WARNING
•
Do not store or use gasoline or other flammable vapors or liquids in vicinity of this or any appliance.
•
An LP gas cylinder shall not be stored in the vicinity of this or any other appliance.
•
Never operate with a LP gas cylinder inside.
IMPORTANT
•
Installation must adhere with local codes and with the National Fuel Gas Code,
ANSI Z223.1/NFPA 54 or the Natural Gas and Propane Installation Code, CSA B149.1
CARBON MONOXIDE HAZARD
•
This burner will produce carbon monoxide which has no odor.
•
As with any vented heating appliance, harmful carbon monoxide is produced during
the combustion process that should not be allowed to accumulate in a confined space.
•
A fully functional wood-burning fireplace with the damper in the fully open position is
required.
•
It is required that carbon monoxide detectors be positioned and properly maintained
in the vicinity of the fireplace area.
GENERAL SAFETY & INSTALLATION WARNINGS
•
Safe operation of this burner depends upon its proper installation.
•
A qualified professional installer and service technician must perform adjustments and service of the burner.
•
Proper location and proper use is essential to insure safe and continued trouble-free operation.
•
Any non-approved alterations made to the fireplace burner will void the product’s warranty.
NOTE:
The manufacturer cannot be held responsible for damage or injury caused by improper use or installation of this
burner.
IMPORTANT:
Consult the AHJ (Authority Having Jurisdiction) or local contractor of any uncertainty in regards to
installation.
IMPORTANT
: Have an ABC Fire Extinguisher accessible at all times.
CALIFORNIA PROPOSITION 65 WARNING
WARNING:
This product can expose you to chemicals including Chromium (hexavalent
compounds), which are known to the State of California to cause cancer and birth defects
or other reproductive harm. For more information go to: www.P65Warnings.ca.gov
MASSACHUSETTS RESIDENTS:
•
Installation must be performed by a licensed plumber or gas fitter.
•
The chimney flue damper, when used with gas logs, will be welded open or completely removed.
•
A carbon monoxide detector shall be installed in the room where the appliance is installed.
•
A naturally vented gas log may not be installed in a bedroom or bathroom in the commonwealth of mass.
•
Flexline installation must not exceed 36”
•
The appliance on/off valve must be a T-handle gas cock.