background image

m-Kadex

Step 1

Determine the Location and Positioning 

of the Installation
• 

Avoid installing the terminals in locations with high moisture or 

condensation levels in the air

• 

The recommended installation height of the terminal from the 

ground is 1.2 meters. 

Step 2

Mounting Terminals on a Wall

•  

After  determining  the  height  of  the  terminal  from  the  ground 

level  and  have  made  the  relevant  marks  on  the  wall,  drill  the 

screws into the wall to hang the back plate. 

  Refer to Appendix II for dimensions and measurements of instal-

lation.

Step 3

Wiring for Power Supply

The power input ports for these models are located at the rear of 

the terminals. There is no adapter plug supplied with the models, 

instead you need to source for power cables (red and black cables) 

to connect the power from the terminal to the AdapTec.

J7
AL-
AL+
NC
COM
NO
BUT
GND
SES
BELL+

BELL-

J2
RJ45-1
RJ45-2
RJ45-3
RJ45-6
J12
WDO
WD1
GND
RXD
TXD
GND
485A
485B

G

N

D

+1

2V

V3.6 - 09032

J1

USB 

Port

Back Plate

4 feet / 1.2 meter

(recommended)

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

BEEP

GLED

RLED

INWD0

INWD1

GND

+12V

Wiegand

IN

Power

OUT

3rd party 

controller with 

26-bits wiegand 

output

RJ45-1

RJ45-2

RJ45-3

RJ45-6

WD0

WD1

GND

RXD

TXD

GND

485+

485-

TCP/IP

Wiegand

OUT

RS232

RS485

3rd party controller

with 26-bits wiegand 

input

RS232 

cable

TCP/IP

RX+

RX-

1. RS485 Single Connection

RS232/RS485 

Data Converter

485B

485A

RX+

RX-

RS232/RS485 

Data 

Converter

2. RS485 Network Connection

485B

485A 

485B

485A

GND

+12V

DC12V 3A

Power 

Supply

Door Lock connector. 

Refer to Appendix I

Installation Guides

w w w . f i n g e r t e c . c o m

m-Kadex & k-Kadex

Card Reader for Time Attendance &

Door Access Control System

Отзывы: