Firebelly Firepod Скачать руководство пользователя страница 6

6

Operational problems

Blackened glass

• 

The wood is too damp. Only use wood stored for at least 12 months under cover and with a moisture level not exceeding 20% 

• 

Insufficient intake of air from the top air control. Open the top air control further. The air shield system is more efficient the 
more air is allowed to run over the glass panel.

• 

The stove is run at too low a temperature.

Smoke in the room when opening door

• 

Never open the door when there are high flames on the wood.

• 

Poor chimney performance - consult chimney sweep.

• 

Check the position of any fitted flue damper or stabiliser and make sure it is in the open position.

Uncontrollable combustion

• 

Damaged door seal. Fit new seal.

• 

If there is an excessive chimney draft - fit a draft stabiliser in the flue pipe - consult a chimney sweep.

External air intake option

This stove can be fitted with an external air intake kit to make it suitable for use in passive buildings. For further information contact Firebelly 

or you local dealer.

Figure 5

Содержание Firepod

Страница 1: ...burning tips theory 2 Running temperatures 3 Cleaning and Maintenance 3 INSTALLATION INSTRUCTIONS Building regulations 4 Positioning and Clearances 4 Chimney 4 Flue connection 5 External air intake op...

Страница 2: ...e has been allowed to die too low then the bottom air control can be opened to allow air to the base of the re in an attempt to revive it Do not run the stove with the door open Warning The external s...

Страница 3: ...m the stove reduce the air entering the stove via the air controls The re must be well established and the stove hot before a minimum combustion rate is atempted Note that if the air supply is restric...

Страница 4: ...h stove installation is unique and the operation of each stove is subject to many variables including the fuel used the size of the room chimney performance ventilaion As such the best operation of yo...

Страница 5: ...ations for more information on hearth requirements Clearances The minimum distance to combustible materials should be 500mm at the back of the stove and 150mm to the sides of the stove Adjacent walls...

Страница 6: ...he room when opening door Never open the door when there are high ames on the wood Poor chimney performance consult chimney sweep Check the position of any tted ue damper or stabiliser and make sure i...

Страница 7: ...aulty workmanship dur ing normal use of the stove The guarantee does not cover parts deemed to be replaceable in the normal usage of the stove These include Glass Door rope seal Fire Brick linings Lee...

Отзывы: