background image

REV.  C      Page 7

Drop in Pan - AWS Fire Pits

REFERENCE

GAS PIPE SIZING

Length of Pipe in Feet

1/2”

3/4”

1”

1 - 1/4”

1 - 1/2”

2”

2 - 2 1/2”

3”

4”

10

275

567

1071

2205

3307

6221

10140

17990

35710

20

189

393

732

1496

2299

4331

7046

12510

25520

30

152

315

590

1212

1858

3465

5695

10110

20620

40

129

267

504

1039

1559

2992

4778

8481

17300

50

114

237

448

913

1417

2646

4343

7708

15730

60

103

217

409

834

1275

2394

3908

6936

14150

70

89

185

346

724

1086

2047

3329

5908

12050

80

78

162

307

630

976

1811

2991

5309

10830

90

69

146

275

567

866

1606

2654

4711

9613

100

63

132

252

511

787

1496

2412

4281

8736

125

54

112

209

439

665

1282

2083

3618

7382

150

48

100

185

390

590

1138

1808

3210

6549

175

43

90

168

353

534

1030

1637

2905

5927

200

40

83

155

325

491

947

1505

2671

5450

300

37

77

144

303

458

887

1404

2492

5084

NATURAL GAS : PIPE SIZING CHART

Natural Gas (NG) flow is given in 
thousands of BTU/hr. = 1 cubic 
foot of NG gas - 1000 BTU

Nominal pressure at the burner 
for Natural Gas is 3.5” of water 
column. (Typical machine supply 
5”-7”)

Pipe length must include 
additional length for all fittings. 
Add approximately 5 feet of pipe 
per fitting.

Natural Gas Example: A machine 
with a burner that requires 
440,000 BTU would need a 1 -1/4” 
pipe for a 20” long run. 

LIQUID PROPANE : PIPE SIZING CHART

NOTE: The sizing charts above list the specific pipe sizes required for the amount of BTU’s for a new gas line installations. If you 
are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have proper 
pressure. 

This chart is for reference only, we recommend you consult with a Licensed Plumber/Gas Fitter or NFPA54 (National Fuel 

Gas Code - current edition) for more details.

Length of Pipe in Feet

1/2”

3/4”

1”

1 - 1/4”

1 - 1/2”

2”

2 - 2 1/2”

3”

4”

10

108

230

387

793

1237

2259

3640

6434

-

20

75

160

280

569

877

1610

2613

5236

9521

30

61

129

224

471

719

1335

2165

4107

7859

40

52

110

196

401

635

1143

1867

3258

6795

50

46

98

177

364

560

1041

1680

2936

6142

60

42

89

159

336

513

957

1559

2684

5647

70

38

82

149

317

476

896

1447

2492

5250

80

36

76

140

239

443

840

1353

2315

4900

90

33

71

133

275

420

793

1288

2203

4667

100

32

68

126

266

411

775

1246

2128

4518

125

28

60

117

243

369

700

1143

1904

4065

150

25

54

105

215

327

625

1008

1689

3645

175

23

50

93

196

303

583

993

1554

3370

200

22

47

84

182

280

541

877

1437

3160

300

17

37

70

145

224

439

686

1139

2539

Liquid Propane (LP) Gas flow is 
given in thousands of BTU/hr.  =
1 cubic foot of LP gas - 2500 BTU.

This chart refers to low pressure LP, 
after regulation, Standard nominal 
pressure at the burner for Liquid 
Propane Gas is 11” of water column.

Pipe length must include additional 
length for all fittings. Add 
approximately 5 feet of pipe per 
fitting.

LP Example: A machine with a 
burner that requires 440,000 BTU 
would need a 1” pipe for a 20’ long 
run. 

GAS PIPE SIZING CHART

Table 4

  Gas pipe sizing.

Содержание LOF-2406TAWS-N

Страница 1: ... 48 x 14 Fire Pit with H Burner LOF 6016HAWS N P 60 x 16 Fire Pit with H Burner LOF 7216HAWS N P 72 x 16 Fire Pit with H Burner LOF 8416HAWS N P 84 x 16 Fire Pit with H Burner LOF 9616HAWS N P 96 x 16 Fire Pit with H Burner MODELS H Burner T Burner DO NOT DISCARD THIS MANUAL HAS IMPORTANT OPERATING AND MAINTENANCE INSTRUCTIONS LEAVE WITH THE HOMEOWNER MODEL SERIAL PN 90136 Models NG LP Description...

Страница 2: ...partment DANGER WARNING Do not store or us gasoline or other flammable vapors and liquids in the vicinity of this or other appliances Any LP cylinder not connected for use shall not be stored in the vicinity of this or other appliances WARNING Do not leave unattended during use Do not use for cooking Follow all gas leak procedures in this manual prior to operation WARNING Improper installation adj...

Страница 3: ...ture differences When this happens the media has the potential to crack or pop outside the fireplace WE HIGHLY RECOMMEND COVERING ALL FIRE FEATURES WHEN NOT IN USE The use of a cover can lessen the impact of thermal spalling however heavy rains high humidity and the presence of moisture may still cause the media to pop ALWAYS USE CAUTION WHEN USING THE FIRE FEATURE Extra caution should be taken wh...

