FireBird Enviromax Popular C26 Скачать руководство пользователя страница 22

4

4.3 systeM CondensIng BoIler - teCHnICal detaIls

22

3

1

2

6

7

4

5

17

14

13

8

9

10

15

12

18

21

19

20

18

16

11

For burner parts refer to burner manual

No.

Qty Description

26 kW

35 kW

1

4

Tube baffle

BA110907

BA110907

2

5

Tube baffle single

BA110908

BA110908

3

4

Smoke baffle

BA212028/BA212122

BA212028/BA212122

4

1

Door seal

ACC035GRA

ACC035GRA

5

1

Door duroboard

ACC035GSK

ACC035GSK

6

1

Flue gasket

ACC000FRG

ACC000FRG

7

1

Stat pocket

ACC003PKT

ACC003PKT

8

1

Condensate trap

ACC000TRP

ACC000TRP

9

1

Condensate hose

ACC000FLX

ACC000FLX

10

1

Heat deflector

ACC000HTD

ACC000HTD

11

1

Air hose

ACC000SSH

ACC000SSH

12

1

Control panel

314734

314734

13

1

Casing left side

214744

214744

14

1

Casing side cover

214748

214748

15

1

Casing right side

214745

214745

16

1

Casing top support

214749

214749

17

1

Casing front

214746

214746

18

2

Side flue blank

114731

114731

19

1

Casing top

214750

214750

20

1

Top flue blank

114730

114730

21

1

Casing back

214747

214747

22

1

Pressure vessel

ACC012PVL

ACC012PVL

22

Содержание Enviromax Popular C26

Страница 1: ...This manual must remain with the householder once installation is complete HEATING SOLUTIONS ENVIRONMENT INNOVATION TECHNOLOGY Technical Manual Condensing BoileR...

Страница 2: ...mbustion Air Requirements 14 3 5 Liquid Fuel Supply 15 4 SYSTEM Condensing BOILER 4 1 End User Information 16 4 2 Installer Guidelines 19 4 3 Technical Details 21 5 SYSTEMPAC Condensing BOILER 5 1 End...

Страница 3: ...ace the critical advantage provided by training and years of experience Firebird domestic condensing boilers are highly efficient and are all ErP A rated Energy related Products They use less fuel and...

Страница 4: ...be sought following eye contact or prolonged reddening of the skin The small quantities of adhesives and sealants used in the product are cured They present no known hazards when used in the manner fo...

Страница 5: ...ook Four Oil fired appliance system installation requirements Copies of British Standards may be purchased direct from BSI Customer Services 389 Chiswick High Rd London W4 4AL Tel 44 0 345 0869001 Int...

Страница 6: ...in an unheated garage should not exceed 3 meters and Should be lagged with water proof insulation to prevent freezing Boiler Sealed Condensate Drain Discharge Pipe 75mm Soak Away Lime Stone Chippings...

Страница 7: ...STANDARDS REGULATIONS Condensate Disposal Condensate Trap Fitting 1 Push washer into trap socket and screw trap onto boiler socket 2 Push flexible pipe onto trap socket 3 Final assembly Washer S S tr...

Страница 8: ...3 3 1 STANDARDS REGULATIONS Condensate Disposal System No 2 Condensate Pump Indent Order Condensate PUMP kit is available as an optional extra 8...

Страница 9: ...B C D K F F L N O P H J Boundary Boundary F Q Q Q Q Q Q Q R Pressure Jet Location Appliance Burner Type Condensing UK A Directly below an opening airbrick opening window etc 1000mm B Horizontally to a...

Страница 10: ...or low level flue and low level balanced flue discharge when tested to BS EN 303 1 5 Terminating positions must be at least 1 8m distant from a fuel storage tank unless a wall with at least 30 minutes...

Страница 11: ...disperse vapours 3 The effect of the moisture generated must be considered in relation to the possible corrosion of metal parts it might reach and to the possible formation of ice on pathways in freez...

Страница 12: ...sing birdguard System 35 clamp plate System 35 clamp plate System 35 flexible liner suitable for condensing applications System 35 adaptor 500mm Adjustable length Boiler adaptor Condensing boiler Cond...

Страница 13: ...ax length 6m Overall length must take into account bends where 45 bend 0 5m length and 90 bend 1m length INSTALLATION INSTRUCTIONS SUPPLIED WITH ALL FLUE KITS Elbows 45 90 Adjustable extensions 305 42...

Страница 14: ...photocell has stopped a burner 1 Ensure that the gasket door is sealed correctly to the boiler 2 Ensure that the burner collar is in place If you see that the burner collar and surrounding area is ge...

Страница 15: ...allow household waste or hot ashes container in vicinity of oil storage tank or boiler flue outlet 15 Flexible Oil Pipe s Two flexible burner Diesel hoses are supplied with the boiler which must be w...

Страница 16: ...the event of the control thermostat failing and keeps the boiler safe The safety high limit thermostat will shut the boiler off and will require the limit button to be pushed to restart the boiler It...

Страница 17: ...ING The boiler thermostat control and safety system is not designed and must not be relied on to protect plastic pipe from overheating Additional measures must be incorporated into the system pipework...

Страница 18: ...e measured in bar equals static head of system measured in bar plus 0 3 Sealed Heating Circuit The system must comply with BS 7074 Part 1 and BS 5449 Part 1 with a maximum water temperature of 80 C A...

Страница 19: ...n Mains cold water is supplied through the boiler drain fill valve Heating Circuit This is the heating system including the boiler which is filled from the mains supply via a flex filling loop to a pr...

Страница 20: ...to operate the post purge function on the burner when applicable If a permanent live supply is not provided the burner will not operate Mains Burner Limit Lockout WIRING Electrical Supply The boiler a...

Страница 21: ...Condensing output range Weight kg Dimensions mm H W D A B C E F G I J K L C26 System Condensing 26kW 148 856 555 618 760 231 165 210 580 648 341 78 62 93 C35 System Condensing 35kW 151 856 555 618 760...

Страница 22: ...pocket ACC003PKT ACC003PKT 8 1 Condensate trap ACC000TRP ACC000TRP 9 1 Condensate hose ACC000FLX ACC000FLX 10 1 Heat deflector ACC000HTD ACC000HTD 11 1 Air hose ACC000SSH ACC000SSH 12 1 Control panel...

Страница 23: ...mm dia plastic pipe 22 mm dia plastic pipe Circulating Pump 25 60 25 60 Integral Expansion Vessel Normal Capacity 12 litres 12 litres Expansion Vessel Pre charge Pressure 1 bar 1 bar Low Pressure Wate...

Страница 24: ...the event of the control thermostat failing and keeps the boiler safe The safety high limit thermostat will shut the boiler off and will require the limit button to be pushed to restart the boiler It...

Страница 25: ...IPING The boiler thermostat control and safety system is not designed and must not be relied on to protect plastic pipe from overheating Additional measures must be incorporated into the system pipewo...

Страница 26: ...ure measured in bar equals static head of system measured in bar plus 0 3 Sealed Heating Circuit The system must comply with BS 7074 Part 1 and BS 5449 Part 1 with a maximum water temperature of 80 C...

Страница 27: ...on Mains cold water is supplied through the boiler drain fill valve Heating Circuit This is the heating system including the boiler which is filled from the mains supply via a flex filling loop to a p...

Страница 28: ...otection It is also required to operate the post purge function on the burner when applicable If a permanent live supply is not provided the burner will not operate WIRING Electrical Supply The boiler...

Страница 29: ...J A L E F G K B Model Systempac Condensing output range Weight kg Dimensions mm H W D A B E F G I J K L C26 Systempac Condensing 26kW 160 945 597 651 795 242 92 633 44 271 133 121 236 C35 Systempac C...

Страница 30: ...at pocket ACC003PKT ACC003PKT 8 1 Condensate trap ACC000TRP ACC000TRP 9 1 Condensate hose ACC000FLX ACC000FLX 10 1 Heat deflector ACC000HTD ACC000HTD 11 1 Pressure vessel ACC012PVL ACC012PVL 12 1 Insp...

Страница 31: ...es 24 litres Flue Indoor Boilers Balanced Flue Assembly 125 5 mm dia 125 5 mm dia Max Low Level Flue Length 1 5m 1 5m Max High Level Balanced Flue Length 6m 6m Heating System Sealed Fit in accordance...

Страница 32: ...done with the boiler in the condition it is going to be operating at that is if a balanced flue is installed the air hose is fixed on the burner In the case of a Slimline Heatpac ensure that the door...

Страница 33: ...lear of all foreign matter Refill the system and again vent at all points as described Examine the complete system for water leaks having pressurised it to 1 2 5 bar Correct any leaks then check opera...

Страница 34: ...leaks Draw off any accumulated water and sludge from the tank by opening the drain valve Turn off the diesel supply and remove the filter bowl then wash the element clean with diesel Fit a new element...

Страница 35: ...nt qualified engineer using the correct installation and test equipment must carry out installation and commissioning 5 This warranty does not cover special incidental or consequential damages injury...

Страница 36: ...Valve Location Condensate Trap where fitted Condensate Trap Piped to Drain Condensate Trap Primed Float and Condensate Trap in Place Check Flue Seals Deflector Plate and Baffles Graphite Door Seal and...

Страница 37: ......

Страница 38: ......

Страница 39: ......

Страница 40: ...e the specification of our products at any time and be without obligation to make similar changes in products previously produced MLOBNZEB000 For further information on Firebird products please contac...

Отзывы: