12
Purevision LPV Freestanding
Issue 01 02/21
6.0
Technical Data & Declaration of Performance (DoP)
Manufacturer:
Fireline UK Ltd, a Division of Charlton & Jenrick Ltd.
Range Designation:
Purevision LPV Linear freestanding stoves.
Models:
Purevision LPV 5, 5kW and LPV 8, 8kW with nominal outputs of 5kW and 8kW.
Intended Use:
Domestic heating appliances
Independently Performance & Safety tested by:
Kiwa Gastec, NB No: 0558/Kiwa Cermet Italia, NB No: 0476
Constancy of Performance System:
ISO9001
Signed:
Peter Mintoft
Director
February 2021
NOTE:
Refuelling intervals for testing are chosen according to the standards concerned for performance testing and are comparative
only. They
do not
relate directly to re-fuelling intervals that can be achieved on an installed product. Re-fuelling intervals of 1-1.5h for
wood and 3-4+ hours for briquetted smokeless fuels would be more usual. Under normal conditions on a low air control setting stoves
should stay in overnight on suitable briquetted smokeless fuel.
Model
Purevision
LPV 5 Linear
5kW
Purevision
LPV 8 Linear
8kW
Notes
Appliance weight (packed/unpacked) (Kg):
96/86
132/119
Approximate Output Range: (kW)
3.8-7.1
5.0-9.9
Harmonised EN European Standard (hEN):
EN13240:
2001 Amd 2:
2004
EN13240:
2001 Amd 2:
2004
Additional Characteristics Test Standard:
DIN +
DIN +
Additional Particulate Emission Test Standard:
PD6434
PD6434
Performance Characteristics using Wood Fuel
Test Report Issue Date:
02/2021
02/2021
Total Efficiency: (%)
79.6
76.5
Declared nominal output: (kW)
5.0
8.0
Tested nominal Output: (kW)
5.0
7.9
Tested wood re-fuelling interval: (h)
0.82
0.75
Flue gas mass flow: (g/s)
4.0
6.4
Mean CO emission (@13% O
2
) : (%)
(Nmg/m
3
)
0.1
(1250)
0.12
(1500)
Mean C
n
H
m
emission (@13% O
2
): (Nmg/m
3
)
58
63
Mean NOx emission (@13% O
2
): (Nmg/m
3
)
93
90
DIN+ particulates (@13% O
2
): (Nmg/m
3
)
20
30
PD6434 Particulate Emissions High output: (gh
-1
)
2.7
2.0
PD6434 Particulate Emissions Low output: (gh
-1
)
1.8
1.5
Optical Density Time > 0.2 High (Mins)
0.5
0.0
Optical Density Time > 0.2 Low (Mins)
0.1
0.2
*Mean Flue Temperature: (Deg C)
283
330
clearSkies Level
5
4
EEI Energy Rating Category
A
A
Approximate Max Log Length: (mm)
320
550
Safety Distances From Combustibles
Side Wall: (mm)
650
750
Rear Wall: (mm)
300/80
450/200