![Firegear SAN1-30LHAWS-N Series Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/firegear/san1-30lhaws-n-series/san1-30lhaws-n-series_installation-and-operating-instructions-manual_2291653004.webp)
REV. A Page 4
Sanctuary 1 Fire Feature
SANCTUARY SPECIFICATIONS
Table 1
Sanctuary Specifications
Fig 2
. Clearance to Combustibles
(Not to be used in an enclosed space)
SAN 1 Model &
Burner Model
Natural Gas = N/Propane Gas = P
NG
Orifice
LP
Orifice
Btu's
SAN1-30LHMT-N/P-*
LOF3313FH276MT-N/P
#29
#41
75,000
(21.98KW)
SAN1-30LHTMSI-N/P-*
LOF3313FH276TMSI-N/P
#29
#41
75,000
(21.98KW)
SAN1-30LHTPSI-N/P-*
LOF3313FH276TPSI-N/P
#29
#41
75,000
(21.98KW)
SAN1-30LHAWS-N/P-*
LOF3313FH276AWS-N/P
LOF-30LHAWS-N/P-SAN**
#29
#41
75,000
(21.98KW)
Table 2
Model Specifications
** Denotes a drop-in-pan model. All other models listed are
flat pans with H burners.
Model:
Natural Gas =N
Propane Gas = P
Overall
Size
Inside
Width
Inside
Depth
Height
Combustible
Side Wall
Clearance
Combustible
Ceiling
Clearance
SAN1-30LHMT-N/P-*
56” x 38” 33½” x 13½” 2½”
16”
16”
69”
SAN1-30LHTMSI-N/P-*
56” x 38” 33½” x 13½” 2½”
16”
16”
69”
SAN1-30LHTPSI-N/P-*
56” x 38” 33½” x 13½” 2½”
16”
16”
69”
SAN1-30LHAWS-N/P-*
56” x 38” 33½” x 13½” 2½”
16”
16”
69”
Disclaimer:
Btu listings are based on 7.0”WC for Natural
Gas and 11.0”WC for Liquid Propane (LP) to the gas valve.
Flex line size and proper gas pipe sizing will also affect
Btu’s. As a result your Btu’s may vary slightly from Table 2
specifications.
Pressure
NG
LP
Min. Inlet
5.0” WC
10.5” WC
Max. Inlet
10.5” WC 13.0” WC
Normal Inlet 7.0” WC
11.0” WC
Table 3
Gas Pressures
Fig. 1
Sanctuary Dimensions
69”
16”
16”
Combustible Ceiling
Combusible
Side W
all
2½”
33”
33½”
16”
56”
52¼”
12¼”
11¼”
33”
56”
38”
10½”13½”
3”
TOP VIEW
SIDE VIEW
33½”
38”
34¼”
16”
135/8”
6”
1½”
3”
END VIEW
2½”
13½”