Finelite HP-6 Recessed Flush Diffuser Tech Zone 6

Protected by one or more US Patents: 8915613; D702,391; D702,390; D700,732; D727,554 S; D727,550 S, D727,551 S

© 2017 FINELITE, INC. ALL RIGHTS RESERVED.   Form 98383 V2.   04/17

HP-6 Recessed Flush Diffuser Tech Zone 6" T-Bar 

Joiner/Ender 

Installation Instructions

Note: All power connections to be installed to local/national codes  

         by a Certified Electrician.

Finelite, Inc.  •  30500 Whipple Road  •  Union City, CA 94587-1530  •  (510) 441-1100  •  Fax: (510) 441-1510  •  www.finelite.com

1

Step 1

Step 2

Remove diffuser from joiner/ender and set aside to prevent it from getting dirty or damaged. NOTE: If part of a longer run, diffuser will 

be reinstalled back into original luminaire section as lengths vary.

Install joiner/ender onto ceiling next to starter. 

0 - 10V

Dimming

Scan QR code for

helpful video(s)

Joiner/Ender

Diffuser

Starter

Joiner/Ender

Secure to Structure

(by others)

Step 3

Install T-Bar brackets onto joiner/ender luminaire. Secure with #8-18 x 1/4" screws (provided). Secure luminaire to structure using tie-wire 

(by others), as per code. 

Remove backplate clips to release the backplates. We recommend using a flat head screwdriver to remove them.

CAUTION: Do not lose these pieces. 

Step 4

Joiner/Ender

Starter

T-Bar Bracket

Joiner/Ender

Secure to 

Structure

(by others)

#8-18 x 1/4" Self Drilling 

Screws (Provided)

Backplate Clips

4"

6"

Center-to-Center

T-Bar Spacing

9/16" Tech Zone 6"