5.1 - POPULAR - TECHNICAL DETAILS & DIMENSIONS
Model Output
Weight
kg
Dimensions(mm)
Enviromax kW
(incl.
burner)
H
W
D
C
E
F
G
Popular C12-18
12-18
99
684 344 381 202 164 100 122 502
Popular C20
15-20
107
684 441 381 202 164 100 122 502
Popular C26
20-26
112
684 441 381 202 164 100 122 502
Popular C35
26-35
115
684 441 381 202 164 100 122 502
Popular C44
35-44
182
815 470 531 202 154 96 123 620
Popular C58
44-58
190
815 470 531 253 154 96 123 620
Popular C73
58-73
210
873 530 525 253 155 96 123 670
Popular C100
80-100
300
1052 625 745 253 139 112 130 832
Burner
depth
Front View
Side View
Top View
W
F
G
E
H
D
C
Use a copper pipe (not plastic) for a minimum of 1 metre off the boiler.
Boiler Model
C12/18
C20 + 26
C35
C44 + 58
C73
C100
Heat Output
kW
12-18
15-20/20-26
26-35
35-44/44-58
58-73
80-100
Max. BTU/h (‘000)
40-60
50 - 90
90-120
120-200
200-250
270-340
CONNECTIONS
Heating Flow
1” BSP
1” BSP
1” BSP
1
1
/
2
” BSP
1
1
/
2
” BSP
2” BSP
Heating Return
1” BSP
1” BSP
1” BSP
1
1
/
2
” BSP
1
1
/
2
” BSP
2” BSP
Drain Off Valve
1
/
2
” BSP
1
/
2
” BSP
1
/
2
” BSP
1
/
2
” BSP
1
/
2
” BSP
1
/
2
” BSP
Condensate Trap
22mm PLASTIC
22mm PLASTIC
22mm PLASTIC
22mm PLASTIC
22mm PLASTIC
22mm PLASTIC
WATER CONTENT
Boiler (Litres)
24
24
24
43.5
54
75
FLUE (Indoor Boilers)
Balanced Flue Assembly (mm)
125 (5”)
125 (5”)
125 (5”)
150 (6”)
180 (7”)
200 (8”)
Conventional Flue Assembly (mm)
100 id.
100 id.
100 id.
150 id.
180 id.
180 id.
Max. Low Level Flue Length (metres)
3
3
3
3
3
3
Max. High Level Flue Length (metres)
6
6
6
4
4
4
Max Vertical Level Flue Length (metres)
4
4
4
4
4
4
HEATING SYSTEM (SEALED)
Fit in accordance with BS 7074 Part 1, BS 5449, OFTEC standards and all other relevant legislation.
Preset Pressure Relief Valve 3 bar
MAINS WATER SUPPLY PRESSURE
Min. 1 bar - Max. 10 bar (for user comfort, we recommend pressure at tap to be between 2 and 5 bar).
Limescale excess: When over 150/200 ppm, fit appropriate scale reducer.
WATER SIDE RESISTANCE
20KW
26KW
35KW
Flow Rate To Give A Nominal Output At 10k Differential
Flow Rate Measured
(Kg h-1)
1642
2135
2874
Waterside Resistance
(mbar)
0.18
0.18
0.18
Flow Rate To Give A Nominal Output At 20k Differential
Flow Rate Measured
(Kg h-1)
870
1131
1523
Waterside Resistance
(mbar)
0.19
0.19
0.19
PRESSURE JET OIL BURNERS
RIELLO RDB 2.2 up to C44 & RIELLO RDB 4.2 up to C58 to C100
FUEL
C2 Kerosene
ELECTRICAL SUPPLY
230V AC 50Hz 5A
TEMPERATURE CONTROL
Boiler Central Heating Control
60˚C - 80˚C
Boiler Safety Limit
110˚C