Firecraft Superior Standard BBV-42REN Скачать руководство пользователя страница 2

2

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

TABLE OF CONTENTS

Introduction ..................................... page

2

General Information ......................... page

2

Operation/Care of Your Appliance .... page

3

Damper & Outside Air Controls ....... page

5

Maintenance .................................... page

6

Millivolt Appliance Checkout ............ page

6

Electronic Appliance Checkout ......... page

6

Maintenance Schedule ..................... page

7

Log and Rockwool Placement ......... page

8

Wiring Diagrams .............................. page

9

Lighting Instructions – Millivolt ....... page 10

Lighting Instructions – Electronic .... page 12

Troubleshooting Guide – Millivolt ..... page 14

Troubleshooting Guide – Electronic .. page 15

Warranty .......................................... page 16

Product Reference Information ....... page 16

Replacement Parts .......................... page 16

Accessory Components ................... page 17

Replacement Parts List ..................... page 18

WARNING:  IMPROPER INSTALLATION,
ADJUSTMENT, ALTERATION, SERVICE
OR MAINTENANCE CAN CAUSE INJURY
OR PROPERTY DAMAGE.  REFER TO THIS
MANUAL.  FOR ASSISTANCE OR ADDI-
TIONAL INFORMATION CONSULT A
QUALIFIED INSTALLER, SERVICE
AGENCY OR THE GAS SUPPLIER.

These appliances are designed to operate on
natural or propane gas only. The use of other
fuels or combination of fuels will degrade the
performance of this system and may be dan-
gerous.

Input of appliance is 30,000 BTU/HR.

WARNING:  THESE FIREPLACES ARE
VENTED DECORATIVE GAS APPLIANCES.
DO NOT BURN WOOD OR OTHER MATE-
RIAL IN THESE APPLIANCES.

CONGRATULATIONS!

In selecting this SUPERIOR B-vented gas appliance you have chosen the finest and most
dependable fireplace to be found anywhere.  A beautiful, prestigious, alternative to a
wood burning fireplace.  Welcome to a Family of tens of thousands of satisfied SUPERIOR
Fireplace Owners.

Please read and carefully follow all of the instructions found in this manual.  Please pay
special attention to the safety instructions provided in this manual.  The Homeowner's
Care and Operation Instructions included here will assure that you have many years of
dependable and enjoyable service from your SUPERIOR product.

INTRODUCTION

The millivolt appliances are designed to oper-
ate on either natural or propane gas. A millivolt
gas control valve with piezo ignition system
provides safe, efficient operation.

The electronic appliances are designed to op-
erate on either natural or propane gas. An
electronic direct spark ignition system pro-
vides safe, efficient operation. External electri-
cal power is required to operate these units.

These appliances comply with National Safety
Standards and are tested and listed by (Report
No. J99025850) to ANSI Z21.50b - 1998 (in
Canada, CAN/CGA-2.22b-M98 as vented gas
fireplaces.

Installation must conform to local codes. In
the absence of local codes, installation must
comply with the current National Fuel Gas
Code, ANSI Z223.1 (NFPA 54). (In Canada, the
current CAN/CGA B149 installation code.)  Elec-
trical wiring must  comply with local codes.  In
the absence of local codes, installation must
be in accordance with the National Electrical
Code, NFPA 70 - (latest edition). (In Canada,
the current CSA C22.1 Canadian Electric Code.)

DO NOT ATTEMPT TO ALTER OR MODIFY
THE CONSTRUCTION OF THE APPLIANCE OR
ITS COMPONENTS. ANY MODIFICATION OR
ALTERATION MAY VOID THE WARRANTY,
CERTIFICATION AND LISTINGS OF THIS UNIT.

GENERAL INFORMATION

Note: 

Installation and repair should be per-

formed by a qualified service person. The
appliance should be inspected annually by a
qualified professional service technician. More
frequent inspections and cleanings may be
required due to excessive lint from carpeting,
bedding material, etc. It is imperative that the
control compartment, burners and circulating
air passage ways of the appliance be kept
clean.

S'assurer que le brùleur et le compartiment
des commandes sont propres.  Voir les in-
structions d'installation et d'utilisation qui
accompagnent l'apareil.

Provide adequate clearances around air open-
ings and adequate accessibility clearance for
service and proper operation. Never obstruct
the front openings of the appliance.

Due to high temperatures the appliance should
be located out of traffic and away from furni-
ture and draperies.  Locate furniture and win-
dow coverings accordingly.

Nominal operating pressures for the manifold
side of the gas control system are; 3.5 inches
water column (6.54 MmHg) for natural gas
models and 10 inches water column (18.69
MmHg) for propane gas models.

Do not use these appliances if any part has
been under water. Immediately call a qualified,
professional service technician to inspect the
appliance and to replace any parts of the
control system and any gas control which
have been under water.

