANGULAR BRICK ON TOP OF THE BAFFLES IS PLACED AS SHOWN...

Страница 11: ...itsons Limited Manufacturers of Lady Kitchener Bronte Coaster Contessa Dante Zealandia Royale Athena Forte Aqualux 68 Austin Street PO Box 3231 Onekawa Napier Phone 06 8438260 Fax 06 8430505 Email hot...

Отзывы: