24
CLEANING AND MAINTENANCE
DAILY
1. Cleaning the HydroSeeder
®
:
A. Fill slurry tank to center of agitator shaft with clean water.
B. With the engine running and the hydraulics system turned on, move agitator lever
to full speed (forward or reverse) to flush off inside of tank top and walls.
C. Remove discharge nozzle and coupler gasket from remote valve coupler at the end
of the discharge hose.
D. With the engine at low idle and while aiming discharge hose or boom toward an
open area, open discharge and / or remote valve and engage (turn on) the slurry
pump. Allow to discharge until clear water is coming out.
E. Increase the engine RPMs to increase the water flow.
F. Open the recirculation valve and allow to run until the stream is clear.
G. Disengage (turn off) the pump clutch, idle the engine, move discharge valve
handles to OPEN position, move agitator handle to NEUTRAL, and turn off the
engine.
H. Remove drain plugs and allow tank to drain.
I. In freezing weather, leave main tank drain plug out and remove pump drain plugs.
Move all slurry valves to open position.
J. Wash the outside of HydroSeeder
®
to remove any corrosive materials.
K. Replace coupler gasket before reinstalling discharge nozzle onto remote valve
coupler.
2. Lubricating the HydroSeeder
®
(see LUBRICATION AND FLUIDS section):
Lubrication should be performed IMMEDIATELY AFTER cleaning of
the equipment, making sure the engine is not running. Failure to
comply could result in minor or moderate personal injury. Failure to comply could also
result in product or property damage.
A. Lubricate agitator shaft bearings located on the outside-front and rear of slurry
tank.
B. Service automatic pressure lubricator on slurry pump as needed.
C. Check engine oil and replenish when necessary. Change oil and filter after first 5
hours, then every 100 hours thereafter. Consult the engine operator’s manual for
correct grade of oil and engine break-in procedure.
NOTE:
Change engine oil and filter at least once annually even if the 100 hours
have not been met.
D. Lubricate swivels on discharge boom assembly.
E. Check the hydraulic oil level in the hydraulic oil reservoir; maintain level with the
sight gauge.
WEEKLY OR EVERY 40 HOURS OF OPERATING TIME
1. Clean air cleaner following the instructions in the engine operator’s manual.
2. Lubricate all points on HydroSeeder
®
as outlined in DAILY in CLEANING AND
MAINTENANCE section. Additionally, lubricate the grease fittings on clutch / pump.
3. Inspect slurry tank for buildup of residue in suction area and clear if necessary.
Содержание HydroSeeder T75S
Страница 2: ...FOR OFFICE USE ONLY DATE UPDATE DESCRIPTION CODE 09 29 16 Initial release MN0929 ...
Страница 4: ......
Страница 39: ...33 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 40: ...34 6 1 4 5 2 7 9 2 8 3 10 9 Figure 7 Lubrication and Adjustment Points ...
Страница 42: ...36 Hydro Seeder T75 13 ft 8 in 417 cm 8 ft 4 in 254 cm 5 ft 9 in 175 cm ...
Страница 44: ...38 38 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 56: ...T75 CE MN0929 50 WHEN ORDERING PARTS BE SURE TO STATE SERIAL NUMBER OF MACHINE 1 2 3 4 5 7 6 8 9 10 11 12 ...
Страница 66: ...T75 CE MN0929 60 WHEN ORDERING PARTS BE SURE TO STATE SERIAL NUMBER OF MACHINE 1 2 3 ...
Страница 70: ...T75 CE MN0929 64 WHEN ORDERING PARTS BE SURE TO STATE SERIAL NUMBER OF MACHINE CONTROL PANEL WIRING ...