Страница 4: ...16HAWS P 84 x 16 2133 x 406mm 86 x 18 2197 x 469mm 81 x 10 2057x 254mm 85 x 17 2159 x 330mm 8 203mm 8 203mm 120 3048mm 18 457mm LOF 9616HAWS N LOF 9616HAWS P 96 x 16 2438 x 406mm 98 x 18 2501 x 469mm 93 x 10 2362 x 254mm 97 x 17 2463 x 330mm 8 203mm 8 203mm 120 3048mm 18 457mm Fig 1 H style burner pan specifications SPECIFICATIONS Model N Natural P Propane Natural Orifice Btu Ratings Propane Orifi...

Страница 5: ... x 178mm 8 203mm 36 914mm 120 3048mm 18 457mm LOF 9606TAWS N LOF 9606TAWS P 96 x 6 2438 x 152mm 98 x 8 2501 x 215mm 93 2362mm 97 x 7 2463 x 178mm 8 203mm 36 914mm 120 3048mm 18 457mm SPECIFICATIONS Model N Natural P Propane Natural Orifice Btu Ratings Propane Orifice LOF 2406TAWS N LOF 2406TAWS P OAS NG34 50 000 14 65kW OAS LP47 LOF 3006TAWS N LOF 3006TAWS P OAS NG34 50 000 14 65kW OAS LP47 LOF 36...

Страница 6: ...a around the pipe with weather sealant Consult a plumber for proper installation to ensure you are providing adequate gas supply for your application 4 The primary gas shut off not supplied will require a male flared fitting to enable connection of the stainless steel flex gas line not supplied with the fire feature see Fig 5 page 9 5 Do not place an LP tank inside any fire pit enclosure Locate al...

Страница 7: ...ired for the amount of BTU s for a new gas line installations If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have proper pressure This chart is for reference only we recommend you consult with a Licensed Plumber Gas Fitter or NFPA54 National Fuel Gas Code current edition for more details Length of Pipe in Feet 1 2 3 4 1 1 ...

Страница 8: ...ase of the orifice to provide a cleaner flame See Fig 5 ELECTRICAL INFORMATION Wire Gauge Is the wire gauge correct Wiring must be 12AWG or greater solid or stranded for all installations Note It is recommended to fill the wire nuts with either dielectric grease or silicone prior to installing the wire nut This will ensure a waterproof connection Why GFI circuit A GFI is a type of circuit breaker ...

Страница 9: ...l Line Gas Line ON OFF or or Main Burner Flat Pan Pilot Burner Min 12 gauge Flex Frame shown in detail enables the ability to remove the pan disc to service valve system Flex Frame Min Max Distance Pilot Run 6 to 22 Optional ON OFF Controls Note Actual power supply must be 10 feet or more from the pool or spa DETAIL Pool Control Pool Certified Applications Fire Feature within 5 feet of pool or spa...

Страница 10: ...er Use dielectric grease on all wire nut connections and connectors to prevent moisture issues from the outdoor environment Fig 8 Shows carton contents Note H burner was illiustrated for this drawing The AWS system is polarity sensitive There is a red sleeve attached to the positive side of the adapter When wiring the remote control receiver one red wire from the receiver connects to the adapter w...

Страница 11: ...d Red Red Red Black Red Black Red Sleeve FG 1420 AOD Receiver GOE 30VDC Power Supply Heat Shield 120VAC Power GFI Outlet Orifice Fig 10 Shows typical installation of fire pit using AWS system LEARN Weather Proof Box AWS Valve Box GFI Box Adapter Weather Proof Box Red R e d R e d Red Black Black Red Red Black Antenna Red Sleeve Fig 9 Wire diagram of AWS system with 1420 A remote control receiver ...

Страница 12: ... Cover the burner completely with media but do not make the depth greater than 1 inch overtop of the burner port holes Do NOT cover the top of the screen hood with any rock or glass It must be free an any debris to operate properly Media Required Per H Burner Models N Natural P Propane Lava Rock Only Glass Only Lava Stones Only LOF 2412HAWS N P 10lbs 15lbs 10lbs LOF 3012HAWS N P 15lbs 20lbs 15lbs ...

Страница 13: ...evere burns if contacted 2 Do not burn any solid fuels in this appliance READ ALL LIGHTING INSTRUCTIONS BEFORE ATTEMPTING TO LIGHT FIRE PIT CAUTION ENSURE YOU HAVE LEAK TESTED THE FIRE PIT BEFORE OPERATING AND THE TRANSMITTER AND RECEIVER HAVE BEEN LEARNED PROGRAMED TOGETHER FOR WIRELESS OPERATION WARNING Do not stand over fire pit during ignition or operation due to high surface temperatures LIGH...

Страница 14: ...REV C Page 14 Drop in Pan AWS Fire Pits AWS REPLACEMENT PARTS 1 2 6 7 5 Drawings not to scale 4 3 8 14 9 11 10 12 13 15 10a OUT GOE 30DCV Junction Box Weatherproof Cover Lid 7A ...

