NOTE:  All GP Series pumps use PVDF Impellers. 

Item

Description

Part No.

1

I

mpeller Housing

Polypropylene NPT

M100101-1

PVDF NPT

M100101-2

Polypropylene BSP

108173-1

PVDF BSP

108173-2

2

Housing Cover

Polypropylene

M100109-1

PVDF

M100109-2

3

Impeller

2-1/2", PVDF - for bellows/multispring seal models          

A101705-3

3", PVDF - for bellows/multispring seal models

A101705-8

3-1/2", PVDF - for bellows/multispring seal models

A101705-2

4", PVDF - for bellows/multispring seal models

A101705-7

4-1/2", PVDF - for bellows/multispring seal models

A101705-1

2-1/2", PVDF - for double seal models

A101705-6

3", PVDF - for double seal models

A101705-10

3-1/2", PVDF - for double seal models

A101705-5

4", PVDF - for double seal models

A101705-9

4-1/2", PVDF - for double seal models

A101705-4

5

Cooling/Press Collar

 (std for double seal, optional for bellows/multispring seals)

Polypropylene 

M100112

6

Motor Adapter

NEMA 56C, 143/145TC

M101572-1

IEC 80 frame

M101572-2

IEC 90 frame

M101572-3

7

Seals 

(standard options - contact factory for additional options)

Bellows - C/R/V

J100108

Multispring - C/RH/V

J100109

Double - C/RH/V,C/RH/V

J100110

8

Retaining Ring

Stainless steel

J100111

9

Hex Bolt

Stainless steel (6 required)

J100112

10

Flat Washer

Stainless steel (6 required)

J100113

11

Hex Bolt

NEMA 56C - stainless steel (4 required)

J100114

IEC 80 frame - stainless steel (4 required)

J103780

IEC 90 frame - stainless steel (4 required)

J103662

Item

Description

Part No.

12

Lock Washer

NEMA 56C - stainless steel (4 required)

J100115

IEC 80 frame - stainless steel (4 required)

J100672

IEC 90 frame - stainless steel (4 required)

J102282

14

Housing O-ring

FKM

J100116

EPDM

J100117

15

Cooling Collar O-ring

 

(std for double seal, optional for bellows/multispring seal)

FKM

J100118

EPDM

J100119

17

Cooling Collar Seal

Lip seal - for bellows and multispring seal models only     

J100120

18

Slinger Ring

Neoprene

M100115

20

Shaft Adapter with Set Screws

NEMA 56C

A100856

NEMA 143TC, 145TC

A100857

IEC 80 frame

A100859

IEC 90 frame

A100860

20A

Set Screw

Cap point, stainless steel (4 required)

J100220

21

Cooling Collar Assembly 

(for bellows & multispring seals models)

w/ FKM o-ring & lip seal

A100185

22

Protective Guard

Left side

M101637-1

Right side

M101637-2

23

Guard Shroud Screw

Stainless steel

J100932

*

Restrictor Bushing

TFE (use with bellows seal and item 5 &15)

M100346

*

Pipe Plug

1

/8”, 316SS - for use w/ restrictor bushing option

J103312

  5

Содержание GP11 Series

Страница 1: ...e four set screws from the shaft adapter onto the motor shaft d Remove the two temporary hex head cap screws and shim washers 4 Pull the motor adapter flush against the motor face Install GP11 SERIES Sealed Non Metallic Centrifugal Pumps Installation and Maintenance Instructions four hex head cap screws and flat washers through the motor adapter and into the motor and tighten 5 Verify there is a 0...

Страница 2: ...n Refer to the directional arrow on the pump if needed NOTE A pump running backward will run but at a greatly reduced flow and pressure OPERATION FLOODED SUCTION SYSTEMS 1 Fully open the suction and discharge valves 2 If a cooling collar is used turn on the cooling water 3 Start the pump and verify liquid is flowing If there is no liquid flow refer to the Troubleshooting section of these instructi...

Страница 3: ...with a rubber lubricant emulsion or soapy water b Carefully slide the housing cover over the Impeller s shaft The side of the housing cover with the pressed in seal face should be away from the impeller c Separate the rotating head of the seal from the large spring Relubricate the impeller s shaft then carefully slide the rotating head of the seal over the Impeller s shaft using a twisting motion ...

Страница 4: ...tor adapter While holding the cooling collar against the housing cover install the assembly into the motor adapter The motor adapter will hold the cooling collar in place It will now be necessary to hold the impeller to keep the seal s spring compressed 5 Carefully place the assembly in position to the motor s face a Screw the impeller onto the motor shaft or shaft adapter Use a drop of Blue 242 L...

Страница 5: ... RH V J100110 8 Retaining Ring Stainless steel J100111 9 Hex Bolt Stainless steel 6 required J100112 10 Flat Washer Stainless steel 6 required J100113 11 Hex Bolt NEMA 56C stainless steel 4 required J100114 IEC 80 frame stainless steel 4 required J103780 IEC 90 frame stainless steel 4 required J103662 Item Description Part No 12 Lock Washer NEMA 56C stainless steel 4 required J100115 IEC 80 frame ...

Страница 6: ...to in whole or in part accident overload abuse chemical attack tampering or alteration The warranty does not apply to any other equipment used or purchased in combination with this product The manufacturer accepts no responsibility for product dam age or personal injuries sustained when the product is modified in any way If this warranty does not apply the purchaser shall bear all cost for labor m...

Страница 7: ...is valid provided that the devices are fully assembled and no modifications are made to these devices Type of Device Centrifugal Pumps Models AC AK AV 400 500 600 800 GP 11 22 32 VKC 5 5 6 6H 7 8 10 DB 3 4 5 5 5 6 6H 7 8 9 10 11 15 22 MSKC SP 10 11 15 22 KC 3 4 5 5 5 6 6H 8 10 11 22 32 MSVKC UC 1516 1516L 1518 1518L 2110 3158 326 326H 328 436 438 4310H 326H 4310H 6410 EU Directives Machinery Safet...

Отзывы: