7
5. Scope Of Application
Scope
The product is designed based on food grade structure and materials, ideal for food
and health areas.
Suitable for level detection of powder or granular medium as a switch output.
Can be used for liquid with separate layers (such as bubbles) and two-level or interface
detection (such as oil + water).
Can be used for almost all media; low specific gravity, low dielectric, non-conductive
media can all work properly.
Limitations
Not suitable for bulk solid or rough material (such as quartz sand).
Not suitable for highly corrosive media (strong acids and strong alkaline). Please check
the compatibility with the product material first.
6. Ambient Conditions
Standard type
Storage temperature: -40°C ~ 85°C (-40°F ~ 185°F)
Ambient temperature:-40°C ~ 80°C (-40°F ~ 176°F)
Medium temperature:-40°C ~ 100°C (-40°F ~ 212°F)
Power supply: 12 VDC ~ 30 VDC
Output load current: Max. 50 mA
Rear install type
Storage temperature: -40°C~85°C (-40°F~185°F)
Ambient temperature: -40°C~80°C (-40°F~176°F)
Medium temperature: -40°C~80°C (-40°F~176°F)
Power supply: 12 VDC~30 VDC
Output load current: Max, 50 mA
Содержание SIS2
Страница 10: ...10 9 External Dimensions 9 1 Dimensions...