Fine Offset Electronics WH16H Скачать руководство пользователя страница 7

 

 

7

 
5.1 Quick Display Mode 

- While in Normal Mode, press the 

SET

 key to enter the Quick Display Mode as follow: 

1.  Outdoor Temperature / Wind chill / Dew point (press the 

+

 key or 

MIN/MAX

 key shifts the display 

between outdoor temperature, wind chill and dew point) 

2.    Absolute pressure / Relative pressure (press the 

+

 key or 

MIN/MAX

 key shifts the display between the 

absolute pressure and relative pressure) 

3.    Wind speed / Gust speed (press the 

+

 key or 

MIN/MAX

 key shifts the display between the wind speed 

and gust speed) 

4.    1 hour/ 24 hour / week/ month / total rainfall quantity (press the 

+

 key or 

MIN/MAX

 key shifts the display 

between the selectable rainfall quantities), while display the rainfall total quantity, pressing the 

SET

 key 

for 2s will reset the rainfall total value to zero and the time recording to current time

 

 
- Press the 

SET

 key to accept the change and advance to the next display mode. Continue to press the 

SET 

key to toggle through the display mode until return to the normal Mode 

 
 
5.2 Setting Modes 

 

-

 Press 

the 

SET

 key for 3 second while in normal mode to enter the normal Setting mode 

-

 Press 

the 

SET

 key to select the following setting in sequence : 

1.  Time Zone Setting 
2. DST on/off 
3.  12/24 hour format 
4.  Manual time setting (hours/minutes) 
5.  Calendar setting(year/month /date) 
6.  Temperature display unit degree Celsius or Fahrenheit 
7.  Air pressure display units in hPa or inHg 
8.  Relative pressure setting from 27.13inHg – 31.89inHg (default 29.93inHg) 
9.  Pressure threshold setting (default 3) 
10.  Storm threshold setting (default 5) 
11.  Wind speed and gust display units in km/h, mph, m/s, knots, bft 
12.  Rainfall display units in mm or inch 

-

 

In the setting modes, press 

+

 key or 

MIN/MAX

 key change or scrolls the value. Holding the 

+

 key or 

MIN/MAX

 key for 3 second will increase/decrease digits in great steps.   

-

 Press 

HISTORY

 key or key idle 30 second, the setting mode will return to Normal Mode 

 

Note: 

Please set the units firstly before change units’ value. During change of units setting, units’ value will 

change according to new units but it might cause resolution loss due to its internal calculation algorithm. 

Note:

 “DST OFF” indicates that the feature is off and the internal real time clock will not change times 

automatically. “DST ON” indicates that the feature is on and the internal real time clock will change times 
according to the DST time schedule automatically. Some locations (Arizona and parts of Indiana) do not 
follow Daylight Saving Time, and should select “DST OFF”. 
 
 

5.3 History Modes 

-

 

While in Normal Mode, press the 

HISTORY

 key to enter the History Mode.   

-

 

In the History Mode, press the 

+

 key to select the record over the past 24hours at increments of -3 hours, 

-6 hours, -9 hours, -12 hours, -15 hours, -18 hours, -21 hours, -24 hours 

-

 

Press the 

HISTORY

 key or key idle 30 second to return to Normal Mode

 

 

 

5.4 Alarm Modes 

-      While in Normal Mode press the 

ALARM

 key to enter the High Alarm Mode 

-   Press the 

ALARM 

key again to enter Low Alarm mode   

Remark

: after the initial pressing of 

ALARM

 key, the display will be refreshed to show current high, low alarm 

values. Normal alarm value will be displayed only for those already activated, all other not activated 
values will be displayed with “- - -“or “- -“instead.     

-   Press the 

ALARM

 key again to return the Normal Mode 

-      In the High Alarm Mode press the 

SET

 key to select the following alarm modes: 

Содержание WH16H

Страница 1: ...view 5 4 1 LCD overview 5 4 2 Weather forecast 6 4 3 Weather forecast tendency indicator 6 4 4 Storm warning indicator 6 5 Program modes 7 5 1 Quick display mode 7 5 2 Setting mode 7 5 3 History mode...

Страница 2: ...us user selectable Indoor and outdoor relative humidity displays Barometric pressure reading in inHg or hPa absolute or relative user selectable Detailed display of rainfall data in 1 hour 24 hours on...

Страница 3: ...s powered up a short beep will sound and all LCD segments will light up for about 3 seconds before it enters into learning mode to learn the sensors security code After the learning mode the base stat...

Страница 4: ...angerous chemicals and fumes 3 2 Mounting 1 Base station With one foldable leg at the back of the unit the base station can be placed onto any flat surface or wall mounted at the desired location by t...

Страница 5: ...isplay unit 9 General indoor alarm icon 10 MIN MAX information 11 Wind chill and dew point temperature display 12 Outdoor temperature and humidity display 16 Weather forecast icon 17 Weather tendency...

Страница 6: ...weather is changing weather tendency indicator animated arrows will be flashing And then the arrows will fix while weather conditions have become stably Examples of changing weather icons 4 4 Storm w...

Страница 7: ...ay units in km h mph m s knots bft 12 Rainfall display units in mm or inch In the setting modes press key or MIN MAX key change or scrolls the value Holding the key or MIN MAX key for 3 second will in...

Страница 8: ...ather condition doesn t meet the user set level Press any key to mute the alarm but the triggered source will continue to flash until weather conditions have become more steady This feature is useful...

Страница 9: ...steel concrete isolating aluminum foil and etc Find a different location for sensors and or receiver See also item transmission range below Interference from other sources e g wireless radio headset...

Страница 10: ...nstalled and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation...

Отзывы: