Firebird Enviromax Condensing Range
3
10
3.2 - SYSTEM
Firebird Enviromax System C Model
Dimensions (mm)
Model Output Weight
Dime
n
sio
n
s(mm)
E
n
vi
r
o
m
ax
Kw/h
r
kg
H
W
D
A
B
C
E
F
G
System
C20
143
845 442 610 753 221 157 94 124 -
System
C26
146
845 442 610 753 221 157 94 124 -
System
C35
149
845 442 610 753 221 157 94 124 -
System
C44
235
1046 660 852 914 232 157 100 125 236
System
C44
System
C20 - C35
E
Top View
H
W
D
A
F
C
B
E
40
40
695
35
F
r
o
n
t View
Side View
F
r
o
n
t View
Side View
w
H
D
A
G
F
E
B
C
Top View
Copper Pipe Not Plastic to be used for a minimum of 1 metre off the boiler
Boiler Model
C20/26
C35
C44
Max Heat Output
Kw
20/26
35
44
Btu/h (‘000)
68/89
119
150
CONNECTIONS
Heating Flow
1” Bsp
1” Bsp
1
1
/
2
” Bsp
Heating Return
1” Bsp
1” Bsp
1
1
/
2
” Bsp
Drain Off Cock
1
/
2
”
Bsp
.
1
/
2
”
Bsp
.
1
/
2
”
Bsp
.
Safety Pressure Relief valve outlet (Copper)
1
/
2
”
Bsp
.
1
/
2
”
Bsp
.
1
/
2
”
Bsp
.
Condense Drain Off Connection.
3
/
4
”
Bsp
. Female
Circulating Pump
(Grundfos)
25/60
25/60
25/80
Boiler integral Expansion
12 litres
12 litres
18 litres
Vessel Normal Capacity
pre-charged to 1 bar.
WATER CONTENT
Water Content Boiler
24
24
45
FLUE (Indoor Boilers)
Concentric Flue
Balanced Flue Assembly
(mm)
125 (5”)
125 (5”)
155 (6”)
Conventional flue Socket.
(mm)
130 id.
130 id.
155 id.
Flue Draught Reqd.
(Min WG.)
0.040”
0.040”
0.040”
Conventional Flue
(Max WG.)
0.15”
0.15”
0.15”
Pressure Jet Oil Burners
RIELLO RDB 2.2 up to C35
&
RIELLO RDB 4.2 up to C58 - C73
Fuel
35 second Gas Oil
Electrical Supply
230v. AC 50Hz To be fused at 5amp.
TEMPERATURE CONTROL
Boiler Central Heating Control
60˚C - 80˚C+- 3˚C
Boiler Safety Limit
110˚C +- 3˚C
Tank (DHW)- Fixed
78˚C +- 3˚C
Early Alert - Fixed
87˚C +- 3˚C
Over-run - Fixed
93˚C +- 3˚C
HEATING SYSTEM (SEALED)
Fit in accordance with BS 7074
Part 1, BS 5449, OFTEC Standards, etc
Max. Operating Pressure
2.5 Bar
Max. System Pressure cold
1.5 Bar
Min. System Pressure cold
0.5 Bar + 0.3 Bar
Boiler Test Pressure
4.5 Bar
Safety Valve Operating Pressure
3 Bar
WATER SIDE RESISTANCE
Flow Rate To Give A Nominal Output At 10k Differential
Flow Rate Measured
(Kg h
-1
)
2874.24
Waterside Resistance
(mbar)
0.18
Flow Rate To Give A Nominal Output At 20k Differential
Flow Rate Measured
(Kg h
-1
)
1522.92
Waterside Resistance
(mbar)
0.19
Guidelines for Sealed System Installation -
See section 3.2, 4, 5 & 6
ROS PRINTERS
TEL: 064-6631233
PROOF
Содержание Enviromax
Страница 2: ...ROS PRINTERS TEL 064 6631233 PROOF...
Страница 51: ...ROS PRINTERS TEL 064 6631233 PROOF...