5
Part 1 - INSTALLATION INSTRUCTIONS
3.1 - Installation of the fitted group
1 - Make a
rectangular
opening in the
base of the
overhead
cupboard or
hood, leaving a
minimum of
13 mm
from the
outer edges according to the
dimensions indicated in the
table.
2 - Drill a hole into the upper side
of the cabinet in accordance
with the dimensions of the
duct used for both the
evacuation and recirculation
mode.
3 - Dismantle the ducting support
(version with grill or version
with filters), pulling the two
pommels
A
(fig. 1)
simultaneously:
a) Fixing frame with screws:
Fix the fitted group to the hood
or cupboard, using the self-
threading screws
(No. 10)
provided with the
accessories
(fig. 2)
.
b) Rapid fixing with side
supports:
The device
B
is set up
to deal with a panel
thickness of from
15
mm
to
30 mm
. Insert
the group into the
opening until the two
devices
B
connect. Lock
the adjustment screw
C
until the fitted group adheres
tightly to the surface
(fig. 2)
.
1
2
Содержание FCA 550
Страница 1: ...INSTRUCTION BOOKLET COOKER HOOD FCA 550 GB...
Страница 2: ...2...