background image

H- Burner Kit

REV. A  Page 16

COMMERCIAL APPLICATIONS – MANUFACTURED AFTER 12/02/2019 

 

BURNER SYSTEMS, BURNERS, COMPONENTS AND ACCESSORIES 

•    TWO (2) YEAR WARRANTY ON CONSTRUCTION AND MANUFACTURER DEFECTS 

•    TWO (2) YEAR WARRANTY - STAINLESS STEEL BURNERS AND PANS 

•    TWO (2) YEAR WARRANTY - BRASS BURNERS 

•    TWO (2) YEAR WARRANTY - GAS VALVE, SPARK IGNITER, PILOT ASSEMBLIES 

•    TWO (2) YEAR WARRANTY - AWS ELECONITC IGNITION SYSTEMS (24VAC, 30 VDC) 

•    TWO (2) YEAR WARRANTY – MT COMPONENTS (KEY VALVE) 

•    TWO (2) YEAR WARRANTY - REFRACTORY GAS LOG SETS  

•    FIVE (5) YEAR WARRANTY - READY TO FINISH/ANF FIRE PIT ENCLOSURES 

•    TWO (2) YEAR WARRANTY – SKYTECH MANUACFTURED OPTIONAL CONTROLS 

 

OUTDOOR FIREPLACE – KALEA BAY 

•    LIFETIME WARRANTY - CONSTRUCTION AND MANUFACTURER DEFECTS 

•    LIFETIME WARRANTY - STAINLESS STEEL COMPONENTS 

•    TWO (2) YEAR WARRANTY - GAS VALVE, PILOT ASSEMBLY, POWER SUPPLY, CONTROLS 

•    TWO (2) YEAR WARRANTY – SKYTECH MANUACFTURED OPTIONAL CONTROLS 

 

SANCTUARY SERIES – GFRC FIRE FEATURES 

•    THREE (3) YEAR WARRANTY - GFRC STRUCTURE 

•    REFER TO THE APPROPRIATE BURNER SYSTEM FOR WARRANTY 

WARRANTY COVERS MANUFACTURING DEFECTS OR STRUCTURAL FAILURE. SMALL STRESS CRACKS AND SURFACE 

CRAZING ARE A NATURAL OCCURRENCE IN GFRC PRODUCTS AND NOT COVERED BY WARRANTY

 

READY TO FINISH/ANF ENCLOSURES  

•    FRAME – LIFETIME WARRANTY ON CONSTRUCTION AND MANUFACTURER DEFECTS 

 

ACCESSORIES 

•    LIFETIME WARRANTY - CONSTRUCTION AND MANUFACTURER DEFECTS 

•    LIFETIME WARRANTY - STAINLESS STEEL COMPONENTS (LIDS, STAINLESS STEEL COVERS) 

•    ONE (1) YEAR WARRANTY – ESTOP1-OH, ESTOP2-5H WINDSHIELDS, HOSES AND REGULATORS 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание FG-H-2406SS

Страница 1: ...48 X 6 Burner FG H 4806SSK 48 X 6 Burner Kit 175 000 Btu s Installation and Operating Instructions IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS DO NOT ATTEMPT TO INSTALL OR OPERATE THIS APPLIANCE Warning For Outdoor Use Only INSTALLATION PRECAUTION Fire pit burners require a minimum 18 square inches per side of cross ventilation in an enclosure Failure to provide proper ventila...

Страница 2: ...t DANGER WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or other appliances Any LP cylinder not connected for use shall not be stored in the vicinity of this or other appliances WARNING Do not leave unattended during use Do not use for cooking Follow all gas leak procedures in this manual prior to operation WARNING Improper installation adjustmen...

Страница 3: ...re feature WE HIGHLY RECOMMEND COVERING ALL FIRE FEATURES WHEN NOT IN USE The use of a cover can lessen the impact of thermal spalling however heavy rains high humidity and the presence of moisture may still cause the media to pop ALWAYS USE CAUTION WHEN USING THE FIRE FEATURE Extra caution should be taken when lighting a fire feature when heavy rains high humidity and moisture are present Light t...

Страница 4: ...P at the burner orifice Flex line size and proper gas pipe sizing will also affect Btu s As a result your Btu s may vary slightly from Table 2 specifications BEFORE INSTALLING A H BURNER DETERMINE PAN SIZE TO BE USED The H Burners listed above are not provided with a burner pan for installation You must provide an appropriate non combustible burner pan to install the H Burner Suggested burner pans...

Страница 5: ...use a Propane tank less than 100lbs capacity IMPORTANT Installation of Natural or LP gas should be done by a qualified installer service agency or gas supplier This appliance must be isolated from the gas supply piping system by closing its manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psi 3 5kPa VENTILATION FOR NON COMBUST...

Страница 6: ...pe sizes required for the amount of BTU s for a new gas line installations If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have proper pressure This chart is for reference only we recommend you consult with a Licensed Plumber Gas Fitter or NFPA54 National Fuel Gas Code current edition for more details Length of Pipe in Feet...

Страница 7: ... provide ventilation to prevent moisture and provide an outlet for gas in the case of a gas leak 8 CAUTION A minimum of 18 square inches of cross ventilation opposite sides is required to keep the enclosure dry 9 These products are designed for outdoor use only Not approved for any indoor use or any enclosed space 10 This fire pit is designed to have Firegear Outdoors lava rock or glass media comp...

Страница 8: ...h the pan See Fig 4 then install the OAS and U3 8D S to the nipple connect inlet gas line as shown in Fig 5 7 8 to 1 Inch Center Hole Fig 4 Minimum center clearance hole in burner pan ALL H BURNER MODELS H BURNER ASSEMBLY CAUTION Do not assemble the OAS and U3 8D S until you are ready to install the H Burner into the burner pan The OAS is 1 in diameter and would not fit the recommended center hole...

Страница 9: ... Outdoors See replacement parts list in manual for model numbers INSTALLING KEY VALVE INSTALLATION OF LAVA ROCK MEDIA INTO BURNER PAN Install lava rock into the burner pan Ensure the lava rock is a 1 inch diameter for proper operation Note Do not pour Lava Rock directly from bag It should be placed naturally and NOT packed in tight Loose fitting is important to ensure robust flames Be sure rocks a...

Страница 10: ...ly Key Valve Side View Det a i l Fig 5 Typical installation NOTE Key valve and flexible gas lines are supplied Gas shut off is not supplied Note A 1 x 2 black iron or galvanized coupler nipple not supplied can be used as a spacer between the manual valve and the valve flange to add additional support to hold the manual key valve in place Key Valve Flange Non Combustible Wall Material Non Combustib...

Страница 11: ... use of the appliance 6 Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply Natural or L P gas line WARNING 1 This appliance is hot when operated and can cause severe burns if contacted 2 Do not burn any solid fuels in this appliance LIGHTING INSTRUCTIONS Key Fig 7 Inserting Key into Valve O N O F F Fig 6 Key valve flange Butane Lighter ...

Страница 12: ...Air Shutter for Natural Gas or LP Gas Fire Pits Refer to Table 2 on page 4 3 1 2 Flex Gas Line 28 inch Length used with all kits 1 T200 9898 28 4 Key Valve 1 BVL2S 4a Chrome Plated Flange Cover used with BVL2S key valve 1 CVR BVL2CP 5 12 inch Chrome Key used with all key valves 1 KEY PC 12 6 Flare to FIP U3 8D S 7 Flare to MIP U1 8D S Item Description Qty Part Number See the Firegear Outdoors cata...

Страница 13: ... A 90 elbow is not provided with the kit All NPT pipe threads must be sealed with approved gas Teflon tape or pipe compound Check for any gas leaks before presuming normal operation after conversion is complete CAUTION Ensure there is ventilation under the burner to provide fresh air for air shutter orifice Burner Pan GAS FLOW x 5 inch Nipple 113SS4 D5 OAS LP Orifice Flared Fitting U3 8D S x Coupl...

Страница 14: ...g to operate NOTE If a combustible type cover is used over the fire pit when not in use be sure to remove it before operation to prevent a severe safety hazard 5 Over time stainless steel parts can discolor when heated usually a golden or brown hue This discoloration is normal and does not affect the performance of the appliance FIRE PIT MAINTENANCE TROUBLE SHOOTING Symptom Remedy Fire pit won t l...

Страница 15: ...TY REFRACTORY GAS LOG SETS FIVE 5 YEAR WARRANTY READY TO FINISH ANF FIRE PIT ENCLOSURES FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS OUTDOOR FIREPLACE KALEA BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS FIVE 5 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONT...

Страница 16: ... BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS TWO 2 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS TWO 2 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS SANCTUARY SERIES GFRC FIRE FEATURES THREE 3 YEAR WARRANTY GFRC STRUCTURE REFER TO THE APPROPRIATE BURNER SYSTEM FOR WARRANTY WARRANTY COVERS MANUFACTURING DEFECTS OR ST...

Страница 17: ...efect on warranty parts to and from the factory will be the responsibility of the owner We will not be responsible for labor charges and or damage incurred in installation repair and replacement Firegear is not responsible for Issues related to gas or electrical installation The Limited Warranty is voided if not assembled installed and operated as intended This Limited Warranty does not cover any ...

Страница 18: ...r consequential damages so this limitation or exclusion may not apply to you We do not authorize any person or company to assume for it any other obligation or liability in connection with the sale installation use removal return or replacement of its equipment and or such representation are binding Firegear Outdoors 17322 Gothard Street Huntington Beach CA 92647 www firegearoutdoors com Phone 800...