background image

 

 
 
 

1. 

Use in a well-ventilated site by using spray both. 

If not, poor ventilation can cause organic solvent poisoning and catch fire. 

2. 

Always wear protective gear (safety glasses, mask, gloves) 

If not, cleaning liquid, etc., can cause inflammation of eyes and skin. 
If you feel something wrong with eyes or skin, immediately see a doctor. 

3. 

Wear earplugs if necessary. 

Noise level can exceed 85dB(A), depending on operating conditions and painting site. 

4. 

If operators pull the trigger many times during operation, it may cause carpal tunnel syndrome. 

Be sure to take a rest if you feel tired. 

 
 
 

1. 

Never alter this spray gun. 

If done, it can cause insufficient performance and failure. 

2. 

Never spray foods or chemicals through this gun. 

If done, it can cause accident by corrosion of fluid passages or adversely affect health by mixed foreign matter. 

3. 

If something goes wrong, immediately stop operation and find the cause. 

Do not use again until you have solved the problem. 

How to connect 

CAUTION

 

 

Use clean air filtered through air dryer and air filter. 

If not, dirty air can cause painting failure. 

 

When you use this gun for the first time after purchasing, adjust fluid needle packing set. 

Due to this gun’s unique no rubber o-ring design, it is normal that the needle packing may be a little bit overtight or loose after a 
period of not using it. 
To fix it, please just slowly tighten fluid packing seat and loosen a bit when fluid needle set does not return smoothly, and adjust 
so that fluid needle set smoothly moves. 

 

If you use this gun for the first time after purchasing, to remove rust preventive oil inside, it is suggested to 

manually

 

clean the fluid passages by spraying thinner and carefully clean air cap, nozzle and needle with brush and thinner.

 

If not, remaining preventive oil can cause painting failure such as fish eyes.   
Washing machine may not be able to get the gun cleaned completely.   

 

  Firmly fix hose or container to spray gun. 

 

If not, disconnection of hose and drop of container can cause bodily injury. 

 

  Use an air hose with minimum 9mm inner diameter. 

Depending on hose length, larger I.D. hose may be required.

 

1. 

Connect an air hose to air nipple tightly. 

2. 

Connect a fluid hose or a container to fluid nipple tightly. 

3. 

Flush the gun fluid passage with a compatible solvent. 

4. 

Insert the filter into the fluid inlet of gunbody. Make sure the body of the filter is pushed fully so the body of the filter does not protrude from 
the cup insert. 

5. 

Attach the Gravity Cup to the fluid inlet, pour paint into container, test spray and adjust fluid output as well as pattern width. 

If the finish is too dry, reduce airflow by reducing air inlet pressure. If finish is too wet, reduce fluid flow by  turning fluid adjusting knob 
clockwise. 
If atomization is too coarse, increase inlet air pressure. If too fine, reduce inlet pressure. 

How to operate 

1. 

The recommended air inlet pressure 2.0bar/29psi for LVMP (MP). Do not use more pressure than is necessary to atomise the material 
being applied. Excess pressure will create additional overspray and reduce transfer efficiency. 

2. 

Recommended paint viscosity differs according to paint property and painting conditions, 18±2 sec./ DIN4 cup is recommendable.   

3. 

Keep fluid output as small as possible to the extent that the job will not be hindered. It will lead to better finishing with the atomization. 

4. 

Set the spray distance from the gun to the work piece within the range of 150-200mm (6-8in). 

5. 

The gun should be held so that it is perpendicular to the surface of the work piece at all 
times. Then, the gun should move in a straight and horizontal line. Arcing or tilting may result 
in uneven coating. 

 

 

Maintenance and inspection 

WARNING

 

 

First release air and pressure fully according to item No.3 of “Improper use of equipment” of WARNING on page 1.

 

 

Tip of fluid needle set has a sharp point. Do not touch the tip of needle valve at the maintenance.

 

 

Be careful not to damage the tip of fluid nozzle.

 

 

Only an experienced person who is fully conversant with the equipment can do maintence and inspection.

 

Protection of human body 

Other precautions 

Отзывы: