Back Plate

4 feet / 1.2 meter

(recommended)

TA200 Plus

TCP/IP PORT (LAN)

USB PORT

POWER 

ADAPTER PORT

Step 1

Determine the Location and Positioning 

of the Installation

•  

Avoid installing the terminals in locations that has contact with 

a strong light source (e.g direct sunlight, spotlight, fluorescent 

light, etc)

• 

Avoid installing the terminals in locations with high moisture or 

condensation levels in the air

• 

The recommended installation height of the terminal from the 

ground is 1.2 meter. 

Step 2

Mounting of Terminals

A. Mount on WAll

•  

After  determining  the  height  of  the  terminal  from  the  ground 

level  and  have  made  the  relevant  marks  on  the  wall,  drill  the 

screws into the wall to hang the back plate. 

  Refer to Appendix II for dimensions and measurements of instal-

lation.

Installation Guide

TA200 Plus

Fingerprint Color Multimedia for 

Time Attendance System

b. Flexi- Kit

FingerTec offers flexi-kit for all its time attendance models. Attach 

the terminal on the flexi-kit for convenience.

Step 3

Wiring for Power Supply

The  power  jack  is  positioned  at  the  rear  of  the  terminal,  labeled 

Power Adapter Port in the below diagram.

Step 4

Setting Up Data Communications 

 (Skip this step if you are using USB flash disk to transfer data)

TCP/IP – LAN Connection

For TCP/IP connection, plug the special RJ45 jack into the TCP/IP 

(LAN)  Port  of  the  terminal.  Connect  the  other  end  (normal  RJ45 

jack) to the local area network hub or a PC. Configure the device ID, 

IP address, subnet mask and Gateway in the terminal (refer to the 

hardware user manual for details). 