Ne pas se servir de cet appareil s'il a été plongé
dans l'eau, complètement ou en partie.  Appeler
un technicien qualifié pour inspecter l'appareil
et remplacer toute partie du système de contrôle
et toute commande qui ont été plongés dans
l'leau.

Gas

Orifice

Type

Size

Elevation

0 - 4500'

(0 - 1370 m)

0 - 4500'

(0 - 1370 m)

Natural

Propane

(0.065)

#36

(0.106)

Содержание Superior Standard BBV-42REN

Страница 1: ...ING IFTHEINFORMATIONINTHISMANUAL IS NOT FOLLOWED EXACTLY A FIRE OR EXPLO SION MAY RESULT CAUSING PROPERTY DAM AGE PERSONAL INJURY OR LOSS OF LIFE POURVOTRES CURIT Nepasentreposerniutiliser d essenceni...

Страница 2: ...ts These appliances comply with National Safety Standards and are tested and listed by Report No J99025850 to ANSI Z21 50b 1998 in Canada CAN CGA 2 22b M98 as vented gas fireplaces Installation must c...

Страница 3: ...d ornau sea If you have these signs obtain fresh air immediately Turn off the gas supply to the appliance and have it serviced by a qualified professional as it may not be operating correctly WARNING...

Страница 4: ...fore re light ing refer to the lighting instructions in this manual Instructions are also found on a pull out panel located on the floor of the appliance 5 Always keep the appliance area clear and fre...

Страница 5: ...actuator forward to open the combustion air door and push it back to close To lock the outside air door closed ensure the actuator is pushed all the way back then push the end of the actuators to the...

Страница 6: ...ICAL POWER BEFORE SERVICING THE APPLIANCE Millivolt Appliance Checkout The pilot flame should be steady not lifting or floating Flame should be blue in color with traces of orange at the outer edge Th...

Страница 7: ...g Person Procedure Inspecting Cleaning Burner Logs and Controls Check Flame Patterns and Flame Height Inspecting Cleaning Pilot and Burner Checking Vent System Appliance Checkout Replacing Rockwool Em...

Страница 8: ...es Figure 11 Spread along the front edge of the front burner Do not use more than is necessary When properly positioned the rockwool will unevenly cover approximately 85 of the gap between the front b...

Страница 9: ...ile TH TP TH TP Limit Switch 1 If any of the original wire as supplied must be replaced 1 it must be replaced with Type AWM 105 C 18 GA wire 2 120V 60Hz Less than 3 amps BK Junction Box Transf 120 V 2...

Страница 10: ...l switch OFF The pilot will remain lit for normal service 2 For complete shutdown turn remote wall switch to OFF 3 Access the lower control compartment 4 Depress gas control knob slightly and turn clo...

Страница 11: ...r de l apareil ainsi que pr s du sol certains gaz tant plus lourds que l air descendent au niveau du sol VOICI CE QUE VOUS DEVEZ FAIRE SI VOUS D CELEZ UNE ODEUR DE GAZ teignez toute flamme visible Ouv...

Страница 12: ...use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which ha...

Страница 13: ...faire inspecter l appareil et remplacer toute pi cedusyst meder glageoucommandedugazquia t sous l eau 1 ARR TEZ Lisez les consignes de s curit au verso de cette plaque 2 Tournez l interrupteur mural l...

Страница 14: ...k If gap measures replace pilot Figure 8 Check inlet gas pressure It should be within the limits as marked on the rating plate Clean or replace pilot orifice Check pilot flame it must impinge on therm...

Страница 15: ...heck For Proper Voltage At Control Harness See Insert A Voltage Should Be 24V Between Thermostat Or Pressure Switch And 24V Common And 24V Hot Line Voltage Power Low Voltage Transformer Limit Controll...

Страница 16: ...e part 5 The quantity required 6 The installation date of the appliance If you encounter any problems or have any questions concerning the installation or appli cation of this system please contact yo...

Страница 17: ...spressed asignallightilluminates briefly to verify that a signal has been sent The Model RCK S is designed to operate with all millivolt ignition systems as well as elec tronic ignition systems It may...

Страница 18: ...ssembly LB 97338 1 LB 97338 1 10 Burner Orifice 18L4001 1 LB 558741 1 11 Bag of Rockwool 88L53 1 88L53 1 GAS CONTROLS ELECTRONIC Natural Propane No DESCRIPTION Part No Qty Part No Qty 30 Gas Valve Hon...

Страница 19: ...19 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE REPLACEMENT PARTS 24 22 20 3 4 5 6 7 2 1 31 30 10 REF 10 21 25 26 23 33 9 8 11 32 c b a d e...

Страница 20: ...2000 4325 Artesia Avenue Fullerton CA 92833 714 521 7302 FireCraft Technologies reserves the right to make changes at any time without notice in design materials specifications prices and also to disc...