Fine Offset Electronics WH40B Скачать руководство пользователя страница 2

2

Contents

1. Introduce

.....................................................................

3

2. Get Started

.................................................................

3

2.1 Parts List

...........................................................

3

2.2 Recommend Tools

..........................................

4

2.3 Installation

........................................................

4

2.4 Mount outdoor sensor

....................................

8

3. Console Operation

..................................................

11

3.1 Normal Mode

.................................................

12

3.2 SET Mode

......................................................

13

3.3 Rain History Mode

........................................

14

3.4 MIN/MAX Mode

.............................................

15

3.5 HI/LO Alarm Set Mode

.................................

15

3.6 Factory Reset/Clear Memory

......................

16

4. Function

....................................................................

17

5. Maintenance

............................................................

18

6. Troubleshooting Guide

...........................................

19

7. Specifications

...........................................................

22

8. Liability Disclaimer

..................................................

23

9. FCC Statement

........................................................

23

10. Warranty Information

............................................

25

Содержание WH40B

Страница 1: ...1 High Precision Digital Rain Gauge with Indoor Temperature and Humidity Model WH40B...

Страница 2: ...sor 8 3 Console Operation 11 3 1 Normal Mode 12 3 2 SET Mode 13 3 3 Rain History Mode 14 3 4 MIN MAX Mode 15 3 5 HI LO Alarm Set Mode 15 3 6 Factory Reset Clear Memory 16 4 Function 17 5 Maintenance 1...

Страница 3: ...of the rain gauge at their final destination please set up the rain gauge with all parts being nearby for testing the correct function Power up sequence must be performed in the order shown in this se...

Страница 4: ...e User Manual 2 2 Recommend Tools Hammer for installing remote transmitter rain collector 2 3 Installation Wireless Rain Collector Set Up 1 Rain collector 2 LED Indicator 3 Bubble level 4 Battery door...

Страница 5: ...ke sure the battery is inserted the correct way or a proper reset is happened Do not install the batteries backwards You can permanently damage the outdoor sensor Note We recommend lithium batteries f...

Страница 6: ...nsole Set Up 1 Rainfall data display 2 Rainfall grade graph 3 Rainfall of day week month year display 4 Time 5 Rain rate event 1h 24h display 6 Indoor temperature 7 Indoor humidity 8 Alarm icon 9 Date...

Страница 7: ...le stand 13 Battery door 2 Install the batteries The unit will turn on all segments of the LCD for 3 seconds after power on and display setting value Then the unit will start to register the outdoor c...

Страница 8: ...display 2 4 Mount outdoor sensor Mount with U bolts The mounting assembly includes two U Bolts and a bracket that tightens around a 1 to 2 diameter pole included a D32 H200mm stainless steel tube usin...

Страница 9: ...9 Note Use the bubble level beside the rain sensor as a guide to verify that the sensor is leveled Mount with screws The mounting assembly also includes two screws for installation on a flat place...

Страница 10: ...rriers We recommend the following best practices for trouble free wireless communication 1 Electro Magnetic Interference EMI Keep the console several feet away from computer monitors and TVs 2 Radio F...

Страница 11: ...hrough metal barriers such as aluminum siding If you have metal siding align the remote and console through a window to get a clear line of sight 3 Console Operation Program mode The screen is divided...

Страница 12: ...RAIN 2 display DAY WEEK MONTH YEAR TOTAL normal mode or programming mode HISTORY display history records return to normal mode HI LO display the MAX MIN value normal mode Set Alarm long press to ente...

Страница 13: ...te the display of Display rainfall of day Display rainfall of week Display rainfall of month Display rainfall of year Display rainfall of total Note Long press button RAIN 2 over 5s will clear the cur...

Страница 14: ...mm in Note In the setting mode press RAIN1 or RAIN2 buttons to change or scrolls the value Hold the button for 2 seconds can change fast The setting mode will return to normal display while idle 15s o...

Страница 15: ...estamp displayed The setting mode will return to normal display while idle 15s 3 5 HI LO Alarm Set Mode In Normal Mode long press the HI LO button for 2 seconds to enter Alarm Set Mode You can press t...

Страница 16: ...d the button for 2 seconds can change fast When the alarm value is reached the corresponding alarm icon will flash and the buzzer will ring for 2min The ringing can be stopped by pressing any button T...

Страница 17: ...second the unit will receive wireless rain sensor Rain1 record view RATE EVENT 1H 24H Rain2 record view DAY WEEK MONTH YEAR TOTAL Rain1 Rate Event 1h 24h rain data against graph display Rain Rate Eve...

Страница 18: ...Rotate the funnel counter clockwise and lift to expose the rain gauge mechanism and clean with a damp cloth Remove any dirt debris and insects If bug infestation is an issue spray the array lightly wi...

Страница 19: ...ilicon spray to prevent snow build up 6 Troubleshooting Guide Problem Solution Wireless remote outdoor unit not reporting in to console There are dashes on the display console Check the remote transmi...

Страница 20: ...play console and wait 10 seconds Put the batteries back in 3 Do not touch any buttons for several minutes 4 The remote sensor search icon will splash on the display Wait several minutes for this icon...

Страница 21: ...e not transmitting through solid metal like aluminum siding acts as an RF shield or earth barrier down a hill 5 Move the display console around electrical noise generating devices such as computers TV...

Страница 22: ...to 140 Accuracy 1 F 0 5 C Indoor humidity measure range 10 to 99 Accuracy 6 RH 25 C 30 RH to 80 RH Accuracy 5 RH 25 C 1 RH to29 RH 80 RH to 99 RH Power consumption Base Station 3xAA Alkaline batterie...

Страница 23: ...fety information The specifications of this product may change without prior notice This product is not a toy Keep out of the reach of children 9 FCC Statement Statement according to FCC part 15 19 Th...

Страница 24: ...instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful int...

Страница 25: ...ognized We provide a 1 year limited warranty on this product against manufacturing defects in materials and workmanship This limited warranty begins on the original date of purchase is valid only on p...

Страница 26: ...he product itself and does not cover the cost of installation or removal from a fixed installation normal set up or adjustments claims based on misrepresentation by the seller or performance variation...

Отзывы: