background image

MODELS:

FPB-19DSI/N (19-inch Round Fire Pit)

FPB-25DSI/N (25-inch Round Fire Pit)

MODELS:

FPB-1414DSI/N  (14-inch Square Fire Pit)

FPB-2020DSI/N  (20-inch Square Fire Pit)

FPB-2626DSI/N  (26-inch Square Fire Pit)

Outdoor Fire Pit

Installation and Operating Instructions

IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS DO 

NOT  ATTEMPT TO INSTALL OR OPERATE THIS APPLIANCE

Warning:

  For Outdoor Use Only

PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE

INSTALLTION PRECAUTION

 

This fire pit requires a minimum 18-square inches of cross ventilation. Failure to     

provide proper ventilation can void the warranty.

Содержание FPB-1414DSI/N

Страница 1: ...tdoor Fire Pit Installation and Operating Instructions IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS DO NOT ATTEMPT TO INSTALL OR OPERATE THIS APPLIANCE Warning For Outdoor Use Only PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE INSTALLTION PRECAUTION This fire pit requires a minimum 18 square inches of cross ventilation Failure to provide proper ventilation can void the warrant...

Страница 2: ...58 6 9 95 8 8 A3 B2392 254 8 C D438E 3F 38 58 897 4 4659 958 G377 H C I 4 F234 56673589 38 58 897 4 4659 4 92 54 5 95 6 J F 8FJ 95 2 C 03 2 1 02 2 03 2 01 902 2 0 7 90 A 21 1 6 2 1 0 9 2 61 6 10 7 A 6 1 2 B 1 1 7 03 K L D M K 1L 0 1 1 2 1 03 1 4 5 6 1 7 28 27 2 03 5292 20 032 1 03 1 66 2 9 61 6 1 2 0 02 A 7B 0 0A 0 1 02 A 1529 1 2 0 9 9 9 2 B 1 1 61 6 10 7 C 7 03 2 0 02 A 6 1 02 7 2 0 9 2 01 902 0...

Страница 3: ...provide a minimum of 1 2 square inches 3 23 cm for each pound of propane LP contained in the tank see example below Every opening must have minmum dimensions to allow entrance of a 1 2 3 2 mm diameter rod Ventilation openings in side walls must not connunicate directly with other enclosures of the fire pit The cyclinder valve must be easily accessible by hand Connections should be easy to leak tes...

Страница 4: ...Pit 4 Cross Ventilation Requirements 4 Installation Into An Approved Enclosure Requirements 5 Installation of Battery Pack 6 Installation of Lava Rock Media 6 Learning the Remote to Module 7 Operation Initial Start Up 8 Replacement Parts 9 Replacement Parts List 10 Fire Pit Maintenance 11 Trouble Shooting 11 Wiring Diagram 12 Accessory Parts 13 Warranty 14 TABLE OF CONTENTS REV 10 10 12 Page 3 ...

Страница 5: ...h Btu s Natural Propane LP Low Btu s Natural Propane LP FPB 19DSI N 80 000 Btu s 50 000 Btu s FPB 25DSI N 110 000 Btu s 50 000 Btu s FPB 1414DSI N 45 000 Btu s 30 000 Btu s FPB 2020DSI N 110 000 Btu s 50 000 Btu s FPB 2626DSI N 110 000 Btu s 50 000 Btu s Table 2 Btu Specifications NG LP Min Inlet 5 0 WC 11 0 WC Max Inlet 10 5 WC 13 0 WC Table 3 Gas Pressures MODEL FPB 19DSI N FPB 25DSI N FPB 1414D...

Страница 6: ...he Fire Pit to the male flared brass fitting secured to the black iron pipe Note Flare to flare connections do not require Teflon tape or pipe sealant IMPORTANT Installation of Natural or LP gas should be done by a qualified installer service agency or gas supplier The appliance and its manual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of the s...

Страница 7: ...rom the bottom of the control box that houses the gas valve and module it should be a minimum if of 4 inches to the ground level See figure 1 Drainage is critical to ensure that water does not damage and valve components Never install the fire ring system below grade 11 CAUTION A minimum of 18 square inches of cross ventilation 2 sides is required to keep the components in good working order 12 Th...

Страница 8: ...e burner and control system should be tested before the media lava rock is installed NOTE If using optional 120V power adapter AF 4000ADP24 you must use a switch or a breaker that can be turned ON and OFF easily Normal operations are with battery power and nothing else would have to be done INSTALLATION OF BATTERY INTO TRANSMITTER You have one handheld transmitter model RCAF 3 and you will need to...

Страница 9: ...he control box See fig 9 The cover will slide down exposing the gas valve and control module 2 Find the black module attached to the inside of the control box Locate the Learn Button on the bottom of the module 3 Once the Learn button is located press and release the button once You will hear a beep indicating that the module is ready to receive a transmitter code See fig 10 4 Take the transmitter...

Страница 10: ... the optional 120V power adapter you must turn the switch or breaker ON If using the standard battery pack ensure batteries are installed and the Fire Pit is ready to operate 3 Press the ON button on the handheld transmitter You will hear the ignitor probe sparking light the gas and fire pit will come on WARNING Do not stand over Fire Pit during ignition or operation due to high surface tempera tu...

Страница 11: ...REV 10 10 12 Page REPLACEMENT PARTS 1 2 3 11 12 13 8 16 7 15 14 ON OFF HI LOW 17 SKYTECH SKYTECH SKYTECH SKYTECH 19 6 5 18 4 ...

Страница 12: ...t shown 1 ST3 100 1030 10 DSI Valve Box Assembly not shown 1 ST2 010 1010 11 Stainless DSI Fire Pit Valve Box Only 1 ST3 100 1020 13 Stainless DSI Fire Pit Valve Box Cover Only 1 ST3 100 1021 13 Control Module AF 5000MOD 1 Inside valve box 1 ST3 030 1039 14 AF 4025 DSI Gas Valve 5 0 WC Natural Gas 1 ST2 080 1025 15 1 2 Flex Gas Line 46 inch Length 1 T 200 9898 46 16 Air Shutter Orifice NG 13 Used ...

Страница 13: ... of Fault Warn users if the pilot is not successfully ignited in 15 seconds How to Clear Press OFF then ON buttons to re attempt ignition What to Check 1 Ensure gas supply is turned on 2 Ensure that the gas line is purged of air Air is common in the gas line if the appliance has just been installed has been disconnected then re connected to the gas line or if the appliance has been unused for an e...

Страница 14: ... operating range 8 Make sure that there is not a large metal obstruction between the remote transmitter and the control module Igniter Electrode Sparks Frequently During Operation 1 The control module will generate a spark at the igniter electrode if the system is in the ON position but does not sense a flame 2 Make sure that the flame sensor electrode is clean Soot buildup will insulate the elect...

Страница 15: ...ice air mixer for 19 20 pits using 18 inch firestar LP Conversion Kit MODEL FPB 25LPCK Brass orifice air mixer for 25 26 pits 24 inch firestar LP Conversion Kit The following accessories are available from your local firegear dealer distributor Each accessory comes with a separate installation manual Read each instruction thoroughly before installing FCC REQUIREMENTS NOTE THE MANUFACTURER IS NOT R...

Страница 16: ...ranty period Travel diagnostic cost service labor to repair the defect and freight charges on warranty parts to and from the factory will be responsibility of the owner Fire Gear LLC will not be responsible for labor charges and or damage incurred in installation repair and replace ment or for incidental or consequential damages This Limited Warranty does not cover any failures or operating diffic...

Отзывы: