5
FIRE CHIEF FURNACE
FIRE CHIEF FURNACE
FIRE CHIEF FURNACE
FIRE CHIEF FURNACE
FIRE CHIEF FURNACE
Assemble the Filter Box using
the screws provided.
NOTE
:
the side with the 1" hole in the
corner must be mounted to the
right side of the unit.
Attach Fan Limit with
3 - #10 screws in the
holes provided.
Secure the flex conduit
to the side of the furnace
using the clip provided
(requires one screw).
Mount the Forced
Draft Blower with
3 - 1/4-20 X 1/2"
bolts provided.
Attach the Fan Center us-
ing the 4 screws provided
on the 4X4 Junction Box.
NOTE
: follow the wiring dia-
gram on
page 6.
Mount the 4X4
Junction Box with
2 - #10 screws
provided.
Attach Filter Box using
6 - #8 self-tapping
screws.
Attach conduit from 2X4
Junction Box to the right
side of the filter box. Run
the blower wire thru the
conduit into the junction
box.