0
5
1
0
1
5
20
25
30
35
4
0
4
5
50
0
5
1
0
1
5
20
25
30
35
4
0
4
5
50
9.5 Paramete r number and descriptio n are liste d in th e fo llowing ta ble.
The manometer is a kind of high pressure equipment, when the heat pump is on, the manometer pointer
2
would point to the pressure value of refrigerant, the max. value of protection is 42kg/Cm . When the heat pump
°
is off, the pointer would point to the same value as actual ambient temperature (e.g. 28 C) and related air
2
pressure (e.g.18kg/ Cm ).
Please check the manometer when you restart the heat pump after not using for a long time, if it shows
ambient temperature valv
e is smaller than 2
, i
t means
that refrigerant has leaked a lot, and you need to confirm with professional engineer as soon as possible.
°
°
C
(
When
the
ambient temp. is higher than 2 C
)
Remark
:
the machine off code(The No. 13,
parameter in the previous table):
2:Water tank temp. sensor breakdown
3:Evaporator coil temp. sensor breakdown
4:Discharge temp. sensor breakdown
5:Discharge temp.is too high, thanshop the machine
11:Anti-frozen finishing,than shop the machine
12:High-pressure switch cutting
13:Meet set temp
14:Controller power off
No. 32
19:Water flow switch breakdown
No.
Content
Scope
Default
Memorized station
0
The incoming electric memorized sign
0-no effective 1-effective
1
The main board
1
Daily circulation sign
0-no effective 1-effective
1
the wire control panel
2
the setting area X
2
℃~
10
℃,
Unit
:℃
3
The main board
3
the setting area Y
0
℃~
3
℃,
Unit
:℃
0
The main board
4
The interval for defrosting
15
~
99
,
Unit
:
minute
45
The main board
5
Defrosting-on temperature
-9
~
5
℃,
Unit
:℃
0
The main board
6
Defrosting-off temperature
5
~
20
℃,
Unit
:℃
10
The main board
7
Compressor’s exhaust air protection
90
~
120
℃,
Unit
:℃
b8: means 118
℃
The main board
8
Evaporator coil temperature 1
Unit
:℃
Scope
:
-9
℃
-80
℃
No Setting
9
Discharge gas temperature 1
Unit
:℃
98: means 98
℃
A8: means 108
℃
b8: means 118
℃
No Setting
10
ambient temperature
Unit
:℃
Scope
:
-9
℃
-80
℃
No Setting
11
Compressor continuous running time
Unit
:
minute Scope
:
0-99
No Setting
12
Fan continuous running time 1/4
Unit
:
Second
No Setting
13
Compressor auto-off code 1
No Setting
14
On-off imported state
Especial
:
sixteen
No Setting
24
Auxiliary heat source
0-no effective 1-effective
0
The main board
25
Water
tank
temp./water
outlet
temp.
compensation
-5
~
5
℃,
Unit
:℃
1
The main board
29
Evaporator coil temperature 2
Unit
:℃
Scope
:
-9
℃
-80
℃
No Setting
32
Compressor auto-off code 2
No Setting
37
Discharge gas temperature 2
Unit
:℃
98: means 98
℃
A8: means 108
℃
b8: means 118
℃
No Setting
48
Start ambient temp.(auxiliary heat source) 2
~
15
℃,
Unit
:℃
7
The main board
20:Defrosting preparation
21:Defrosting finish
22:Error phase or lack of phase with power supply,
then shop the machine
27:Low-pressure switch cutting
22:High-pressure switch cutting during water tank
temp. is high
32:High-pressure switch cutting during dofrosting
Hot Water Series
36
9.6