REV. A Page 9
Drop in Pan - AWS Fire Pits
PREPARING A NON-COMBUSTIBLE STRUCTURE FOR A SINGLE INSTALL
POWER SUPPLY LOCATION
The GOE-30VDC power supply is to be installed inside the enclosure due to the wire length limitations. The power cord is
3-feet long the 30VDC leads to the valve are 3-feet long. See Fig. 5.
Fig. 6
Example of a single fire feature install.
Note
: Must be 10-feet or more from a pool/spa.
Wall
Switch
Timer
FG-1420-A OD
Remote
Emergency
Stop
(Optional)
FG-PS-30V320
Low Voltage
Power Supply
Key Valve
Electrical Line
Gas Line
ON
OFF
or
or
Main Burner
Flat Pan
Pilot Burner
(Min. 12-gauge)
Flex Frame (shown in detail)
enables the ability to
remove the pan/disc
to service valve system
Flex
Frame
Min.-Max. Distance
Pilot Run
6” to 22”
Optional ON/OFF
Controls
Note: Actual power supply must be
10-feet or more from the pool or spa
DETAIL
Pool
Control
Pool Certified Applications
(Fire Feature within 5-feet of pool or spa)
Pool
PREPARING A NON-COMBUSTIBLE STRUCTURE FOR A SINGLE POOL INSTALL
Fig. 7
Example of a single fire feature install within 5-feet of a pool/spa.
Note:
Reguires FG-PS-30V320 power supply (purchased seperately). Do not use the GOE-30VDC.
FG-PS-30V320 power supply can be installed up to a maximum of 500-feet away from fire pit.