Installation of Optional Equipment
MANUAL BACK DRAFT DAMPER
OPTIONAL ACCESSORY #AM-MD12
Manual Back Draft Damper
The Back Draft Damper may be installed in either a vertical or hori-
zontal section of the 12" round hot air duct. It should be positioned as
close to the plenum opening of the Fire Chief as practical. Press the female
end of the damper over the Fire Chief Furnace collar or male end of the
duct pipe. When properly positioned, the arrows on the air flow decal point
"away"
from the Fire Chief Furnace.
NOTE
: The back draft damper handle closes off the duct, stopping the cool
air from your air-conditioner from flowing back thru the furnace. Diagrams
below show horizontal and vertical installation.
OPEN THE DAMPER AT
THE BEGINNING OF HEATING SEASON - IF THE DAMPER IS IN THE
“CLOSED” POSITION, IT WILL CAUSE THE BLOWER TO RUN CON-
TINUOUSLY AND CAUSE THE FURNACE TO OVERHEAT CAUS-
ING THE BLOWER TO FAIL.
INSTALLING HOT WATER COIL
OPTIONAL ACCESSORY PART #TB-24S Water Coil with Hole Saw
1. Drill two one inch holes at the rear of the furnace just above the firebrick
using the coil as a template with the hole saw provided in the Water Coil Kit.
2. Place one nut on each end of the water coil and thread each as far as
they will go.
3. Open the loading door and insert the coil through the holes at the end of
the firebox just above the firebrick.
4. From the rear of the furnace, thread on the remaining two nuts and
tighten securely.
5. Have a qualified plumber connect your domestic hot water pipe to the
coil with the appropriate fittings.
REAR WALL OF FIREBOX
DOMESTIC HOT
WATER COIL
TURN INSIDE NUTS UP
TO END OF THREADS
HORIZONTAL INSTALLATION
VERTICAL INSTALLATION