Smoke

 

detector

 

 

Anti-theft device 

The

 

integrated

 

anti

theft

 

device

 

is

 

made

 

to

 

avoid

 

thefts

 

(in

 

group

 

housing

 

for

 

ex).

 

Break

 

the

 

2

 

nicks

 

(see

 

location

 

below),

 

the

 

detector

 

can

 

be

 

locked

 

and

 

blocked.

 

If

 

needed,

 

you

 

can

 

activate

 

the

 

lever

 

of

 

the

 

mechanical

 

lock

 

situated

 

through

 

the

 

opening

 

on

 

the

 

base

 

(see

 

below).

 

 

Commissioning the battery 

You

 

can

 

use

 

the

 

tab

 

to

 

disconnect

 

the

 

internal

 

battery.

 

1.

 

Remove

 

the

 

tab

 

by

 

pulling

 

it

 

(towards

 

you).

 

After

 

20

 

seconds,

 

the

 

detector

 

is

 

commissioned

 

(see

 

below

 

on

 

the

 

left).

 

2.

 

Put

 

the

 

key

 

away

 

in

 

the

 

location

 

space

 

provided

 

(see

 

below

 

on

 

the

 

right).

 

At

 

the

 

end

of

life

 

of

 

the

 

detector,

 

you

 

can

 

disconnect

 

the

 

battery

 

using

 

the

 

tab

 

to

 

stop

 

the

 

default

 

sound

 

signal

 

and

 

avoid

 

any

 

electric

 

risk

 

when

 

recycling

 

(see

 

Closure

 

of

 

the

 

detector).

 

 

Mounting the detector 

1.

 

Present

 

the

 

detector

 

on

 

its

 

base.

 

2.

 

Turn

 

clockwise

 

until

 

it’s

 

locked.

 

If

 

the

 

test

 

button

 

isn’t

 

adjusted

 

towards

 

the

 

entrance

 

of

 

the

 

room,

 

you

 

can

 

unlock

 

it

 

(anti

clockwise)

 

to

 

make

 

it

 

do

 

half

 

a

 

spin.

 

3.

 

Push

 

the

 

test

 

button

 

to

 

check

 

its

 

functionning.

 

 

 

Содержание CALYPSO-II

Страница 1: ...Smoke detector Datasheet CALYPSO II Smoke detector ...

Страница 2: ... GENERAL CHARACTERISTICS supply lithium battery non replaceable autonomy 10 years smoke detection by light diffusion sound power 85dB at 9 and 10 battery light and sound signal in case of default battery test frequency automatic about every 50 seconds mounting screws and rawplugs supplied for unperforated material protection against false alarm protection grid against insects with algorithm handle...

Страница 3: ...cur garage kitchen see Implementation precaution Avoid installing detectors in the bathroom Examples minimal protection advice optimal protection implementation precaution Flat House To install a detector in the garage or the kitchen please see Implementation precaution INSTALLATION ON THE CEILING OR ON THE WALL Example Respect the minimal distances indicated below Long corridor In more than 10 me...

Страница 4: ...and of a rapid clogging of the detector Respect a minimum distance of 2 meters for a minimum 9m surface from any device generating smoke or vapour Below 9m installing a detector in the kitchen is banned Use the neutralization device whenever you use a device generating smoke or vapour Example INSTALL AND COMMISSION ONE DETECTOR Necessary tools and pre requisite Drilling machine bit 4mm screws and ...

Страница 5: ...ng it towards you After 20 seconds the detector is commissioned see below on the left 2 Put the key away in the location space provided see below on the right At the end of life of the detector you can disconnect the battery using the tab to stop the default sound signal and avoid any electric risk when recycling see Closure of the detector Mounting the detector 1 Present the detector on its base ...

Страница 6: ...tton for 2 sec After the test sound signal 3 short beeps can be heard This confirm the neutralization Put a neutralized detector back in commissioning You can cancel the neutralization before the 10 minutes 1 Neutralized detector 1 red flash every 7 sec in presence of smoke 2 Press the test button 2 short beeps indicates that the neutralization has been taken into account 3 Detector is back to sta...

Страница 7: ...h 1 long beep 50 sec battery default main power supply see instructions above TEST With the test button We recommended to test the functionning of the detector once a week Briefly push the test button less than 2 sec The test button flashes red and emits a sound signal Use this test as a chance to acquaint your children with the alarm signal and to explain them what to do if a fire occurs in your ...

Страница 8: ... CEE directive relative to construction products NF mark The NF mark affixed on this product guarantees constant safety and quality controlled by specialists With its strict and exhaustive controls owner quality management system manufacturing controls audit monitoring tests it brings the consumer all guarantees of compliance to certified products The NF DAAF mark complies with the certification r...

Отзывы: