4.4.2 SPECIAL PRECAUTIONS FOR THE FIRE PRO-
TECTION OF ADJACENT COMPONENTS CON-
STRUCTED OF FLAMMABLE MATERIALS
1. A distance of at least 5 cm has to be maintained between built-in furniture
(e.g. cupboards) and the fireplace cladding.
2. A clearance of at least 1 cm is recommended for components with small
contact areas (wall, floor or ceiling cladding). Wallpapers are not considered
to be combustible construction materials.
3. A clearance of at least 80 cm must be maintained between the front and
sides of the firebox opening and all flammable fixtures or built-in furniture
units, unless stated otherwise in component-specific safety instructions.
The figure illustrates a typical installation situation showing a and
this applies for each fireplace unit.
H
bzw. H+300
min. 500
The figure illustrates a typical installation situation showing
a and this applies for each fireplace unit.
4. When arranging ventilated thermal radiation protection down both sides (S),
a distance of just 40 cm is sufficient. The ventilated distance to the radiant
heat protecting device must be (S) at least 2 cm.
Width of opening
40 cm
80* cm
2c
m
1 cm
5 cm
1
2
3
4
( S )
* The required minimum distance can vary depending on the model
2
3
4
40 cm
80* cm
1 cm
2c
m
80* cm
( S )
* The required minimum distance can vary depending on the model
please read under point 4.4.3
resp.
In addition, the area starting from the straight radiation area of the effective
firebox opening must be protected by 300 mm to the left and to the right (see
illustration).
Please discuss whether and how the chimney flank must be insulated in your
installation situation with your responsible stove fitter and the chimney sweep.