![Fired Up Corporation BEF0001 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/fired-up-corporation/bef0001/bef0001_safety-manual_2291460013.webp)
1 3
SECTION 03
FITTING AN INSET FIRE
Installing the fire where a stone or marble back panel is used
1. For solid walls, drill
the 2 holes approxi-
mately 35mm deep
using a 6mm
diameter drill bit.
Note if fitting the fire
to plaster board with
a cavity behind then
propriety wall fixings
(not supplied) will be
required.
3. Pass cable tie
through the larger
hole on the fire
body trim,
ensruing that
the head of
the cable tie
does not pass
through this
hole.
4. Pass cable tie
through the
hook of
the threaded
insert,
in a clockwise
direction.
5. Threading the
cable tie through
the second hole in
the fire body, and
attach through the
main head of the
tie, pulling to the
left to tighten the
fire into postition.
6. Once the
cable tie has has
sufficent tension
applied, the
excess cable can
be pushed neatly
through the
larger hole to be
concealed out of
view.
570mm
2. Insert wall plug
into wall, then
tighten the hook
screwthread into
the wall plug.