Installation to Wall
When fixing the heater to a wall, ensure hinges are in the underside
so that the lid hands down in the open position.
Minimum required distances:
a) 500mm from the side wall
b) 500mm from the ceiling
c) Installation height above 1.8M
The heater must be fixed to a wall with the bracket supplied to allow
adequate ventilation.
Never fix or place heater near flammable or combustible materials.
Generally heaters must be placed at a safe distance (clear space) of
at least 2.0m from combustible materials and glass walls. If installed
in workshops or garages where inflammable or combustible paints
are used, the heaters must be installed at a distance of at least 4.0m
from the source of danger.
If the heaters are placed in areas where spray painting of any
description is taking place, they should not be used during the
painting operations.
Never use the heater in particularly dusty and explosive areas.
Connection to 220-240 Volts Power Supply
It is important to ensure that the electricity supply is of adequate
capacity for the electrical load required by the appliance being
installed.
These appliances must be earthed.