Страница 15: ... with 27 T burner 1 78033 3 36 x 6 LT Burner Pan Only use with 33 T burner 1 78034 3 48 x 6 LT Burner Pan Only use with 45 T burner 1 78035 3 60 x 6 LT Burner Pan Only use with 57 T burner 1 78036 3 72 x 6 LT Burner Pan Only use with 69 T burner 1 78037 3 84 x 6 LT Burner Pan Only use with 81 T burner 1 78058 3 96 x 6 LT Burner Pan Only use with 93 T burner 1 78061 4 21 T Burner Only used with 24 ...

Страница 16: ...downpours could affect the fire pit operation if not covered if this occurs ensure you allow the fire pit time to dry out before attempting to operate NOTE If a combustible type cover is used over the fire pit when not in use be sure to remove it before operation to prevent a severe safety hazard 5 Carbon soot may build up on the surface of logs if installed during heavy use Sooting may also occur...

Страница 17: ...nverting Natural gas burners to LP gas the main burner orifice must be kept a minimum of 6 inches away from the burner connection nipple to prevent any back pressure at the LP orifice See Fig 12 below for details Note It is acceptable to install a 90 elbow if necessary to run the gas line the opposite direction see Fig 13 or 14 A 90 elbow is not provided with the kit Note Pilot conversion kit FG A...

Страница 18: ...cted 120VAC power directly to the gas valve the controller inside the valve box will be damaged It this happens a burned electrical smell might be present Connector Not Plugged In Correctly Check the 2 Pin connector from pilot to the gas valve Ensure it is plugged into place with the locking latch Pins Not Secure Check the pins inside the 2 pin connector ensure they are not loose If loose push the...

Страница 19: ...ermopile from the pilot assembly and slide it out If it will not slide out because is it too tight then it will need to be replaced Debris Debris can get trapped inside the screen of the gas valve Over time rust and other debris can restrict the gas flow on the Outlet screen of the valve that can partially or sometimes even stop the flow Inspect the screen remove it and clean it then replace it De...

Страница 20: ...t Remove some of the fire glass media from the burner to see if this fixes the problem Gas Leak Natural Gas is lighter than air therefore when released into the atmosphere it rises If you have a Natural Gas fire feature and there is a gas leak the Natural Gas will rise to the top of the feature Once it encounters the flame a flare up will occur Propane is heavier than air so if there is a gas leak...

Страница 21: ...AVER VENT 6 LNTS Shut Off Valves Model 01 387 OD Flare x FIP Model 01 487 OD Flare x FIP Model 01 266 OD Flare x OD Flare Model 01 288 OD Flare x OD Flare LP Conversion Kit Model FG AWS PBO P Converts primary pilot orifice to LP gas Note In addition requires the main burner orifice to be changed to an L P orifice purchased separately from supplier See pages 4 5 for LP orifice Glass Windshields See...

Страница 22: ... WARRANTY REFRACTORY GAS LOG SETS FIVE 5 YEAR WARRANTY READY TO FINISH ANF FIRE PIT ENCLOSURES FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS OUTDOOR FIREPLACE KALEA BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS FIVE 5 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTION...

Страница 23: ...E KALEA BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS TWO 2 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS TWO 2 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS SANCTUARY SERIES GFRC FIRE FEATURES THREE 3 YEAR WARRANTY GFRC STRUCTURE REFER TO THE APPROPRIATE BURNER SYSTEM FOR WARRANTY WARRANTY COVERS MANUFACTURING DEFECT...

Страница 24: ...r the defect on warranty parts to and from the factory will be the responsibility of the owner We will not be responsible for labor charges and or damage incurred in installation repair and replacement Firegear is not responsible for Issues related to gas or electrical installation The Limited Warranty is voided if not assembled installed and operated as intended This Limited Warranty does not cov...

Страница 25: ...r the defect on warranty parts to and from the factory will be the responsibility of the owner We will not be responsible for labor charges and or damage incurred in installation repair and replacement Firegear is not responsible for Issues related to gas or electrical installation The Limited Warranty is voided if not assembled installed and operated as intended This Limited Warranty does not cov...

Страница 26: ...ental or consequential damages so this limitation or exclusion may not apply to you We do not authorize any person or company to assume for it any other obligation or liability in connection with the sale installation use removal return or replacement of its equipment and or such representation are binding Firegear Outdoors 17322 Gothard Street Huntington Beach CA 92647 www firegearoutdoors com Ph...

Страница 27: ...REV C Page 27 Drop in Pan AWS Fire Pits NOTES ...

Страница 28: ..._ 2 Serial Number ___________________________ 3 How long is the gas line run Nat Gas ____ LP Gas ____ 4 What size is gas line _____ 5 Inlet Gas Pressure _____WC Manifold Gas Pressure _____ WC 6 What type of media are you using __________________ 7 Review the troubleshooting section in the installation manual 8 What are the symptoms Please be prepared to explain 9 Be prepared to send photos to us w...

Отзывы: