REMOTE CONTROL TROUBLESHOOTING 

GUIDE (MODELS BB302 AND MB50) 

STEP 1

If none of the LEDs illuminate at all, check the batteries 
fi rst.

Install new batteries. Pay attention to the diagram inside 
the battery compartment.

Batteries 

ARE NOT

 arranged in typical “up, down, up, 

down” order.

If lights do not come on after replacing batteries and 
restarting the remote, return the remote for service.

Troubleshoot Remote

STEP 2

Remote has power, but LEDs are fl ashing in repeating pattern.

TX

 and 

RX

 fl ash together fi rst; then 

Error Light

 and 

Battery Light

 

fl ash together.

Holding the green power button on the back of the remote too long 
can cause this to happen. Let go of the green power button and see 
if the problem goes away.

This error can also indicate a switch is stuck. Check all switches on the remote are in the center position. 
Move all switches up and down and release.

If the problem continues after checking all switches, return the remote for service.

STEP 3

Remote has power, but LEDs are fl ashing in repeating pattern.

TX

 and 

Error Light 

fl ash together fi rst; then 

RX

 and 

Battery Light

 

fl ash together.

This error indicates the E-Stop button on the remote is not in the “up” 
position. Release E-Stop by rotating red button gently clockwise. If 
button “pops” up, retry powering up the remote (

First Step - Turn the 

Remote On

).

If the problem continues after E-Stop is in the “up” position, return the remote for service.

Содержание Bark Blower BB302

Страница 1: ...ould eliminate the problem Use this guide first before returning the remote to Finn Most malfunctions can be eliminated through the solutions provided After attempting to use this guide to fix the pro...

Страница 2: ...on the back of the remote too long can cause this to happen Let go of the green power button and see if the problem goes away This error can also indicate a switch is stuck Check all switches on the...

Страница 3: ...ing green once per second HEALTH LED is LED 3 NO If the HEALTH LED is out or is lit steady the main microcontroller has stalled If the HEALTH LED is flashing rapidly there is a memory fault with the r...

Страница 4: ...ES Check can bus wiring to keypad controller If the can bus wiring is damaged repair wiring If the wiring is okay replace the keypad Return to STEP 2 STEP 4 Is the TX RX light on the receiver flashing...

Страница 5: ...flashing amber amber TX RX LED is LED 4 The TX RX LEDs on the remote are flashing but the remote is not controlling the machine If NO part of the machine can be controlled Check supply voltage Is the...

Страница 6: ...valve coil returns and any other output load returns are tied to the same point and that point is tied to battery negative and the VDC ground pin on the receiver REMOTE CONTROL TROUBLESHOOTING GUIDE M...

Страница 7: ...one or more output channels Possible solution s Check wiring for broken connections Check hydraulic valve coils for continuity typical valve coil resistance is 25 Ohms or less Swap connectors from sus...

Страница 8: ...control s radio signal Disassociate and reassociate the remote and receiver This will allow the remote to scan the radio channels that it can operate on and determine the best channel to work with If...

Отзывы: