background image

 

  

 

 
 
 

MULTIFUEL RANGE COOKER 

 

 
 
 

Содержание Multifuel Range Cooker

Страница 1: ...1 MULTIFUEL RANGE COOKER...

Страница 2: ...fore Lighting 11 4 10 Commissioning 11 4 11 CO Alarms 12 5 0 OPERATING INSTRUCTIONS 5 1 Fuels 13 5 2 Lighting and Controlling 13 5 2 1 Wood 14 5 2 2 Smokeless Fuel 14 5 2 3 Overnight Banking 14 5 3 Co...

Страница 3: ...THE APPLIANCE IS HOT WHILE IN OPERATION AND REMAINS HOT FOR A PERIOD AFTER USE ENSURE THAT CHILDREN OR INFIRM PERSONS ARE SUPERVISED AT ALL TIMES WHILE APPLIANCE IS HOT UNTIL COOLED THOROUGHLY Do not...

Страница 4: ...out in the warranty must be adhered to a All claims under the warranty must be received within 5 years from the date of installation b The range cooker must be installed and commissioned by a HETAS ap...

Страница 5: ...ntinuous Minimum safe distance from combustible materials To rear 135mm and sides 0mm Unit Weight Empty 480kg Water Content 65 litres Maximum boiler operating pressure 3 bar The appliance is capable o...

Страница 6: ...6 4 2 SPECIFICATION...

Страница 7: ...is not installed operated maintained properly a house fire may result ADDITIONAL MATERIAL SAFETY ITEMS Handling Adequate facilities must be available for loading unloading and site handling Fire Ceme...

Страница 8: ...u have been drinking alcohol or taking medication that makes you drowsy IF OIL CATCHES FIRE WHILE COOKING and the fire is well established Get out of the house Close all doors behind you Dial 999 Do n...

Страница 9: ...alculated in accordance with EN13384 1 A minimum clearance of 1m above any obstruction within a 7 6m radius should be achieved if down draughts are to be avoided Where a standard chimney is not availa...

Страница 10: ...Fit the appliance into the opening making sure it is central 4 Make the connections to the boiler and ensure the primary flow pipe rises from the boiler to so that no air is trapped in the boiler 5 Dr...

Страница 11: ...ure that all controls are installed to building regulations Radiators can be fitted with thermostatic or manual valves Please note no valves must be fitted to radiators where they act as the heat leak...

Страница 12: ...ntrols The instruction manual should remain with the householder 4 11 CO ALARMS Building Regulations require that whenever a new or replacement fixed multifuel wood biomass appliance is installed in a...

Страница 13: ...e the risk of a chimney fire Well seasoned logs can have approximately twice the CV of unseasoned green logs Hard wood logs are denser than soft wood logs and tend to burn for a longer period of time...

Страница 14: ...mary and Secondary Air The appliance has two air setting controls namely primary and secondary Please refer to image below for location of these controls Both controls have settings in the range of 1...

Страница 15: ...installation 1 If the fuel in the firebox is exhausted prematurely the thermostat setting is too high and should be reduced 2 If the fuel does not burn but dies out the thermostat setting should be in...

Страница 16: ...safety guards are in place where children or infirm people are in the area 5 3 1 DOORS AND SHELVES To Open Doors Lift the door upwards and outwards to release from latch To Move Shelves Lift the shelf...

Страница 17: ...late is for flue cleaning and must not be removed for cooking Keep the hot plate clean with a wire brush NOTE To obtain optimum hot plate performance for fast boiling or hotplate cooking fuel the fire...

Страница 18: ...n the thermostat Cooker Control As soon as the fire produces flame close the flue chamber damper Do not allow the fire to run away The temperature of the oven should now rise steadily When it reaches...

Страница 19: ...vailable to customers that have been tested on vitreous enamelled components without causing damage These products can be purchased at hardware or convenient stores The cookers surfaces should be clea...

Страница 20: ...y are worn they should be replaced 6 3 WHEN NOT IN USE In the summer months or anytime that the range cooker is not being used for a long period of time clean out the inside thoroughly and open the pr...

Страница 21: ...TION If there is a possibility that a part of the heating system may be frozen you should not light the cooker until you are confident that the system is free of ice has no leaks and water is able to...

Страница 22: ...djustments may be required OVERHEATING In the event that the range cooker should over heat please close off dampers and run hot water to dissipate some heat from the cooker RADIATORS NOT HEATING INTER...

Страница 23: ...s Appliance linked to heating system in accordance with regulations distance from appliance to cylinder not exceeding 7 8m Sufficient Air Requirements room air vent installed minimum 4 or 100mm Chimne...

Страница 24: ...g Solutions Central Avenue Lee Mill Industrial Estate Nr Ivybridge Devon PL21 9PE United Kingdom Tel 44 0 1752 691177 Fax 44 0 1752 691131 Email sales firebirduk co uk Firebird Heating Solutions Shean...