WARNING 

 

Do not store or use gasoline or other flammable vapors or liquids in vicinity of this or any appliance. 

 

An LP gas cylinder shall not be stored in the vicinity of this or any other appliance. 

 

Never operate with a LP gas cylinder inside. 

 

 

IMPORTANT 

 

Installation must adhere with local codes and with the National Fuel Gas Code, 

 

ANSI Z223.1/NFPA 54 or the Natural Gas and Propane Installation Code, CSA B149.1

 

 

 

CARBON MONOXIDE HAZARD 

 

This burner will produce carbon monoxide which has no odor. 

 

As with any vented heating appliance, harmful carbon monoxide is produced during 

the combustion process that should not be allowed to accumulate in a confined space. 

 

A fully functional wood-burning fireplace with the damper in the fully open position is 

required. 

 

It is required that carbon monoxide detectors be positioned and properly maintained 

in the vicinity of the fireplace area. 

 

 

GENERAL SAFETY & INSTALLATION WARNINGS 

 

 

Safe operation of this burner depends upon its proper installation.  

 

A qualified professional installer and service technician must perform adjustments and service of the burner.  

 

Proper location and proper use is essential to insure safe and continued trouble-free operation.  

 

Any non-approved alterations made to the fireplace burner will void the product’s warranty. 

NOTE:

 The manufacturer cannot be held responsible for damage or injury caused by improper use or installation of this 

burner.

  

 

IMPORTANT:

 Consult the AHJ (Authority Having Jurisdiction) or local contractor of any uncertainty in regards to 

installation. 

 

IMPORTANT

: Have an ABC Fire Extinguisher accessible at all times.  

 

 

CALIFORNIA PROPOSITION 65 WARNING  

WARNING: 

This product can expose you to chemicals including Chromium (hexavalent 

compounds), which are known to the State of California to cause cancer and birth defects 

or other reproductive harm. For more information go to: www.P65Warnings.ca.gov 

 

 

MASSACHUSETTS RESIDENTS: 

 

Installation must be performed by a licensed plumber or gas fitter.  

 

The chimney flue damper, when used with gas logs, will be welded open or completely removed. 

 

A carbon monoxide detector shall be installed in the room where the appliance is installed.  

 

A naturally vented gas log may not be installed in a bedroom or bathroom in the commonwealth of mass. 

 

Flexline installation must not exceed 36” 

 

The appliance on/off valve must be a T-handle gas cock.  

Содержание FN-SGLBV24-NG

Страница 1: ... any open flame Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Exit the building and immediately call your gas supplier Follow your gas supplier s instructions If you cannot reach your gas supplier call the fire department WARNING Read the installation operation and maintenance instructions thoroughly before installing operating or servic...

Страница 2: ...d service of the burner Proper location and proper use is essential to insure safe and continued trouble free operation Any non approved alterations made to the fireplace burner will void the product s warranty NOTE The manufacturer cannot be held responsible for damage or injury caused by improper use or installation of this burner IMPORTANT Consult the AHJ Authority Having Jurisdiction or local ...

Страница 3: ...ll be HOT DO NOT TOUCH SEVERE BURNS MAY RESULT CLOTHING COULD IGNITE CAREFULLY SUPERVISE children in areas where the fireplace is located during and after operation Alert children and adults to hazards of high temperatures Clothing or other flammable materials should not be near the fireplace ADDITIONAL WARNINGS Please read all instructions before installing or operating your burner to prevent inj...

Страница 4: ...never be allowed to touch sit or stand on any part of the burner Wear proper clothing when operating this burner Loose fitting or hanging garments should never be worn while using the burner Do not leave the burner unattended while in use Do not leave the burner in use while sleeping If glass doors are present always operate with doors in the fully opened position When the gas valve is in the OFF ...

Страница 5: ... burner must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 5 kPa The burner and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system The minimum inlet natural gas suppl...

Страница 6: ... cleaned cleared of any soot ashes creosote loose paint and or debris Consult a fireplace inspecting professional as well as a chimney cleaning professional Free opening area of chimney damper for venting combustion products factory built fireplaces Chimney Height Ft Appliance Input Rate kBTU hr Minimum Opening Sq In 20 110 50 25 110 45 30 110 39 35 110 36 40 110 33 Height is from hearth to top of...

Страница 7: ...ription Part Tool List Firenado Burner 1 Crescent Wrench x2 Grate 2 Long Flathead Screwdriver 12 Non Whistling Flex Connector 3 Leak Checker Soapy Water 3 8 Inch Elbow Fitting 4 Gas Approved Pipe Sealing Compound 1 2 Inch Elbow Fitting 5 or Gas Approved Teflon Tape NG Orifice Fitting 6 Heat Resistant Gloves Gas Cap 7 Pencil Damper Clamp 8 Pipe Wrench Sand Granule Pack 9 Long Fireplace Matches Glow...

Страница 8: ...as connection inside the wall Remove the log lighter gas cap and or fittings leaving just the main gas feed line Assemble the gas connections onto the burner The gas log burner is designed to accept the gas supply from either the right hand or the left hand side of the burner to adjust to the side of the fireplace in which the gas comes in Install the straight gas orifice fitting on the gas supply...

Страница 9: ... the connection points Correct any leaks before proceeding Fill the burner with the included sand granules Slope the sand with the shape of the burner tapering it from the front to the back Avoid spilling the sand outside of the pan as much as possible Cover the burners completely Do not pat down Note you may have extra sand when done See Figure A Install the glowing ember material to the top of t...

Страница 10: ...ticed in the room soot at the top of the fireplace opening soot directly above the fireplace soot on the underside of the fireplace mantel and or soot anywhere in the room Discontinue use of the gas log set immediately until the issue has been properly corrected by a certified chimney professional OPERATING YOUR BURNER Before Lighting Smell at and around the burner and fireplace area and next to t...

Страница 11: ...anywhere in the room Discontinue use of the gas log set immediately until the issue has been properly corrected by a certified chimney professional Sooting on logs Some sooting of the logs can be expected but excessive sooting can be caused by the following items high gas pressure logs may be placed tightly together not allowing a path for fire and draft to move through or fireplace venting system...

Страница 12: ...with warranty parts All warranty claims are subject to manufacturer review Please make sure to have your sales receipt information All replacement parts can be purchased through your local stocking dealer This warranty is intended for the original purchaser and is nontransferable WHAT IS NOT COVERED Cost of removal and or reinstallation Shipping and or transportation cost Service calls to determin...

Отзывы: