Firegear B360EXSSA11-N Скачать руководство пользователя страница 12

 

12 

OPERATION 

 

 

FOR YOUR SAFETY 

– READ BEFORE LIGHTING 

 

 

 

 

FIGURE 27 

– REAR VIEW

 

 - REVOLUTION 360EXSS NATURAL GAS 

 

Shown in black steel 

– actual unit is constructed of 304 Stainless Steel 

 

 

!!!  WARNING  !!! 

Do not use this appliance if any part has been under water.  
Immediately call a qualified service technician to inspect the 
appliance, and replace any part of the control system and any 
gas control that has been under water. 

 
This appliance, depending on model, uses a piezo igniter, to 
light the safety pilot.  The piezo igniter is located above the gas 
valve control knob.  Pilots may also be lit by long hearth match, 
hand fire starter, or book match clip extender.  All units must 
be lit by a Safety Pilot.  Pilot is located at the rear, left-center of 
the unit.  ( See Figure 27, 28, & 29 )  
 
Follow these instructions exactly when lighting the appliance.  
BEFORE LIGHTING, smell around the appliance area for gas.  
Be sure to smell next to the floor, as LP gas is heavier than air 
and will settle to the floor.  Use only your hand to rotate the gas 
control knob.  Never use tools.  If the knob will not turn by 
hand, do not try to repair it; call qualified service technician or 
installer.  Force or attempted repair, may result in a fire or 
explosion.  

 

 

FIGURE 29 

– ODS PILOT 

 

OPERATION continued 

 

!!!  WARNING  !!! 

All gas burning appliances produce smoke and carbon 
monoxide gas during operation.  These fumes can be harmful 
if the appliance is used in any other than a fully vented, or 
certified vent-free fireplace. 

 

!!! WARNING !!! 

A fireplace screen must be in place when this appliance is in 
operation.  Unless other provisions for combustion air are 
provided, the screen shall have an opening(s) for introduction 
of combustion air. 

 

Содержание B360EXSSA11-N

Страница 1: ...adian Standards Association CSA certification numbers for the gas and ignition systems used with firegear outdoor gas log systems The valve systems are manufactured by Skytech II Inc The complete syst...

Страница 2: ...EVER use liquid propane gas in a natural gas unit or natural gas in a liquid propane unit DO NOT use solid fuel or lighter fluid in any gas appliance Keep appliance area clear and free from combustibl...

Страница 3: ...ons LOG FRONT DEPTH HEIGHT MINIMUM SET WIDTH IN IN IN VENT IN SIZE INCHES INCHES INCHES SQ INCHES FG 360A11 30 14 19 25 7 sq in FG 420A11 36 14 20 33 8 sq in FOR OUTDOOR USE ONLY MINIMUM FIREPLACE DIM...

Страница 4: ...afe Installation 12 or more Non combustible material Less than 12 Non combustible material must be extended to at least 8 with the installation of the optional fireplace hood If you can not extend non...

Страница 5: ...d with unvented gas logs WARNING Any modification to this unvented gas heater or its controls can be dangerous Improper installation or use of the heater can cause serious injury or death from fire bu...

Страница 6: ...onnected from the gas supply piping system during any system pressure test in excess of PSI 3 5 KPA Use a system manual shut off valve to shut off the gas supply to this gas appliance before continuin...

Страница 7: ...k steel actual unit is constructed of 304 Stainless Steel FIGURE 11 REVOLUTION BURNER ASSEMBLY ANGLE VIEW Shown in black steel actual unit is constructed of 304 Stainless Steel WHEN INSTALLING THE APP...

Страница 8: ...stable pipe wrenches one wrench on the gas stub and one wrench on the fitting remove the existing cap or gas jet assembly from the gas stub in your fireplace by turning the wrench on the gas cap in a...

Страница 9: ...Free Burner Systems use 1 The American Flame AF 1100 Series Valves AF 1110 shown here with remote solenoid shown separately in diagram All systems use only an ODS safety pilot with a thermocouple SEE...

Страница 10: ...R REAR VIEW FIGURE 17 HAND HELD REMOTE RECEIVER TOP VIEW IMPORTANT TERMINAL BLOCK CONNECTIONS FOR HAND HELD TRANSMITTER REMOTE RECEIVERS USE THE OUTSIDE TERMINAL BLOCK RECEPTACLES SEE FIGURE 16 17 WAL...

Страница 11: ...s Logs Box Two before continuing with FINAL SET UP step 2 2 Remove all contents from the Decorative Gas Log shipping container Box Two 3 Check the contents of the shipping container against the shippi...

Страница 12: ...unit See Figure 27 28 29 Follow these instructions exactly when lighting the appliance BEFORE LIGHTING smell around the appliance area for gas Be sure to smell next to the floor as LP gas is heavier t...

Страница 13: ...anual shut off valve and recheck all gas connections for leaks Do not continue until all leaks are corrected Once you are assured that there are no leaks proceed with step seven 7 7 Locate the pilot p...

Страница 14: ...wo 2 inches and allow the flame to burn for another thirty 30 minutes Continue this procedure at thirty 30 minute intervals for a total of three 3 hours MAINTENANCE SERVICE Your firegear Decorative Ga...

Страница 15: ...ASS ORIFICE STEM TYPE 20 THREAD HEX 420 NG OR S 37 5 37 BRASS ORIFICE STEM TYPE 20 THREAD HEX 360 NG PI 1 14 PIEZO IGNITER PIW 18 15 PIEZO IGNITER WIRE 18 REG 35 9 REGULATOR 3 5 W C NG REV EMB A COMMO...

Страница 16: ...E FROM REGULATOR TO VALVE LP ONLY OR S 52 5 52 BRASS ORIFICE STEM TYPE 20 THREAD HEX 420 LP OR S 53 5 53 BRASS ORIFICE STEM TYPE 20 THREAD HEX 360 LP PI 1 17 PIEZO IGNITER PIW 18 18 PIEZO IGNITER WIRE...

Страница 17: ...s When ordering parts first obtain the Model Number from the name plate on your equipment then determine the PART NUMBER not the Index Number and the part description of each part from the parts list...

Страница 18: ...Check gas supply pressure while pilot remains on Faulty Valve Replace Valve Faulty pilot or thermocouple Replace Safety Pilot Clogged or dirty burner ports Clean burner ports Faulty Regulator Replace...

Страница 19: ...covered by this Limited Warranty Before returning any parts contact firegear Customer Service Center If firegear confirms the defect and approves the claim firegear will replace such parts without cha...

Страница 20: ...20 www firegearusa com REVEXSSA11 2 0...

Отзывы: