Firegear AF-1100 VALVE SERIES Скачать руководство пользователя страница 3

3

SAFETY INFORMATION PERTINENT TO

UNVENTED APPLICATIONS continued

WARNING:

Any modification to this heater or its controls can

be dangerous.

DO NOT INSTALL HEATER UNTIL ALL NECESSARY
PROVISIONS ARE MADE FOR COMBUSTION AND
VENTILATION AIR. CONSULT THE WRITTEN
INSTRUCTIONS PROVIDED WITH THE HEATER FOR
INFORMATION CONCERNING COMBUSTION AND
VENTILATION AIR. IN THE ABSENCE OF INSTRUCTIONS,
REFER TO THE

NATIONAL FUEL GAS CODE, ANSI Z223.1,

SECTION 5.3 OR APPLICABLE LOCAL CODES.

This heater is equipped with an ODS ( Oxygen Depletion
Sensor ) SAFETY PILOT SYSTEM designed to turn off the
heater if not enough fresh air is available.

DO NOT TAMPER WITH SAFETY PILOT SYSTEM!

If the heater shuts off, DO NOT re-light until you have provided
fresh air to the appliance.

If heater keeps shutting off, have it serviced. Keep burner and
control compartment clean.

CARBON MONOXIDE POISONING MAY LEAD TO DEATH

Early signs of carbon monoxide poisoning resemble the flu,
with headache, dizziness and/or nausea. If you have these
symptoms, heater may not be working properly.

GET FRESH AIR AT ONCE! HAVE HEATER SERVICED!

Some people – pregnant women, persons with heart or lung
disease, anemia, those under the influence of alcohol, those at
high altitudes – are more affected by carbon monoxide than
others.

!!! WARNING !!!

Improper installation, adjustment, alteration, service or
maintenance, can cause property damage, personal injury or
loss of life. Refer to the owner’s information manual, provided
with this appliance. Installation and service must be performed
by a qualified installer, service agency or the gas supplier.

!!! WARNING !!!

When used without adequate combustion and ventilation air,
heater may give off excessive CARBON MONOXIDE, an
odorless, poisonous gas.

!!! WARNING !!!

Before you install this appliance, have a professional installer
audit the conditions of combustion and ventilation air.
Additional ventilation may be required in conditions of tight
construction.

FIREGEAR REVOLUTION FG-360A11 GAS

LOG HEARTH KIT SPECIFICATIONS

NATURAL GAS -

RATED PRESSURE – 3.5” W.C.

MINIMUM GAS

MAXIMUM GAS

ORIFICE

BTU/HR

PRESSURE

PRESSURE

SIZE

INLET

4.5” W.C.

10.5” W.C.

#37

29,000

Operating Pressure of Regulator per rate – 3.5” W.C.

LIQUID PROPANE

- RATED PRESSURE – 10.0” W.C.

MINIMUM GAS

MAXIMUM GAS

ORIFICE

BTU/HR

PRESSURE

PRESSURE

SIZE

INLET

11.0” W.C.

13.0” W.C.

#53

24,000

Operating Pressure of Regulator per rate – 10.0” W.C.

FIREGEAR REVOLUTION FG-420A11 GAS

LOG HEARTH KIT SPECIFICATIONS

NATURAL GAS -

RATED PRESSURE – 3.5” W.C.

MINIMUM GAS

MAXIMUM GAS

ORIFICE

BTU/HR

PRESSURE

PRESSURE

SIZE

INLET

4.5” W.C.

10.5” W.C.

#35

32,000

Operating Pressure of Regulator per rate – 3.5” W.C.

LIQUID PROPANE

- RATED PRESSURE – 10.0” W.C.

MINIMUM GAS

MAXIMUM GAS

ORIFICE

BTU/HR

PRESSURE

PRESSURE

SIZE

INLET

11.0” W.C.

13.0” W.C.

#52

28,000

Operating Pressure of Regulator per rate – 10.0” W.C.

HIGH ALTITUDE DERATE

In the U.S.A., input BTU shall be de-rated 4% ( 1 orifice
size ) per 1000 ft. for altitudes above 2000 ft.. In
Canada, input BTU shall be de-rated 10% ( 2 orifice
sizes ) at altitudes from 2000 ft. to 4500 ft..

MINIMUM FIREPLACE DIMENSIONS

MINIMUM FIREPLACE DIMENSIONS
MASONRY BUILT FIREPLACES

Chimney Height minimum of 6 feet – Vented Applications

LOG

FRONT

DEPTH

HEIGHT

MINIMUM

SET

WIDTH IN

IN

IN

VENT IN

SIZE

INCHES

INCHES

INCHES

SQ INCHES

FG-360A11

30"

14"

19"

25.7 sq. in.

FG-420A11

36"

14"

20"

33.8 sq. in.

Содержание AF-1100 VALVE SERIES

Страница 1: ...information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life This is an un vented gas fired heater It uses air Oxygen from...

Страница 2: ...and the products of combustion of such fuels contain chemicals known to the State of California to cause cancer birth defects and or other reproductive harm This warning is issued pursuant to Californ...

Страница 3: ...rvice agency or the gas supplier WARNING When used without adequate combustion and ventilation air heater may give off excessive CARBON MONOXIDE an odorless poisonous gas WARNING Before you install th...

Страница 4: ...insure safe installation Failure to follow these instructions exactly can create a fire hazard SIDEWALL CEILING CLEARANCES FIGURE 2 The sides of the fireplace opening must be a minimum of six 6 inche...

Страница 5: ...he mantel FLOOR CLEARANCES If installing the appliance at floor level the minimum clearance to combustible material is six 6 inches SEE FIGURE 5 FIGURE 5 EXAMPLE OF COMBUSTIBLE MATERIAL DO NOT attach...

Страница 6: ...ted room heater having an input rating of more than 6 000 Btu per hour shall not be installed in a bathroom INSTALLATION INFORMATION UNVENTED APPLICATIONS WARNING This appliance is for installation on...

Страница 7: ...tional Fuel Gas Code This appliance and its individual shut off valve must be disconnected from the gas supply piping system during any system pressure test in excess of PSI 3 5 KPA Use a system manua...

Страница 8: ...for the gas connection with the exception of ember material and log placement IMPORTANT BEFORE YOU BEGIN Audit the gas pressure at the fireplace stub to insure proper minimum gas pressure see the spe...

Страница 9: ...sooting SEE FIGURE 12 NOTE Special care is required if you are installing the appliance into a sunken fireplace The fireplace floor must be raised using non combustible materials to allow access to th...

Страница 10: ...will be necessary for your distance run 1 Using a Jeweler s Phillips screwdriver install the stripped ends of connecting wire into the screw terminal block on the rear of the remote receiver FOR HAND...

Страница 11: ...HAND HELD TRANSMITTER REMOTE RECEIVERS USE THE OUTSIDE TERMINAL BLOCK RECEPTACLES SEE FIGURE 16 17 WALL MOUNT REMOTE RECEIVER See the instructions packaged with the remote system for directions on pr...

Страница 12: ...eeded to cover the area and the use of too much will retard the yellow flame and eliminate the glow Apply just enough to obtain a slow glow DO NOT PLACE GLOWING EMBERS DIRECTLY ON THE BURNER PORTS THI...

Страница 13: ...ctive wrapping from the gas logs 5 Arrange the decorative gas logs on the burner base according to the instructions packaged with the gas logs 6 Place the Lava Rock cinders around the Grate Burner ass...

Страница 14: ...the gas valve control knob Pilots may also be lit by long hearth match hand fire starter or book match clip extender All units must be lit by a Safety Pilot Pilot is located at the rear left center of...

Страница 15: ...ty information in this manual LIGHTING THE PILOT 2 Push in the gas control knob slightly and turn it in a clockwise direction to the OFF position DO NOT FORCE NEVER USE ANY TOOL TO ROTATE THE GAS CONT...

Страница 16: ...tructions given for curing the logs to avoid cracking the logs with continued use After the initial lighting of the burner system adjust the flame to about two 2 inches Allow the flame to burn for thi...

Страница 17: ...420 NG OR S 37 5 37 BRASS ORIFICE STEM TYPE 20 THREAD HEX 360 NG PI 1 14 PIEZO IGNITER PIW 18 15 PIEZO IGNITER WIRE 18 REG 35 9 REGULATOR 3 5 W C NG REV EMB A COMMON PARTS PAGE REVOLUTION EMBERS ROCK...

Страница 18: ...S 52 5 52 BRASS ORIFICE STEM TYPE 20 THREAD HEX 420 LP OR S 53 5 53 BRASS ORIFICE STEM TYPE 20 THREAD HEX 360 LP PI 1 17 PIEZO IGNITER PIW 18 18 PIEZO IGNITER WIRE 18 REG 10 11 REGULATOR 10 0 W C LP...

Страница 19: ...and descriptions When ordering parts first obtain the Model Number from the name plate on your equipment then determine the PART NUMBER not the Index Number and the part description of each part from...

Страница 20: ...HELD ON OFF REMOTE FG LT TH2 HAND HELD ON OFF THERMOSTAT REMOTE FG LMF SM1 or 2 HAND HELD ON OFF HI MED LOW FLAME REMOTE FIREGEAR WALL MOUNT REMOTE SYSTEMS FG WS LT WIRED WALL SWITCH FG WWS LT WIRELE...

Страница 21: ...Check gas supply pressure while pilot remains on Faulty Valve Replace Valve Faulty pilot or thermocouple Replace Safety Pilot Clogged or dirty burner ports Clean burner ports Faulty Regulator Replace...

Страница 22: ...ited Warranty does not cover any failures or operating difficulties due to accident abuse misuse alteration misapplication vandalism improper installation or improper maintenance or service or failure...

Страница 23: ...23 NOTES...