![FIP FLS F6.61 Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/fip/fls-f6-61/fls-f6-61_manual_2290595018.webp)
18
ORDERING DATA
Part No.
Version
Power
supply
Length
Main wetted
materials
Enclosure
Flow Rate
Range
Weight
(gr.)
F6.61.01
Hot-tap
12-24
VDC
615mm
304 SS/
PVDF/316L SS
IP65
0.05 to 8 m/s
(0.15 to 25 ft/s)
6000
Part No.
Name
Description
Weight
(gr.)
F6.KC1
Magmeter
Compact
mounting kit
Plastic adapter with compact cap and locking nut
137
M9.SP4.1
PG 11
PG 11 complete cable gland (2 o-rings and cap)
12
F1.SP3
Isolation Valve
2" Brass Ball Valve
1800
F1.SP5
Isolation Valve
1 1/4" Brass Ball Valve
1800
F1.SP6
2" to 1 1/4"
Reduction
Zinc Plated Steel 2" BS male to 1 1/4" BS female
405
F1.SP7
2" to 1 1/4"
Reduction
Zinc Plated Steel 2" NPT male to 1 1/4" BS female reduction
405
F6.60M.
SP1.S
Electronic device
Magmeter electronic device with 4-20mA output and freq.
Output /volumetric pulse output
180
F3.61M.
SP01
Magmeter flow
sensor for Hot
Tap installation
304 SS/PVDF body
1000
SPARE PARTS
Correction formula for K-Factor calculation according to real internal
diameter:
K-Factor_NEW = (K-Factor x ID²) / ID_NEW²
ID = Value in the table for the internal diameter (in mm)
ID_NEW = New value for the real internal diameter (always in mm)
K-Factor = Value in the table
K-Factor_NEW = New K-Factor value for the specified internal diameter
Example:
Nominal Pipe Size (DN) = 100 mm
New Internal Diameter = 104 mm
Forumla: K-Factor_NEW = (51.02 x 100²) / 104² = 20,52